The variation in transmittance produced when a photopolymer is irradiated with a pulsed laser is analyzed and experimental results obtained when diffraction gratings are stored using pulsed exposure are presented. In either case, the influence of the energy of the irradiation pulse, the number of pulses, and the pulse repetition rate were studied. The photopolymer used was an acrylamide/polyvinyl alcohol dry film with a yellow eosin-thiethanol-amine mixture as a photoinitiator system. The recording of the gratings was performed by use of a holographic copying process. The samples were exposed and holograms recorded with a collimated beam from a frequency-doubled Nd:YAG (532 nm) Q-switched laser. Our initial results show that it is possible to obtain diffraction gratings with a diffraction efficiency of 60% and a refractive index modulation up to 2.8 × 10-3. The energetic sensitivities achieved are close to those obtained with the same material and continuous irradiation without a preprocessing of the gratings.
In recent years, holographic optical elements have been introduced in different applications such as high-density data storage, interconnections, spatial and temporal filters and three-dimensional displays. Simultaneously, more sensitive, efficient and durable holographic materials have been developed. Thus it is necessary to analyze the characteristics of these elements in the holographic materials developed. In this paper a method to obtain holographic lenses in a photopolymer is presented. In order to obtain, reconstruct and analyze these lenses, an optical device was designed. Once the holographic lenses are obtained, the device allows us to capture the images provided by these lenses. The imaging quality of these lenses was evaluated by means of the modulation transfer function (MTF) and the contrast. Lenses of different focal lengths were recorded. The holographic lenses obtained had high diffraction efficiency and temporal stability. Moreover, the resolution was greater than that of other lenses with the same diaphragm number.
Our purpose is to develop and validate a new iPad-based contrast sensitivity (CS) test for measuring the contrast sensitivity function at near vision (Optopad-CSF). A total of 200 eyes of 100 healthy subjects (ages 17–63) were evaluated in a comparative study between the Optopad-CSF test (near vision) and the CSV-1000E test (distance vision). The agreement between tests was assessed with the index of contrast sensitivity (ICS) and the area under the curve (AUC). CS for all the spatial frequencies in both eyes showed a negative significant correlation with age, and corrected distance, and near visual acuities (r ≤ −0.512, p ≤ 0.013). A significantly lower CS was found with the Optopad-CSF test in the over-40-year-old subgroup for all the spatial frequencies evaluated compared to the below-40 subgroup (p ≤ 0.008). The mean AUC of the Optopad-CSF test (5.84) was twice that of the CSV-1000E test (2.76). The mean ICS of the Optopad-CSF (−0.019) and CSV-1000E (−0.075) tests showed similar values, both close to 0 (p = 0.3). There was a weak but significant correlation between the Optopad-CSF and CSV-1000E ICS tests (r = 0.246, p < 0.02). A range of normality for the values obtained with the Optopad-CSF test was calculated. The mean CS values in 16 bilateral cataract patients were out of the normal range for all the spatial frequencies evaluated (p < 0.001). Optopad-CSF is a valid portable system for measuring CS at near vision for five spatial frequencies, allowing the detection of age-related changes in CSF with age and CSF loss in cataracts, with no ceiling effect.
In this work we try to understand the real effect of increase in aberrations after Femto-LASIK surgery on the patient’s final visual quality, specifically when the visual acuity measurement is considered. A clinical study with 37 eyes of 20 patients that underwent myopic Femto-LASIK surgery and different personalized eye model simulations were carried out. In clinical study, correlations between pre- and postoperative parameters with visual acuity were analysed. Eye simulations (based on real data) provided simulations of vision quality before and after surgery. Our main results showed a significant increase in aberrations was obtained after surgery; however, no differences were found between the preoperative corrected distance visual acuity (CDVA) and the postoperative uncorrected distance visual acuity (UDVA). This absence of differences in visual quality could be explained by performing different simulations on three eyes that would cover most of the possible clinical situations. Simulations were implemented considering a pupil size of 2.5 mm and the personalized data of each patient. Results showed that final visual acuity (VA) change are determined by the final high-order aberrations (HOAS) and their increase after surgery but measured under photopic conditions. In conclusion, customized analysis of higher-order aberrations in scotopic pupils better predicts patient visual acuity after Lasik surgery.
Background/Objectives: To assess the optical performance of two refractive premium IOLs across pupil sizes and values of corneal spherical aberration (SA). Methods: Two refractive IOLs were evaluated in this study: Tecnis Eyhance and Mini Well. The surface profiles were obtained to calculate the through-object MTF (TO MTF) curves and simulate optotype images. Entrance pupil sizes ranging from 2 to 5.5 and three corneal models were analyzed in the simulation: an average population aberrated cornea, an aberration-free cornea and a post-Lasik myopic cornea. Results: For Model 1 and pupil sizes between 3.0 and 3.5 mm, Mini Well provided acceptable visual quality from far to near distances, whereas Eyhance struggled to maintain visual quality at distances closer than intermediate. For patients with lower-than-normal corneal SA (i.e., more prolate corneas, such as post-hyperopic LASIK) both IOLs exhibited a hyperopic shift in far focus. Conversely, for patients with higher-than-normal corneal SA (i.e., more oblate corneas, such as post-myopic LASIK), the shift occurred in the myopic direction. Despite the implementation of an optimized IOL power to circumvent any shift, the TO MTF nevertheless reflected the interaction between corneal and IOL SA. Furthermore, the Mini Well demonstrated increased tolerance to less negative SA values, while Eyhance exhibited behavior consistent with a monofocal lens for more positive SA values. Conclusions: Surgeons should consider each patient’s corneal asphericity and typical pupil diameter when selecting and calculating the power of the premium IOLs studied, particularly in patients with a history of refractive surgery.
Background/Objectives: Premium intraocular lenses (IOLs) are increasingly being selected for cataract and refractive lens surgery, but their functional performance depends critically on pupil size and corneal spherical aberration (SA). This study evaluates how these factors modulate the optical behavior of the RayOne EMV and Tecnis Synergy using a profilometry-based Through Object modulation transfer function (TO MTF) analysis. Methods: The surface profiles of the RayOne EMV and Tecnis Synergy were measured with a confocal optical profilometer and implemented in pseudophakic eye models via ray tracing. TO MTF at 50 cycles/mm was computed for object vergences from −4.0 D to +2.0 D over entrance pupil diameters from 2.0 to 5.5 mm in three corneal configurations derived from the Liou–Brennan model and ISO recommendations: mean population SA, aberration-free, and a myopic LASIK-like oblate cornea. Simulated optotype images were generated to relate TO MTF values to the expected distant, intermediate, and near visual performances. Results: RayOne EMV delivered high-quality distant image performance in all models. Its depth of focus increased only modestly and showed a strong dependence on pupil size. Intermediate and near vision rarely reached clinically acceptable levels. The Tecnis Synergy produced a broad depth-of-field plateau in distant to near visual performance for mean population spherical aberration at a 3.5 mm pupil. However, image quality at 90 cm remained limited. Optical performance worsened with increasing pupil size and positive spherical aberration, particularly under post-myopic LASIK conditions. Conclusions: The RayOne EMV behaves predominantly as a distance-oriented design with minimal true presbyopic benefit; the Tecnis Synergy provides a wider range of vision but is highly sensitive to corneal spherical aberration and pupil size, so thorough preoperative evaluation of corneal asphericity and functional pupil diameter is essential for IOL selection and power targeting.