Mohammad Zuber

Dr. Mohammad Zuber


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2014 in Microelectronics Reliability
Verified
Journal Article
Closed access
SSS.F. Sufian
S.F. Sufian
ZFZ.M. Fairuz
Z.M. Fairuz
MZMohammad Zuber
Mohammad Zuber
M AbdullahM Abdullah
M Abdullah
JMJ.J. Mohamed
J.J. Mohamed

1 February 2013 in Energy
Verified
Journal Article
Closed access
AIAhmad Kamal Ismail
Ahmad Kamal Ismail
MZMohammad Zuber
Mohammad Zuber
ZAzainal arifin ahmad
zainal arifin ahmad
AJAbdul Rashid Jamaludin
Abdul Rashid Jamaludin
KMKhairil Faizi MUSTAFA
Khairil Faizi MUSTAFA
M AbdullahM Abdullah
M Abdullah

1 September 2021 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
Chethan K NChethan K N
Chethan K N
SBShyamasunder N Bhat
Shyamasunder N Bhat
MZMohammad Zuber
Mohammad Zuber
Satish Shenoy B.Satish Shenoy B.
Satish Shenoy B.

1 March 2014 in International Communications in Heat and Mass Transfer
Verified
Journal Article
Closed access
ZFZ.M. Fairuz
Z.M. Fairuz
SSS.F. Sufian
S.F. Sufian
M AbdullahM Abdullah
M Abdullah
MZMohammad Zuber
Mohammad Zuber
MAM.S. Abdul Aziz
M.S. Abdul Aziz

13 March 2022 in Cogent Engineering
Verified
Journal Article
Open access
ABAniket Kunal Bhawe
Aniket Kunal Bhawe
KSKavish Maulik Shah
Kavish Maulik Shah
SSSamridhi Somani
Samridhi Somani
Satish Shenoy B.Satish Shenoy B.
Satish Shenoy B.
SBShyamasunder N Bhat
Shyamasunder N Bhat
Chethan K NChethan K N
Chethan K N
The total hip prosthesis is considered one of the greatest advancements in orthopaedic surgery in the early 20th century. In hip implant replacement, the stem is inserted into the femur and femoral head, acetabular cup, and backing cup over the stem. This felicitates the normal range of motion and stability of an individual compared to the natural hip joint. Several different types of biomaterials are used in the total hip prosthesis. Where the combination of UHMWPE, CoCrMo alloy, and Ti-6Al-4 V alloy is widely used due to their superior mechanical properties over the others. In this work, these material combinations are used for the analysis with changes in the femoral head sizes from 24 mm to 48 mm to know the best size with the better material combination. Static structural analyses are carried out using Ansys R-19. Two sets of analyses are performed for two different material combinations between Ti-6Al-4 V, CoCr, and UHMWPE. The circular cross-shaped stem with change in femoral head sizes from 24 mm to 48 mm is used for analysis. The acetabular cup and backing cup thickness are kept constant throughout the study. The size of the acetabular cup and backing cup is considered 6 mm and 4 mm respectively. Loading and boundary conditions are considered as per the ASTM standards. Hip implant with Ti-6Al-4 V for stem and a 4 mm backing cup of CoCr and 6 mm acetabular cup of UHMWPE shown the least stress value of 203.48 MPa over all the other models which are used in the analysis. This work shows the analysis to know the effect of the change in femoral head size and also the change in material combinations used in hip implants. Further experimental work can be carried out to validate the results obtained in the current work.

24 October 2023 in Energy Conversion and Management
Verified
Journal Article
Closed access
JRJayakrishnan Radhakrishnan
Jayakrishnan Radhakrishnan
SSSurya Sridhar
Surya Sridhar
MZMohammad Zuber
Mohammad Zuber
Eddie YK NgEddie YK Ng
Eddie YK Ng
Satish Shenoy B.Satish Shenoy B.
Satish Shenoy B.