Khalid Alzahrani

Dr. Khalid Alzahrani

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
EAEman M. AlHamdan
Eman M. AlHamdan
ABAmr Fahad Bashiri
Amr Fahad Bashiri
FAFaisal Alnashmi
Faisal Alnashmi
SASamar Al-Saleh
Samar Al-Saleh
KAKhalid Al-Shahrani
Khalid Al-Shahrani
TATariq Abduljabbar
Tariq Abduljabbar
The aim of the study was to assess the color matching ability and color stability of a single-shade resin-based composite (Omnichroma—OM) in comparison to a conventional dental composite. One hundred and sixty lower molar acrylic teeth in four different shades (B1, B2, A3, and C3) were prepared with class I cavities. Eighty teeth were divided into two groups based on the two resin composite materials (OM and Filtek Z-350 (FT)) for cavity restoration. Three groups were included in the color matching assessment, namely Gp 1-FT, Gp 2-OM-light cured (C), and Gp 3-OM-uncured (UC) groups. The color assessment was performed prior to cavity restoration and after cavity filling and before and after light curing to detect color matching. The 80 remaining teeth were restored with OM (n = 40) and FT (n = 40); half (n = 40) were submerged in coffee and the other half (n = 40) were submerged in cola for 2 weeks. The color stability was assessed by calculating material color (spectrophotometry) changes (∆E) before and after staining in immersion medium. The means and standard deviations of the ∆E values relating to color matching and color stability (stain resistance) among the study groups were analyzed using ANOVA and Tukey’s post hoc test. FT showed significantly better color matching (lower ΔE) in comparison to OM-UC specimens for shades B1, B2, and A3 (p < 0.01). Regarding the color stability in cola, the FT samples showed significantly lower ΔE values (indicating better color stability) compared to OM samples for all four shades (p < 0.01). The ΔE values of OM and FT samples in coffee were comparable (p > 0.01), showing comparable color stability. The color matching ability of the single-shade resin composite (OM) was influenced by the tooth color. The conventional resin composite showed better color matching than the single-shade composite (OM). The color stability of the single-shade resin composite (OM) was dependent on the staining medium. The OM composite showed more compromised color stability than the conventional resin composite in cola and comparable color stability to conventional resin composite in coffee.

12 June 2024 in International Dental Journal
Verified
Journal Article
Open access
PMPrabhadevi C. Maganur
Prabhadevi C. Maganur
SVsatish vishwanathaiah
satish vishwanathaiah
MMMohammed Mashyakhy
Mohammed Mashyakhy
Abdulaziz S. AbuMelhaAbdulaziz S. AbuMelha
Abdulaziz S. AbuMelha
ARAli Robaian
Ali Robaian
VMVarsha Manoharan
Varsha Manoharan
Dental radiography is widely used in dental practices and offers a valuable resource for the development of AI technology. Consequently, many researchers have been drawn to explore its application in different areas. The current systematic review was undertaken to critically appraise developments and performance of artificial intelligence (AI) models designed for tooth numbering and detection using dento-maxillofacial radiographic images. In order to maintain the integrity of their methodology, the authors of this systematic review followed the diagnostic test accuracy criteria outlined in PRISMA-DTA. Electronic search was done by navigating through various databases such as PubMed, Scopus, Embase, Cochrane, Web of Science, Google Scholar, and the Saudi Digital Library for the articles published from 2018 to 2023. Sixteen articles that met the inclusion exclusion criteria were subjected to risk of bias assessment using QUADAS-2 and certainty of evidence was assessed using GRADE approach.AI technology has been mainly applied for automated tooth detection and numbering, to detect teeth in CBCT images, to identify dental treatment patterns and approaches. The AI models utilised in the studies included exhibited a highest precision of 99.4% for tooth detection and 98% for tooth numbering. The use of AI as a supplementary diagnostic tool in the field of dental radiology holds great potential.

1 September 2021 in Photodiagnosis and Photodynamic Therapy
Verified
Journal Article
Closed access
AAAasem M Alhenaki
Aasem M Alhenaki
Firas Khalid AlqarawiFiras Khalid Alqarawi
Firas Khalid Alqarawi
Azeem Ul Yaqin SyedAzeem Ul Yaqin Syed
Azeem Ul Yaqin Syed
FAFaris A Alshahrani
Faris A Alshahrani
FAFaris A. Alshahrani
Faris A. Alshahrani
TATariq Abduljabbar
Tariq Abduljabbar

1 June 2021 in Photodiagnosis and Photodynamic Therapy
Verified
Journal Article
Closed access
MAmazen alkahtany
mazen alkahtany
KAKhalid Almadi
Khalid Almadi
MSMaham Sohail
Maham Sohail
KAKhalid Alzahrani
Khalid Alzahrani
FVFahim Vohra
Fahim Vohra
TATariq Abduljabbar
Tariq Abduljabbar

1 December 2021 in Photodiagnosis and Photodynamic Therapy
Verified
Journal Article
Closed access
EAEman M. AlHamdan
Eman M. AlHamdan
SASamar Al-Saleh
Samar Al-Saleh
SNSidra Sadaf Nisar
Sidra Sadaf Nisar
IAIbraheem Alshiddi
Ibraheem Alshiddi
AAAbdulaziz Alqahtani
Abdulaziz Alqahtani
TATariq Abduljabbar
Tariq Abduljabbar

1 January 2020 in Journal of International Society of Preventive and Community Dentistry
Verified
Journal Article
Open access
KAKhalid Alzahrani
Khalid Alzahrani
Background: Dental implants are considered the best treatment option for replacement of missing teeth due to high survival rates and diverse applications. However, not all dental implant therapies are successful and some fail due to various biological and or/mechanical factors. The objective of this study was to systematically review primary studies that focus on the biomechanical properties of dental implants in order to determine which biomechanical properties are most important for success of dental implant therapy. Materials and Methods: An electronic database search was performed using MEDLINE (PubMed), EMBASE, Google Scholar, and CAB Abstracts. Six principal biomechanical properties were considered to prepare the search strategy for each database using key words and Boolean operators. Human and animal studies (observational studies, trials, and in vitro studies) were included in this review. Human studies that were considered eligible needed to have subjects above 18 years who received permanent restorations after implant surgery and followed up for at least 6 months after receiving permanent restorations. Studies with subjects who had absolute contraindications at the time of dental implant surgery were excluded. Results: In total, 28 studies were included in the review after application of the eligibility criteria; 18 in vitro studies, 5 cohort clinical studies, 3 animal studies, and 2 nonrandomized trials. Six in vitro studies assessed loss of preload, five in vitro studies assessed fatigue strength, four assessed implant abutment connection design, and one assessed implant diameter. Two nonrandomized trials assessed torque and six observational studies assessed the effect of cantilevers. Gold alloy coating of abutment screws resulted in higher preload values followed by titanium alloy coating and gold coating; there was a difference in preload values between coated and uncoated screws when tightened repeatedly. Preload values decreased as a function of time with majority of preload loss occurred within 10 s of tightening. The 8-degree internal conical implant performed better than the internal hex design. Higher rate of complications (porcelain chipping, de-cementation) was observed in the cantilever groups in studies. Conclusion: Biomechanical properties of implants like preload, torque, cantilever design, implant abutment design have profound effects on the survival rates of dental implants. With limiations, this review provides some important parameters to consider for successful implant therapy.