Eoghan Vaughan

Mr. Eoghan Vaughan

Tyndall National Institute, Cork, Ireland
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2022 in Talanta
Verified
Journal Article
Closed access
JMJulia Madden
Julia Madden
EVEoghan Vaughan
Eoghan Vaughan
MTMichael Thompson
Michael Thompson
ARAlan O’ Riordan
Alan O’ Riordan
PGPaul Galvin
Paul Galvin
STSofia Rodrigues Teixeira
Sofia Rodrigues Teixeira

4 August 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
GPGeorge Paterakis
George Paterakis
EVEoghan Vaughan
Eoghan Vaughan
DGDinesh R. Gawade
Dinesh R. Gawade
RMRichard Murray
Richard Murray
GGGeorge Gorgolis
George Gorgolis
CGCostas Galiotis
Costas Galiotis
Ultra-sensitive and responsive humidity sensors were fabricated by deposition of graphene oxide (GO) on laser-induced graphene (LIG) electrodes fabricated by a low-cost visible laser scribing tool. The effects of GO layer thickness and electrode geometry were investigated. Sensors comprising 0.33 mg/mL GO drop-deposited on spiral LIG electrodes exhibited high sensitivity up to 1800 pF/% RH at 22 °C, which is higher than previously reported LIG/GO sensors. The high performance was ascribed to the high density of the hydroxyl groups of GO, promoted by post-synthesis sonication treatment, resulting in high water physisorption rates. As a result, the sensors also displayed good stability and short response/recovery times across a wide tested range of 0–97% RH. The fabricated sensors were benchmarked against commercial humidity sensors and displayed comparable performance and stability. Finally, the sensors were integrated with a near-field communication tag to function as a wireless, battery-less humidity sensor platform for easy read-out of environmental humidity values using smartphones.

13 July 2023 in Advanced Sensor Research
Verified
Journal Article
Open access
EVEoghan Vaughan
Eoghan Vaughan
CSChiara Santillo
Chiara Santillo
MSMichele Setti
Michele Setti
CLCathal Larrigy
Cathal Larrigy
AQAidan J. Quinn
Aidan J. Quinn
Daniela IacopinoDaniela Iacopino
Daniela Iacopino
Cork laser induced graphene (cork‐LIG) electrochemical sensors are fabricated by direct laser writing of natural cork sheets. Laser writing is performed with a hobbyist visible laser. The obtained cork‐LIG structures display graphene‐like Raman signatures, high conductivity, and fast electron‐transfer rates. After a 10 min electrochemical pretreatment, electrodes are used for detection of Tyrosine (Tyr) in the presence of uric acid, dopamine, ascorbic acid, urea, and glucose. linear detection of tyrosine is achieved in the 5–150 µm range with a limit of detection (LOD) of 3.03 µm. Calibration of dopamine detection is achieved with a LOD of 1.1 µm. Finally, the cork‐LIG electrochemical sensors show linear response of Tyr in artificial sweat in the relevant physiological range of 5–250 μm (sensitivity, 1.8×10−2 A m−1). The LOD is calculated as 3.75 μm. These results open the door to the exploitation of renewable materials such as cork for the development of high‐quality, green sensors for the monitoring of health and wellbeing parameters.

19 August 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
PTPei Shee Tan
Pei Shee Tan
EVEoghan Vaughan
Eoghan Vaughan
JIJahidul Islam
Jahidul Islam
NBNiall Burke
Niall Burke
Daniela IacopinoDaniela Iacopino
Daniela Iacopino
JTJoanna Tierney
Joanna Tierney
Interleukin-6 (IL-6) is an important immuno-modulating cytokine playing a pivotal role in inflammatory processes in disease induction and progression. As IL-6 serves as an important indicator of disease state, it is of paramount importance to develop low cost, fast and sensitive improved methods of detection. Here we present an electrochemical immunosensor platform based on the use of highly porous graphitic carbon electrodes fabricated by direct laser writing of commercial polyimide tapes and chemically modified with capture IL-6 antibodies. The unique porous and 3D morphology, as well as the high density of edge planes of the graphitic carbon electrodes, resulted in a fast heterogeneous electron transfer (HET) rate, k0 = 0.13 cm/s. The resulting immunosensor showed a linear response to log of concentration in the working range of 10 to 500 pg/mL, and low limit of detection (LOD) of 5.1 pg/mL IL-6 in phosphate buffer saline. The total test time was approximately 90 min, faster than the time required for ELISA testing. Moreover, the assay did not require additional sample pre-concentration or labelling steps. The immunosensor shelf-life was long, with stable results obtained after 6 weeks of storage at 4 °C, and the selectivity was high, as no response was obtained in the presence of another inflammatory cytokine, Interlukin-4. These results show that laser-fabricated graphitic carbon electrodes can be used as selective and sensitive electrochemical immunosensors and offer a viable option for rapid and low-cost biomarker detection for point-of-care analysis.

1 September 2023 in ACS Sustainable Chemistry & Engineering
Verified
Journal Article
Open access
EVEoghan Vaughan
Eoghan Vaughan
CSChiara Santillo
Chiara Santillo
AIAlessandra Imbrogno
Alessandra Imbrogno
Gennaro GentileGennaro Gentile
Gennaro Gentile
AQAidan J. Quinn
Aidan J. Quinn
Daniela IacopinoDaniela Iacopino
Daniela Iacopino
In this study, the laser-induced graphitization process of sustainable chitosan-based formulations was investigated. In particular, optimal lasing conditions were investigated alongside the effect of borax concentration in the chitosan matrix. In all cases, it was found that the obtained formulations were graphitizable with a CO2 laser. This process gave rise to the formation of high surface area, porous, and electrically conductive laser-induced graphene (LIG) structures. It was found that borax, as a cross-linker of chitosan, enabled the graphitization process when its content was ≥30 wt % in the chitosan matrix, allowing the formation of an LIG phase with a significant content of graphite-like structures. The graphitization process was investigated by thermogravimetric analysis (TGA), Raman, X-ray photoemission (XPS), and Fourier transform infrared (FTIR) spectroscopies. LIG electrodes obtained from CS/40B formulations displayed a sheet resistance as low as 110 Ω/sq. Electrochemical characterization was performed after a 10 min electrode activation by cycling in 1 M KCl. A heterogeneous electron transfer rate, k0, of 4 × 10-3 cm s-1 was determined, indicating rapid electron transfer rates at the electrode surface. These results show promise for the introduction of a new class of sustainable composites for LIG electrochemical sensing platforms.

14 July 2022 in Nanotechnology
Verified
Journal Article
Open access
RMRichard Murray
Richard Murray
OOOrla O’nEill
Orla O’nEill
EVEoghan Vaughan
Eoghan Vaughan
Daniela IacopinoDaniela Iacopino
Daniela Iacopino
ABAlan Blake
Alan Blake
AQAidan J Quinn
Aidan J Quinn
We report a simple, scalable two-step method for direct-write laser fabrication of 3D, porous graphene-like carbon electrodes from polyimide films with integrated contact plugs to underlying metal layers (Au or Ni). Irradiation at high average CO2 laser power (30 W) and low scan speed (∼18 mm s)−1 leads to formation of ‘keyhole’ contact plugs through local ablation of polyimide (initial thickness 17 μm) and graphitization of the plug perimeter wall. Top-surface laser-induced graphene (LIG) electrodes are then formed and connected to the plug by raster patterning at lower laser power (3.7 W) and higher scan speed (200 mm s)−1. Sheet resistance data (71 ± 15 Ω sq.)−1 indicates formation of high-quality surface LIG, consistent with Raman data which yield sharp first- and second-order peaks. We have also demonstrated that high-quality LIG requires a minimum initial polyimide thickness. Capacitance data measured between surface LIG electrodes and the buried metal film indicate a polyimide layer of thickness ∼7 μm remaining following laser processing. By contrast, laser graphitization of polyimide of initial thickness ∼8 μm yielded devices with large sheet resistance (>1 kΩ sq.)−1. Raman data also indicated significant disorder. Plug contact resistance values were calculated from analysis of transfer line measurement data for single- and multi-plug test structures. Contacts to buried nickel layers yielded lower plug resistances (1-plug: 158 ± 7 Ω , 4-plug: 31 ± 14 Ω) compared to contacts to buried gold (1-plug: 346 ± 37 Ω , 4-plug: 52 ± 3 Ω). Further reductions are expected for multi-plug structures with increased areal density. Proof-of-concept mm-scale LIG electrochemical devices with local contact plugs yielded rapid electron transfer kinetics (rate constant k 0 ∼ 0.017 cm s−1), comparable to values measured for exposed Au films (k 0 ∼0.023 cm s)−1. Our results highlight the potential for integration of LIG-based sensor electrodes with semiconductor or roll-to-roll manufacturing.