Anca Jivănescu

Prof. Dr. Anca Jivănescu

Victor Babeș University of Medicine and Pharmacy Timișoara, Timişoara, Timiş, Romania
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Codruta Eliza IlleCodruta Eliza Ille
Codruta Eliza Ille
AJAnca Jivănescu
Anca Jivănescu
DPDaniel Alexandru Pop
Daniel Alexandru Pop
ESEniko Tunde Stoica
Eniko Tunde Stoica
RFRăzvan Fluieraș
Răzvan Fluieraș
IOIustin Olariu
Iustin Olariu
The present review provides an up-to-date overview of chairside CAD/CAM materials used in restorative dentistry, focusing on their classification, properties, and clinical applications. If CAD/CAM technology was only an aspiration in the past, a higher proportion of clinics are employing it nowadays. The market is overflowing with biomaterials, and these materials are constantly evolving, making it challenging for practitioners to choose the most appropriate one, especially in correlation with patients’ medical diseases. The evolution of CAD/CAM technology has revolutionized dental practice, enabling the efficient fabrication of high-quality restorations in a single appointment. The main categories of chairside CAD/CAM materials include feldspathic ceramics, leucite-reinforced ceramics, lithium disilicate, zirconia, hybrid ceramics, and acrylic resins. The mechanical, physical, and aesthetic properties of these materials are discussed, along with their advantages and limitations for different clinical scenarios. Factors influencing material selection, such as strength, aesthetics, and ease of use, are also assessed. Ultimately, the guiding principle of dentistry is minimally invasive treatment following the particularity of the clinical case to obtain the envisioned result. Correlating all these factors, a simple, up-to-date classification is required to begin an individualized treatment. By synthesizing current evidence, this comprehensive review aims to guide clinicians in selecting appropriate chairside CAD/CAM materials to achieve optimal functional and aesthetic outcomes in restorative procedures. The integration of digital workflows and continued development of novel materials promise to further enhance the capabilities of chairside CAD/CAM systems in modern dental practice.

15 September 2015 in Current Diabetes Reports
Verified
Journal Article
Closed access
PDF file
WBWenche S. Borgnakke
Wenche S. Borgnakke
PAPatricia F. Anderson
Patricia F. Anderson
CSCarol Shannon
Carol Shannon
AJAnca Jivănescu
Anca Jivănescu

22 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
RRRaul Rotar
Raul Rotar
AFAndrei Bogdan Faur
Andrei Bogdan Faur
DPDaniel Pop
Daniel Pop
AJAnca Jivănescu
Anca Jivănescu
Intraoral scanners (IOS) have reached a point where their impact in the dental office cannot be denied. The distance between the tip of the IOS and the preparation may have implications on the accuracy of the digital model. The objective of this study was to evaluate the differences in accuracy between digital impressions in the scenario of different scanning distances. Twenty consecutive scans were performed at five predetermined distances: 5 mm, 10 mm, 15 mm, 20 mm and 23 mm by a single operator. The scanning distance of 10 mm displayed the best accuracy with an overall trueness value of 23.05 μm and precision value of 4.2 μm. The drawn conclusion was that increased scanning distances can decrease the accuracy of a digital impression.

25 June 2021 in Materials
Verified
Journal Article
Open access
PDF file
DPDaniel Alexandru Pop
Daniel Alexandru Pop
RBRoxana Buzatu
Roxana Buzatu
Elena Alina MoacaElena Alina Moaca
Elena Alina Moaca
Claudia G WatzClaudia G Watz
Claudia G Watz
Simona Cinta PinzaruSimona Cinta Pinzaru
Simona Cinta Pinzaru
AJAnca Jivănescu
Anca Jivănescu
The current study presents the effect of naked Fe3O4@Carbon nanoparticles obtained by the combustion method on primary human gingival fibroblasts (HGFs) and primary gingival keratinocytes (PGKs)—relevant cell lines of buccal oral mucosa. In this regard, the objectives of this study were as follows: (i) development via combustion method and characterization of nanosized magnetite particles with carbon on their surface, (ii) biocompatibility assessment of the obtained magnetic nanoparticles on HGF and PGK cell lines and (iii) evaluation of possible irritative reaction of Fe3O4@Carbon nanoparticles on the highly vascularized chorioallantoic membrane of a chick embryo. Physicochemical properties of Fe3O4@Carbon nanoparticles were characterized in terms of phase composition, chemical structure, and polymorphic and molecular interactions of the chemical bonds within the nanomaterial, magnetic measurements, ultrastructure, morphology, and elemental composition. The X-ray diffraction analysis revealed the formation of magnetite as phase pure without any other secondary phases, and Raman spectroscopy exhibit that the pre-formed magnetic nanoparticles were covered with carbon film, resulting from the synthesis method employed. Scanning electron microscopy shown that nanoparticles obtained were uniformly distributed, with a nearly spherical shape with sizes at the nanometric level; iron, oxygen, and carbon were the only elements detected. While biological screening of Fe3O4@Carbon nanoparticles revealed no significant cytotoxic potential on the HGF and PGK cell lines, a slight sign of irritation was observed on a limited area on the chorioallantoic membrane of the chick embryo.

11 October 2022 in Materials
Verified
Journal Article
Open access
PDF file
LALiane Tabitha Avram
Liane Tabitha Avram
SGSergiu-Valentin Galatanu
Sergiu-Valentin Galatanu
COCarmen Opriș
Carmen Opriș
CPCristian Pop
Cristian Pop
AJAnca Jivănescu
Anca Jivănescu
The objective of this study was to evaluate the influence of hydrofluoric acid (HF) and conditioning time on the micro-shear bond strength (µSBS) between dual-cure resin cement and glass-ceramic materials, such as lithium disilicate ceramic (IPS e.max CAD, Ivoclar Vivadent) (EX) and leucite-reinforced ceramic (IPS Empress CAD, Ivoclar Vivadent) (EP), and also a hybrid ceramic (Vita Enamic, Vita Zahnfabrik) (VE). Eighteen sections with 1 mm thickness were cut from each CAD/CAM material and randomly divided into three groups, according to the surface etching time (30 s, 60 s, 90 s). The surface treatment was performed using 9.5% HF acid gel, then resin cement was applied on the prepared ceramic plates and light cured. µSBS values between resin cement and the ceramic material were measured with a universal testing machine at a crosshead speed of 0.5 mm/min until the failure occurred. The fractured surfaces of specimens were microscopically evaluated, and failure modes were classified as: adhesive between resin cement and ceramic, cohesive within ceramic or cement and mixed failure. Surface roughness of etched samples was examined using a scanning electron microscope. Obtained data were statistically analysed using one-way analysis of variance (ANOVA) and Bonferroni post hoc test with a level of significance α = 0.05. The results of the statistical methods applied indicate that µSBS mean difference for leucite-reinforced ceramic (EP) was statistically significant (p < 0.05). However, µSBS values for hybrid ceramic (VE) and lithium disilicate ceramic (EX) were not affected, from a statistical point of view, by the conditioning time (p > 0.05).

27 May 2021 in Scanning
Verified
Journal Article
Open access
PDF file
AJAnca Jivănescu
Anca Jivănescu
AFAndrei Bogdan Faur
Andrei Bogdan Faur
RRRaul Rotar
Raul Rotar
The aim of this study was to evaluate the influence of different settings of ambient light intensity inside the dental office on the accuracy (trueness and precision) of an intraoral scanner (IOS). A full crown preparation was conducted on a resin molar which was scanned using a high resolution extraoral scanner to obtain a reference model. Six light settings were chosen based on the most clinically relevant light conditions inside the workspace, and the preparation was scanned using an intraoral scanner (PlanScan, Planmeca). The obtained data was analyzed using a professional 3D quality control software (Geomagic Control X). There was no statistically relevant difference between the groups when regarding trueness, although a slight influence of the light intensity could be observed on the trueness values. Regarding precision, the best results were obtained in the 3800 lux group, with the other groups presenting close values, excepting the extreme values (400 lux and 11 000 lux) groups that proved to be the most deficient.