Kuntai Park

Mr. Kuntai Park

Morecular Imaging Research & Education (MiRe) Laboratory, Department of Electronic Engineering, Sogang University
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2022 in Nuclear Engineering and Technology
Verified
Journal Article
Open access
HLHyuntae Leem
Hyuntae Leem
YCYong Choi
Yong Choi
JJJiwoong Jung
Jiwoong Jung
Kuntai ParkKuntai Park
Kuntai Park
YKYeonkyeong Kim
Yeonkyeong Kim
JJJin Ho Jung
Jin Ho Jung

13 September 2021 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
JJJiwoong Jung
Jiwoong Jung
YCYong Choi
Yong Choi
Kuntai ParkKuntai Park
Kuntai Park
YKYeonkyeong Kim
Yeonkyeong Kim
JJJin Ho Jung
Jin Ho Jung
Multiplexing circuits in pixelated PET detectors are being studied with the goal of minimizing the degradation of detector performance. The purpose of this study was to develop a diode-based symmetric charge division (SCD) circuit with reducing the crosstalk caused by the leakage currents of adjacent channels connected in rows and columns. Four different SCD circuits (diode-based SCD with grounding path, diode-based SCD, resistor-based SCD with grounding path, and resistor-based SCD) were constructed and their performance was evaluated and compared after being combined with a PET detector consisting of Lutetium Yttrium Orthosilicate crystals optically coupled with SiPM. The diode-based SCD circuit with grounding path achieved a crosstalk ratio, energy resolution, coincidence timing resolution (CTR), and mean peak to valley ratio of 0.02, 14.3%, 0.5 ns, and 27.9: 1, respectively; the diode-based SCD circuit achieved 0.03, 15.9%, 0.7 ns, and 19.4: 1, respectively; the resistor-based SCD circuit with grounding path achieved 0.04, 14.5%, 0.9 ns, and 19.4: 1, respectively; and the resistor-based SCD circuit achieved 0.05, 17.8%, 1.8 ns, and 17.7: 1, respectively. These results indicate that the proposed SCD has the potential to improve not only the crosstalk but also the energy linearity, energy resolution, and CTR characteristics in PET detectors.

18 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Kuntai ParkKuntai Park
Kuntai Park
JJJiwoong Jung
Jiwoong Jung
YCYong Choi
Yong Choi
HLHyuntae Leem
Hyuntae Leem
YKYeonkyeong Kim
Yeonkyeong Kim
The purpose of this study was to investigate the feasibility of a time-of-flight (TOF) brain positron emission tomography (PET) providing high-quality images. It consisted of 30 detector blocks arranged in a ring with a diameter of 257 mm and an axial field of view of 52.2 mm. Each detector block was composed of two detector modules and two application-specific integrated circuit (ASIC) chips. The detector module was composed of an 8 × 8 array of 3 × 3 mm2 multi-pixel photon counters and an 8 × 8 array of 3.11 × 3.11 × 15 mm3 lutetium yttrium oxyorthosilicate scintillators. The 64-channel individual readout ASIC was used to acquire the position, energy, and time information of a detected gamma ray. A coincidence timing resolution of 187 ps full width at half maximum (FWHM) was achieved using a pair of channels of two detector modules. The energy resolution and spatial resolution were 6.6 ± 0.6% FWHM (without energy nonlinearity correction) and 2.5 mm FWHM, respectively. The results of this study demonstrate that the developed TOF brain PET could provide excellent performance, allowing for a reduction in radiation dose or scanning time for brain imaging due to improved sensitivity and signal-to-noise ratio.

23 November 2023 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
YKYeonkyeong Kim
Yeonkyeong Kim
JJJiwoong Jung
Jiwoong Jung
YCYong Choi
Yong Choi
HLHyuntae Leem
Hyuntae Leem
Kuntai ParkKuntai Park
Kuntai Park
SLSangwon Lee
Sangwon Lee