Wei-Chen Lin

Mr. Wei-Chen Lin

National Changhua University of Education

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
YLYih Der Lee
Yih Der Lee
WLWei-Chen Lin
Wei-Chen Lin
JJJheng-Lun Jiang
Jheng-Lun Jiang
JCJia-Hao Cai
Jia-Hao Cai
Wei-Tzer HuangWei-Tzer Huang
Wei-Tzer Huang
KYKai-chao Yao
Kai-chao Yao
This study aimed to propose individual phase voltage regulation strategies using the sparrow search algorithm (SSA) in the IEEE 8500-node large-scale unbalanced distribution network with high photovoltaic (PV) penetration. The proposed approach is capable of individual phase regulation, which coordinates the on-load tap changer (OLTC), voltage regulator (VR), switched capacitor bank (SCB), and volt–var setting controlled by a smart inverter to improve voltage variation and unbalance. Consequently, the change time of VRs, the switched times of SCBs, and the individual phase voltage magnitude and unbalance ratio are considered in the fitness function for the SSA. The simulation scenarios fully consider the unbalanced load conditions and PV power output patterns, and the numerical results demonstrate that the voltage variation and unbalance are clearly improved, by 15% and 26%, respectively. The fitness values, operation times of OLTC, VR, and SCB, and the settings of the volt–var controlled smart inverter are also optimized by the SSA. The outcomes of this study are helpful for distribution system operators in formulating voltage control strategies corresponding to different system conditions.

30 July 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WLWei-Chen Lin
Wei-Chen Lin
Wei-Tzer HuangWei-Tzer Huang
Wei-Tzer Huang
KYKai-chao Yao
Kai-chao Yao
HCHong-Ting Chen
Hong-Ting Chen
CMChun-Chiang Ma
Chun-Chiang Ma
This aim of this work was to develop an integrated fault location and restoration approach for microgrids (MGs). The work contains two parts. Part I presents the fault location algorithm, and Part II shows the restoration algorithm. The proposed algorithms are implemented by particle swarm optimization (PSO). The fault location algorithm is based on network connection matrices, which are the modifications of bus-injection to branch-current and branch-current to bus-voltage (BCBV) matrices, to form the new system topology. The backward/forward sweep approach is used for the prefault power flow analysis. After the occurrence of a fault, the voltage variation at each bus is calculated by using the Zbus modification algorithm to modify Zbus. Subsequently, the voltage error matrix is computed to search for the fault section by using PSO. After the allocation of the fault section, the multi-objective function is implemented by PSO for optimal restoration with its constraints. Finally, the IEEE 37-bus test system connected to distributed generations was utilized as the sample system for a series simulation and analysis. The outcomes demonstrated that the proposed optimal algorithm can effectively solve fault location and restoration problems in MGs.

10 April 2020 in Energies
Verified
Journal Article
Open access
PDF file
YLYih Der Lee
Yih Der Lee
JJJheng-Lun Jiang
Jheng-Lun Jiang
YHYuan-Hsiang Ho
Yuan-Hsiang Ho
WLWei-Chen Lin
Wei-Chen Lin
HCHsin-Ching Chih
Hsin-Ching Chih
Wei-Tzer HuangWei-Tzer Huang
Wei-Tzer Huang
An increase in the neutral current results in a malfunction of the low energy over current (LCO) protective relay and raises the neutral-to-ground voltage in three-phase, four-wire radial distribution feeders. Thus, the key point for mitigating its effect is to keep the current under a specific level. The most common approach for reducing the neutral current caused by the inherent imbalance of distribution feeders is to rearrange the phase connection between the distribution transformers and the load tapped-off points by using the metaheuristics algorithms. However, the primary task is to obtain the effective load data for phase rearrangement; otherwise, the outcomes would not be worthy of practical application. In this paper, the effective load data can be received from the feeder terminal unit (FTU) installed along the feeder of Taipower. The net load data consisting of customers’ power consumption and the power generation of distributed energy resources (DERs) were measured and transmitted to the feeder dispatch control center (FDCC). This paper proposes a method of establishing the equivalent full-scale net load model based on FTU data format, and the long short-term memory (LSTM) was adopted for monthly load forecasting. Furthermore, the full-scale net load model was built by the monthly per hour load data. Next, the particle swarm optimization (PSO) algorithm was applied to rearrange the phase connection of the distribution transformers with the aim of minimizing the neutral current. The outcomes of this paper are helpful for the optimal setting of the limit current of the LCO relay and to avoid its malfunction. Furthermore, the proposed method can also improve the three-phase imbalance of distribution feeders, thus reducing extra power loss and increasing the operating efficiency of three-phase induction motors.