Laurène Quénot

Mrs. Laurène Quénot

Université Grenoble Alpes, Grenoble, Auvergne-Rhône-Alpes, France
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LQLaurène Quénot
Laurène Quénot
SBSylvain Bohic
Sylvain Bohic
EBEmmanuel Brun
Emmanuel Brun
Since the seminal work of Roentgen, X-ray imaging mainly uses the same physical phenomenon: the absorption of light by matter. Thanks to third-generation synchrotrons that provide a high flux of quasi-coherent X-rays, we have seen in recent years new imaging concepts such as phase contrast or dark-field imaging that were later adapted to conventional X-ray sources. These innovative imaging techniques are particularly suitable for visualizing soft matter, such as biological tissues. After a brief introduction to the physical foundations of these two techniques, we present the different experimental set-ups that are now available to produce such contrasts: propagation, analyzer-based, grating interferometry and non-interferometric methods, such as coded aperture and modulation techniques. We present a comprehensive review of their principles; associated data processing; and finally, their requirements for their transfer outside of synchrotrons. In conclusion, gratings interferometry, coded aperture and modulation techniques seem to be the best candidates for the widespread use of phase contrast and dark-field imaging on low-cost X-ray sources.

3 November 2021 in Optica
Verified
Journal Article
Closed access
LQLaurène Quénot
Laurène Quénot
HRHélène Rougé-Labriet
Hélène Rougé-Labriet
SBSylvain Bohic
Sylvain Bohic
SBSebastien Berujon
Sebastien Berujon
EBEmmanuel Brun
Emmanuel Brun
X-ray phase contrast imaging (PCI) has shown great potential for clinical investigation of soft tissues. However, most of the existing X-ray PCI modalities require either a partially coherent source such as a synchrotron or complex setups that are barely compatible with low-dose and patient tomography. This work demonstrates the possibility to efficiently achieve PCI on a low coherence system with a conventional X-ray tube and a detector compatible with a clinical routine. This was accomplished by adapting the speckle-based imaging setup and the numerical phase retrieval processing methods to the low coherence and the low resolution of the experiment.

2 November 2021 in Physical Review A
Verified
Journal Article
Closed access
PDF file
KPKonstantin M. Pavlov
Konstantin M. Pavlov
DPDavid M. Paganin
David M. Paganin
KMKaye S. Morgan
Kaye S. Morgan
HLHeyang Li
Heyang Li
SBSebastien Berujon
Sebastien Berujon
EBEmmanuel Brun
Emmanuel Brun
When a macroscopic-sized noncrystalline sample is illuminated using coherent x-ray radiation, a bifurcation of photon energy flow may occur. The coarse-grained complex refractive index of the sample may be considered to attenuate and refract the incident coherent beam, leading to a coherent component of the transmitted beam. Spatially unresolved sample microstructure, associated with the fine-grained components of the complex refractive index, introduces a diffuse component to the transmitted beam. This diffuse photon-scattering channel may be viewed in terms of position-dependent fans of ultrasmall-angle x-ray scatter. These position-dependent fans, at the exit surface of the object, may under certain circumstances be approximated as having a locally elliptical shape. By using an anisotropic-diffusion Fokker-Planck approach to model this bifurcated x-ray energy flow, we show how all three components (attenuation, refraction, and locally elliptical diffuse scatter) may be recovered. This is done via x-ray speckle tracking, in which the sample is illuminated with spatially random x-ray fields generated by coherent illumination of a spatially random membrane. The theory is developed and then successfully applied to experimental x-ray data.

3 September 2021 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
LQLaurène Quénot
Laurène Quénot
EBEmmanuel Brun
Emmanuel Brun
Jean Michel LétangJean Michel Létang
Jean Michel Létang
MLMax Langer
Max Langer
X-ray phase contrast imaging (PCI) denotes a group of highly sensitive imaging techniques that permits imaging at scales ranging from nanoscopic to the medical. Recently introduced, speckle-based imaging has seen a rapid development because of its experimental simplicity and its capability to retrieve the refraction, the scattering and the absorption of a sample using a conventional x-ray set-up. Precise simulation would permit to optimise the imaging setups for different applications, but until now works on simulation of x-ray speckle-based PCI have been very few. In this work we evaluate different simulation codes, based on Monte-Carlo, analytical ray-tracing and wave-optics Fresnel propagation. The simulation results are compared to both synchrotron and conventional imaging experiments to permits their validation. We obtain a strong similarity between simulated and experimental data. We discuss the validity and applicability of each approach.

2 November 2023 in Optics Letters
Verified
Journal Article
Closed access
CMClara Magnin
Clara Magnin
LQLaurène Quénot
Laurène Quénot
SBSylvain Bohic
Sylvain Bohic
DCDan Mihai Cenda
Dan Mihai Cenda
MMManuel Fernández Martínez
Manuel Fernández Martínez
EBEmmanuel Brun
Emmanuel Brun
Phase-contrast imaging, dark-field, and directional dark-field imaging are recent x ray imaging modalities that have been demonstrated to reveal different information and contrast from those provided by conventional x ray imaging. Access to these new types of images is currently limited because the acquisitions require coherent sources such as synchrotron radiation or complicated optical setups. This Letter demonstrates the possibility of efficiently performing phase-contrast, dark-field, and directional dark-field imaging on a low-coherence laboratory system equipped with a conventional x ray tube, using a simple, fast, and robust single-mask technique.

1 January 2025 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
RCRafael Celestre
Rafael Celestre
LQLaurène Quénot
Laurène Quénot
CNChristopher Ninham
Christopher Ninham
EBEmmanuel Brun
Emmanuel Brun
LFLuca Fardin
Luca Fardin
X-ray speckles have been used in a wide range of experiments, including imaging (and tomography), wavefront sensing, spatial coherence measurements, X-ray photon correlation spectroscopy and ptychography. In this review and experimental comparison, we focus on using X-ray near-field speckle grains as wavefront markers and numerical methods for retrieving the phase information they contain. We present the most common tracking methods, introducing the existing algorithms with their specifications and comparing their performances under various experimental conditions. This comparison includes applications to different types of samples: phantoms for quantitative analysis and complex samples for assessing image quality. Our goal is to unify concepts from several speckle tracking methods using consistent terminology and equation formalism, while keeping the discussion didactic and accessible to a broad audience.