Emmanuel Brun

Dr. Emmanuel Brun

1. Inserm UA7 Strobe, French Institute of Health and Medical Research, 75654 Paris, France
+1
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2014 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Verified
Journal Article
Closed access
AMAlessandro Mirone
Alessandro Mirone
EBEmmanuel Brun
Emmanuel Brun
EGEmmanuelle Gouillart
Emmanuelle Gouillart
PTPaul Tafforeau
Paul Tafforeau
JKJerome Kieffer
Jerome Kieffer

28 September 2012 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
YZYunzhe Zhao
Yunzhe Zhao
EBEmmanuel Brun
Emmanuel Brun
PCPaola Coan
Paola Coan
ZHZhifeng Huang
Zhifeng Huang
ASAniko Sztrókay
Aniko Sztrókay
ABAlberto Bravin
Alberto Bravin
Mammography is the primary imaging tool for screening and diagnosis of human breast cancers, but ∼10–20% of palpable tumors are not detectable on mammograms and only about 40% of biopsied lesions are malignant. Here we report a high-resolution, low-dose phase contrast X-ray tomographic method for 3D diagnosis of human breast cancers. By combining phase contrast X-ray imaging with an image reconstruction method known as equally sloped tomography, we imaged a human breast in three dimensions and identified a malignant cancer with a pixel size of 92 μm and a radiation dose less than that of dual-view mammography. According to a blind evaluation by five independent radiologists, our method can reduce the radiation dose and acquisition time by ∼74% relative to conventional phase contrast X-ray tomography, while maintaining high image resolution and image contrast. These results demonstrate that high-resolution 3D diagnostic imaging of human breast cancers can, in principle, be performed at clinical compatible doses.

14 December 2016 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
MCMarine Cotte
Marine Cotte
EPEmeline Pouyet
Emeline Pouyet
MSMurielle Salomé
Murielle Salomé
CRCamille RIVARD
Camille RIVARD
WNWout De Nolf
Wout De Nolf
JSJean Susini
Jean Susini
ID21 beamline (ESRF) offers combination of μXRF, μXANES (2.0–9.1 keV), μXRD and μFTIR, increasingly used to analyse artistic and ancient materials.

20 January 2015 in Nature Communications
Verified
Journal Article
Open access
PDF file
VMVito Mocella
Vito Mocella
EBEmmanuel Brun
Emmanuel Brun
CFClaudio Ferrero
Claudio Ferrero
DDDaniel Delattre
Daniel Delattre
Hundreds of papyrus rolls, buried by the eruption of Mount Vesuvius in 79 AD and belonging to the only library passed on from Antiquity, were discovered 260 years ago at Herculaneum. These carbonized papyri are extremely fragile and are inevitably damaged or destroyed in the process of trying to open them to read their contents. In recent years, new imaging techniques have been developed to read the texts without unwrapping the rolls. Until now, specialists have been unable to view the carbon-based ink of these papyri, even when they could penetrate the different layers of their spiral structure. Here for the first time, we show that X-ray phase-contrast tomography can reveal various letters hidden inside the precious papyri without unrolling them. This attempt opens up new opportunities to read many Herculaneum papyri, which are still rolled up, thus enhancing our knowledge of ancient Greek literature and philosophy.

1 July 2013 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
ABAudrey Bouchet
Audrey Bouchet
BLBenjamin Lemasson
Benjamin Lemasson
TCThomas Christen
Thomas Christen
MPMarine Potez
Marine Potez
CRClaire ROME
Claire ROME
RSRaphael Serduc
Raphael Serduc

23 September 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LQLaurène Quénot
Laurène Quénot
SBSylvain Bohic
Sylvain Bohic
EBEmmanuel Brun
Emmanuel Brun
Since the seminal work of Roentgen, X-ray imaging mainly uses the same physical phenomenon: the absorption of light by matter. Thanks to third-generation synchrotrons that provide a high flux of quasi-coherent X-rays, we have seen in recent years new imaging concepts such as phase contrast or dark-field imaging that were later adapted to conventional X-ray sources. These innovative imaging techniques are particularly suitable for visualizing soft matter, such as biological tissues. After a brief introduction to the physical foundations of these two techniques, we present the different experimental set-ups that are now available to produce such contrasts: propagation, analyzer-based, grating interferometry and non-interferometric methods, such as coded aperture and modulation techniques. We present a comprehensive review of their principles; associated data processing; and finally, their requirements for their transfer outside of synchrotrons. In conclusion, gratings interferometry, coded aperture and modulation techniques seem to be the best candidates for the widespread use of phase contrast and dark-field imaging on low-cost X-ray sources.