The current review aimed to collect and critically analyze the scientific peer-reviewed literature that is available about the use of digital applications for evaluation of visual parameters in electronic devices (tablets and smartphones), confirming if there are studies calibrating and validating each of these applications. Three bibliographic search engines (using the search equation described in the paper) and the Mendeley reference manager search engine were used to complete the analysis. Only articles written in English and that are evaluating the use of tests in healthy patients to measure or characterize any visual function aspects using tablets or smartphones were included. Articles using electronic visual tests to assess the results of surgical procedures or are conducted in pathological conditions were excluded. A total of 19 articles meeting these inclusion and exclusion criteria were finally analyzed. One critical point of all these studies is that there was no mention of the characterization (spatial and/or colorimetrical) of screens and the stimuli used in most of them. Only two studies described some level of calibration of the digital device before the beginning of the study. Most revised articles described non-controlled comparatives studies (73.7%), reporting some level of scientific evidence on the validation of tools, although more consistent studies are needed.
9 November 2023 in Clinical and Experimental Optometry
New digital systems are being developed for evaluating different aspects of the visual function, such as binocularity, and it is important to know their real performance in clinical practice in order to use them appropriately. The aim was to compare binocular vision measures obtained with an online digital platform with conventional measures using prisms and printed tests. Prospective study enrolling 49 healthy patients (mean age: 35.5 ± 13.6 years). A complete visual examination was performed including measurement of near phoria (cover test), negative fusional vergence (NFV) and positive fusional vergence (PFV) ranges (prism bar), and stereopsis (24 patients Randot Stereo Test and 25 patients TNO Random Dot Test 19th edition). These same parameters were also measured with the Bynocs system (Kanohi Eye Pvt Ltd). Bland - Altman plots were used to analyse the agreement between methods. Digital measurement of near phoria was significantly lower than that obtained with the cover test, with a median difference (MD) of 4.71 (-0.07-20.07) prism dioptres (pd) (p < 0.001). No significant differences were found between Bynocs and prism bar methods in NFV break (MD 2.00, range -21-26 pd, p = 0.584) and recovery points (MD 0.00, range -16-24 pd, p = .571). Near PFV were significantly lower with Bynocs (break: MD -9.00, range -38-12 pd; recovery: MD -14.00, range -43-20 pd; p < 0.001). Bynocs stereoacuity threshold was significantly lower than that obtained with TNO (p = 0.004), but significantly higher compared to Randot (p < 0.001). Large and clinically relevant confidence intervals for the comparison between digital and conventional measures were detected in Passing-Bablok analysis. Digital measures of near phoria, NFV, PFV, and stereopsis with the Bynocs platform cannot be used interchangeably with conventional measures. The normal ranges of normality for this new tool are defined.
Our purpose is to develop and validate a new iPad-based contrast sensitivity (CS) test for measuring the contrast sensitivity function at near vision (Optopad-CSF). A total of 200 eyes of 100 healthy subjects (ages 17–63) were evaluated in a comparative study between the Optopad-CSF test (near vision) and the CSV-1000E test (distance vision). The agreement between tests was assessed with the index of contrast sensitivity (ICS) and the area under the curve (AUC). CS for all the spatial frequencies in both eyes showed a negative significant correlation with age, and corrected distance, and near visual acuities (r ≤ −0.512, p ≤ 0.013). A significantly lower CS was found with the Optopad-CSF test in the over-40-year-old subgroup for all the spatial frequencies evaluated compared to the below-40 subgroup (p ≤ 0.008). The mean AUC of the Optopad-CSF test (5.84) was twice that of the CSV-1000E test (2.76). The mean ICS of the Optopad-CSF (−0.019) and CSV-1000E (−0.075) tests showed similar values, both close to 0 (p = 0.3). There was a weak but significant correlation between the Optopad-CSF and CSV-1000E ICS tests (r = 0.246, p < 0.02). A range of normality for the values obtained with the Optopad-CSF test was calculated. The mean CS values in 16 bilateral cataract patients were out of the normal range for all the spatial frequencies evaluated (p < 0.001). Optopad-CSF is a valid portable system for measuring CS at near vision for five spatial frequencies, allowing the detection of age-related changes in CSF with age and CSF loss in cataracts, with no ceiling effect.
In recent years, there has been intense development of digital diagnostic tests for vision. All of these tests must be validated for clinical use. The current study enrolled 51 healthy individuals (age 19–72 years) in which achromatic contrast sensitivity function (CSF) in near vision was measured with the printed Vistech VCTS test (Stereo Optical Co., Inc., Chicago, IL, USA) and the Optopad-CSF (developed by our research group to be used on an iPad). Likewise, chromatic CSF was evaluated with a digital test. Statistically significant differences between tests were only found for the two higher spatial frequencies evaluated (p = 0.012 and <0.001, respectively). The mean achromatic index of contrast sensitivity (ICS) was 0.02 ± 1.07 and −0.76 ± 1.63 for the Vistech VCTS and Optopad tests, respectively (p < 0.001). The ranges of agreement between tests were 0.55, 0.76, 0.78, and 0.69 log units for the spatial frequencies of 1.5, 3, 6, and 12 cpd, respectively. The mean chromatic ICS values were −20.56 ± 0.96 and −0.16 ± 0.99 for the CSF-T and CSF-D plates, respectively (p < 0.001). Furthermore, better achromatic, red–green, and blue–yellow CSF values were found in the youngest groups. The digital test allows the fast measurement of near-achromatic and chromatic CSF using a colorimetrically calibrated iPad, but the achromatic measures cannot be used interchangeably with those obtained with a conventional printed test.
Our purpose is to evaluate the binocular contrast sensitivity function (CSF) in a presbyopic population and compare the results obtained with four different simultaneous-vision center-near multifocal contact lens (MCL) designs for distance vision under two illumination conditions. Additionally, chromatic CSF (red-green and blue-yellow) was evaluated. A randomized crossover pilot study was conducted. Four daily disposable lens designs, based on simultaneous-vision and center-near correction, were compared. The achromatic contrast sensitivity function (CSF) was measured binocularly using the CSV1000e test under two lighting conditions: room light on and off. Chromatic CSF was measured using the OptoPad-CSF test. Comparison of achromatic results with room lighting showed a statistically significant difference only for 3 cpd (p = 0.03) between the baseline visit (with spectacles) and all MCLs. Comparison of achromatic results without room lighting showed no statistically significant differences between the baseline and all MCLs for any spatial frequency (p > 0.05 in all cases). Comparison of CSF-T results showed a statistically significant difference only for 4 cpd (p = 0.002). Comparison of CSF-D results showed no statistically significant difference for all frequencies (p > 0.05 in all cases). The MCL designs analyzed provided satisfactory achromatic contrast sensitivity results for distance vision, similar to those obtained with spectacles, with no remarkable differences between designs. Chromatic contrast sensitivity for the red-green and blue-yellow mechanisms revealed some differences from the baseline that should be further investigated in future studies.
29 September 2025 in Clinical and Experimental Optometry
Understanding which ocular optical factors are clearly influencing the visual performance achieved with MFCLs is essential for conducting a more optimised procedure when fitting this type of lenses. To assess and compare the induction of ocular higher-order aberrations by four daily multifocal contact lenses and evaluate the influence of pupil diameter on their performance. A randomised, crossover study evaluated four contact lenses in 20 presbyopic participants. Subjective refraction, distance/intermediate/near visual acuity and patient-reported visual satisfaction, and pupil diameter under four lighting conditions were assessed. Pupillary dynamic were calculated as the difference between mesopic and photopic pupil sizes. Primary coma, trefoil, spherical aberration, and higher-order aberration (HOA) root mean square were analysed. A significant negative induction of primary spherical aberration was found with all lenses (p ≤ 0.04); being greater with MyDay than Moist in both eyes and with Total1 than Moist in non-dominant eyes (p ≤ 0.02). Coma and HOA increased significantly with all lenses (p ≤ 0.03), except for the Moist lens in dominant eyes; being greater with Total1 than Moist in dominant eyes (p ≤ 0.049). Odd aberrations showed inverse correlations with intermediate/near visual acuity and patient satisfaction (rho≤-0.58, p ≤ 0.04). Greater pupillary dynamic variation was significantly associated with better intermediate/near visual acuity for MyDay and Biotrue MCLs in dominant eyes (rho≤-0.59, p ≤ 0.04). Centre-near multifocal contact lenses induce negative primary spherical aberration. Interestingly, greater coma aberration correlates with improved visual acuity and patient satisfaction at intermediate and near distances. Additionally, larger pupillary dynamic variation may enhance visual acuity and satisfaction in certain presbyopic contact lens wearers.