Jheng-Lun Jiang

Dr. Jheng-Lun Jiang


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2020 in Energies
Verified
Journal Article
Open access
PDF file
YLYu-Jen Liu
Yu-Jen Liu
YTYu-Hsuan Tai
Yu-Hsuan Tai
YLYih Der Lee
Yih Der Lee
JJJheng-Lun Jiang
Jheng-Lun Jiang
CLChen-Wei Lin
Chen-Wei Lin
PV hosting capacity (PVHC) analysis on a distribution system is an attractive technique that emerged in recent years for dealing with the planning tasks on high-penetration PV integration. PVHC uses various system performance indices as judgements to find an available amount of PV installation capacity that can be accommodated on existing distribution system infrastructure without causing any violation. Generally, approaches for PVHC assessments are implemented by iterative power flow calculations with stochastic PV deployments so as to observe the operation impacts for PV installation on distribution systems. Determination of the stochastic PV deployments in most of traditional PVHC analysis methods is automatically carried out by the program that is using random selection. However, a repetitive problem that exists in these traditional methods on the selection of the same PV deployment for a calculation was not previously investigated or discussed; further, underestimation of PVHC results may occur. To assess PVHC more effectively, this paper proposes an improved stochastic analysis method that introduces an innovative idea of using repetitiveness check mechanism to overcome the shortcomings of the traditional methods. The proposed mechanism firstly obtains all PV deployment combinations for the determination of all possible PV installation locations. A quick-sorting algorithm is then used to remove repetitive PV deployments that are randomly selected during the solution procedure. Finally, MATLAB and OpenDSS co-simulations implemented on a small distribution feeder are used to validate the performance of the proposed method; in addition, PVHC enhancement by PV inverter control is investigated and simulated in this paper as well. Results show that the proposed method is more effective than traditional methods in PVHC assessments.

12 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
YLYih Der Lee
Yih Der Lee
WLWei-Chen Lin
Wei-Chen Lin
JJJheng-Lun Jiang
Jheng-Lun Jiang
JCJia-Hao Cai
Jia-Hao Cai
Wei-Tzer HuangWei-Tzer Huang
Wei-Tzer Huang
KYKai-chao Yao
Kai-chao Yao
This study aimed to propose individual phase voltage regulation strategies using the sparrow search algorithm (SSA) in the IEEE 8500-node large-scale unbalanced distribution network with high photovoltaic (PV) penetration. The proposed approach is capable of individual phase regulation, which coordinates the on-load tap changer (OLTC), voltage regulator (VR), switched capacitor bank (SCB), and volt–var setting controlled by a smart inverter to improve voltage variation and unbalance. Consequently, the change time of VRs, the switched times of SCBs, and the individual phase voltage magnitude and unbalance ratio are considered in the fitness function for the SSA. The simulation scenarios fully consider the unbalanced load conditions and PV power output patterns, and the numerical results demonstrate that the voltage variation and unbalance are clearly improved, by 15% and 26%, respectively. The fitness values, operation times of OLTC, VR, and SCB, and the settings of the volt–var controlled smart inverter are also optimized by the SSA. The outcomes of this study are helpful for distribution system operators in formulating voltage control strategies corresponding to different system conditions.

10 April 2020 in Energies
Verified
Journal Article
Open access
PDF file
YLYih Der Lee
Yih Der Lee
JJJheng-Lun Jiang
Jheng-Lun Jiang
YHYuan-Hsiang Ho
Yuan-Hsiang Ho
WLWei-Chen Lin
Wei-Chen Lin
HCHsin-Ching Chih
Hsin-Ching Chih
Wei-Tzer HuangWei-Tzer Huang
Wei-Tzer Huang
An increase in the neutral current results in a malfunction of the low energy over current (LCO) protective relay and raises the neutral-to-ground voltage in three-phase, four-wire radial distribution feeders. Thus, the key point for mitigating its effect is to keep the current under a specific level. The most common approach for reducing the neutral current caused by the inherent imbalance of distribution feeders is to rearrange the phase connection between the distribution transformers and the load tapped-off points by using the metaheuristics algorithms. However, the primary task is to obtain the effective load data for phase rearrangement; otherwise, the outcomes would not be worthy of practical application. In this paper, the effective load data can be received from the feeder terminal unit (FTU) installed along the feeder of Taipower. The net load data consisting of customers’ power consumption and the power generation of distributed energy resources (DERs) were measured and transmitted to the feeder dispatch control center (FDCC). This paper proposes a method of establishing the equivalent full-scale net load model based on FTU data format, and the long short-term memory (LSTM) was adopted for monthly load forecasting. Furthermore, the full-scale net load model was built by the monthly per hour load data. Next, the particle swarm optimization (PSO) algorithm was applied to rearrange the phase connection of the distribution transformers with the aim of minimizing the neutral current. The outcomes of this paper are helpful for the optimal setting of the limit current of the LCO relay and to avoid its malfunction. Furthermore, the proposed method can also improve the three-phase imbalance of distribution feeders, thus reducing extra power loss and increasing the operating efficiency of three-phase induction motors.

27 July 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
Te-Tien KuTe-Tien Ku
Te-Tien Ku
CLChia-Hung Lin
Chia-Hung Lin
CCChao-Shun Chen
Chao-Shun Chen
YLYih Der Lee
Yih Der Lee
JJJheng-Lun Jiang
Jheng-Lun Jiang
CCChen-Min Chan
Chen-Min Chan
With the growing penetration of distributed energy resources (DER), the accompanying challenges have led utilities to limit the hosting capacities of DER installations on distribution feeders. A distribution static synchronous compensator (DSTATCOM) is a power electronic device to provide dynamic injections and absorption of reactive power into the distribution grid with more flexible and reliable voltage control and power quality improvement. A distributed energy resources management system (DERMS) is developed to provide more effective control of a DSTATCOM that can help substantially increase hosting capacity and mitigate overvoltage problems with the existing feeder. A Taiwan power company’s (Taipower) feeder is selected for computer simulation, and the DSTATCOM is employed in the test feeder to demonstrate the effectiveness of the DSTATCOM in improving the overvoltage problems. The voltage/reactive power (Volt/VAR) control of the DSTATCOM helps reduce overvoltage/voltage fluctuations as the DER output increases.

12 September 2020 in Preprints.org
Verified
Preprint
Open access
PDF file
JJJheng-Lun Jiang
Jheng-Lun Jiang
SWShen Szu Wang
Shen Szu Wang
YLYih Der Lee
Yih Der Lee
YCYung-Ruei Chang
Yung-Ruei Chang
When a microgrid is grid-tied to a distribution system, it can provide surplus power generation to the distribution system, if any abnormality or interruption occurs in the distribution system, the microgrid can operate in standalone mode to isolate the impact of the abnormality or interruption. However, if the microgrid can not collect enough information from the distribution system, it may cause the failure of generation transferring of distribution feeders, or even further influence the stability of the distribution system. In this paper, a strategy for the resilient control of a microgrid is proposed. It can solve the above-mentioned problem, reduce the duration of the outage of loads. This strategy is experimented in the microgrid in the Institute of Nuclear Energy Research (INER), the reliability is also analyzed to evaluate the unavailability of the microgrid in INER, and it is verified that the proposed strategy can reduce the duration of the outage of loads, and hence the reliability of a microgrid can be upgraded.

1 January 2016 in International Journal of Computer and Electrical Engineering
Verified
Journal Article
Closed access
KLKeng-Yu Lien
Keng-Yu Lien
DBDuong Minh Bui
Duong Minh Bui
YCYung-Ruei Chang
Yung-Ruei Chang
YLYih Der Lee
Yih Der Lee
JJJheng-Lun Jiang
Jheng-Lun Jiang
CLChing-Chih Lin
Ching-Chih Lin