Chethan K N

Dr. Chethan K N

School of Mechanical Engineering, Manipal Institute of Technology, Manipal, India
+1
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2019 in Heliyon
Verified
Journal Article
Open access
Chethan K NChethan K N
Chethan K N
MZMohammad Zuber
Mohammad Zuber
SBShyamasunder N Bhat
Shyamasunder N Bhat
Satish Shenoy B.Satish Shenoy B.
Satish Shenoy B.
CKChandrakant R. Kini
Chandrakant R. Kini
The Hip joint is the primary joint which gives stability to the human body. The wear and tear associated with age and other factors, require these joints to be replaced by implants using hip arthroplasty surgeries. Cobalt chromium alloy (CoCr), titanium alloy, stainless steel are some of the most common hip joint materials used for hip implants. The design requirement for hip joint implants are very stringent to avoid revision joint surgeries due to aseptic loosening. There are various choices in shapes and materials used for stem and acetabular designs. This makes it more difficult to make an informed decision on the type of design and material that can be used for hip implants. Circular, Oval, ellipse and trapezoidal designs with three individual cross sections (defined as profile 1, profile 2 and profile 3) are considered for the study. All models are modeled using CATIA V-6. Static structural analysis is performed using ANSYS R-19 to arrive at the best possible design and material combination for stem and acetabular cup. It was found that, profile 2 of all the four designs has the lowest possible deformation and von Mises stress when compared to profile 1 and profile 2. In general, profile 2 with trapezoidal stem has best outcomes in terms of its mechanical properties. Besides, stem designed with material CoCr and its associated acetabular cup with CoC (ceramic on ceramic) material can produce an implant having better properties and longer durability. CoCr was found to be the preferred choice of material for stem design. It was also observed that, irrespective of material considered for the analysis profile 2 with trapezoidal stem showcased lesser deformation and von Mises stress over the other eleven models. For analysis involving acetabular cups, CoC implants exhibited better mechanical properties over the conventional CoPE (Ceramic on polyethylene) materials such as Ultra-high molecular weight polyethylene (UHMWPE). It is inferred from the findings of this study that, the profile 2 with trapezoidal stem design made of CoCr material and acetabular cup made of CoC material is best suited for hip joint implants.

1 September 2021 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
Chethan K NChethan K N
Chethan K N
SBShyamasunder N Bhat
Shyamasunder N Bhat
MZMohammad Zuber
Mohammad Zuber
Satish Shenoy B.Satish Shenoy B.
Satish Shenoy B.

18 February 2025 in Prosthesis
Verified
Journal Article
Open access
PDF file
NNNishant V Nikam
Nishant V Nikam
Satish Shenoy B.Satish Shenoy B.
Satish Shenoy B.
Chethan K NChethan K N
Chethan K N
LKLaxmikant G Keni
Laxmikant G Keni
SSSawan Shetty
Sawan Shetty
SBShyamasunder N Bhat
Shyamasunder N Bhat
Background/Objectives: The increasing demand for total hip arthroplasty (THA), due to aging populations and active lifestyles, necessitates advancements in implant materials and design. This review evaluates the role of surface coatings in enhancing the performance, biocompatibility, and longevity of hip implants. It addresses challenges like wear, corrosion, and infection, focusing on innovative surface engineering solutions. Methods: The review analyzes various surface modification techniques, including physical vapor deposition (PVD), chemical vapor deposition (CVD), electrophoretic deposition (EPD), plasma spraying, and ion implantation. It also examines their effectiveness in improving tribological properties, biocompatibility, and resistance to infection. Computational methods such as finite element analysis (FEA) are discussed for predicting potential coating failures. Results: The findings underscore the challenges posed by wear debris and corrosion in common configurations, like metal-on-metal (MoM) and metal-on-polyethylene (MoP). Innovative coatings, such as diamond-like carbon (DLC) films and hydroxyapatite (HA) layers, demonstrate enhanced performance by reducing friction, wear, and bacterial adhesion, while promoting osteogenic cell attachment. Surface textures and optimized tribological properties further improve implant functionality. Multifunctional coatings exhibit potential in balancing biocompatibility and infection resistance. Conclusions: Surface engineering plays a critical role in advancing next-generation hip implants. The integration of advanced coatings and surface modifications enhances implant durability, reduces complications, and improves patient outcomes. Future research should focus on combining innovative materials and computational modeling to refine coating strategies for long-term success in THA.

13 March 2022 in Cogent Engineering
Verified
Journal Article
Open access
ABAniket Kunal Bhawe
Aniket Kunal Bhawe
KSKavish Maulik Shah
Kavish Maulik Shah
SSSamridhi Somani
Samridhi Somani
Satish Shenoy B.Satish Shenoy B.
Satish Shenoy B.
SBShyamasunder N Bhat
Shyamasunder N Bhat
Chethan K NChethan K N
Chethan K N
The total hip prosthesis is considered one of the greatest advancements in orthopaedic surgery in the early 20th century. In hip implant replacement, the stem is inserted into the femur and femoral head, acetabular cup, and backing cup over the stem. This felicitates the normal range of motion and stability of an individual compared to the natural hip joint. Several different types of biomaterials are used in the total hip prosthesis. Where the combination of UHMWPE, CoCrMo alloy, and Ti-6Al-4 V alloy is widely used due to their superior mechanical properties over the others. In this work, these material combinations are used for the analysis with changes in the femoral head sizes from 24 mm to 48 mm to know the best size with the better material combination. Static structural analyses are carried out using Ansys R-19. Two sets of analyses are performed for two different material combinations between Ti-6Al-4 V, CoCr, and UHMWPE. The circular cross-shaped stem with change in femoral head sizes from 24 mm to 48 mm is used for analysis. The acetabular cup and backing cup thickness are kept constant throughout the study. The size of the acetabular cup and backing cup is considered 6 mm and 4 mm respectively. Loading and boundary conditions are considered as per the ASTM standards. Hip implant with Ti-6Al-4 V for stem and a 4 mm backing cup of CoCr and 6 mm acetabular cup of UHMWPE shown the least stress value of 203.48 MPa over all the other models which are used in the analysis. This work shows the analysis to know the effect of the change in femoral head size and also the change in material combinations used in hip implants. Further experimental work can be carried out to validate the results obtained in the current work.

1 March 2023 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
CGCeline Gutmann
Celine Gutmann
NSNuma Shaikh
Numa Shaikh
Satish Shenoy B.Satish Shenoy B.
Satish Shenoy B.
NBN Shaymasunder Bhat
N Shaymasunder Bhat
LKLaxmikant G Keni
Laxmikant G Keni
Chethan K NChethan K N
Chethan K N
The hip joint helps the upper body to transfer its weight to lower body. Along with age, there are various reasons for the degeneration of the hip joint. The artificial hip implant replaces the degenerated hip. Wear between the joints is the primary cause of the hip implant becoming loose. The wear can occur due to various reasons. Due to this revision surgery are most common in young and active patients. In the design phase of the implant if this is taken care then life expectancy of the implant can be improved. Small design changes can significantly enhance the implant’s life. In this work, elliptical-shaped hip implant stem is designed, and linear wear is estimated at trunnion junction. In this work, a 28 mm diameter femoral head with a 4 mm thick acetabular cup and a 2 mm thick backing cup is used. The top surface taper radiuses are changed. Solid works was used to create the models. Ansys was used to perform the analysis. It was found that as the radius of the TTR decreased, the wear rate decreased. The least wear rate was found in 12/14 mm taper with a value of 1.15E−02 mm year−1 for the first material combination and with a value of 1.23E −02 mm year−1 for the second material combination. In the comparison between the models with 1 mm chamfer and no chamfer, it was found that the wear rate was lower for the models with 1 mm chamfer. When the chamfer was increased (more than 1 mm), the linear wear increased. Wear is the main reason for the loosening of hip implants, which leads to a revision of an implant. It was found that with a decrease in TTR, there was a small increase in the linear wear rate. Overall, the implant with TTR 6 mm and a chamfer of 1 mm was found to have the least wear rate. To validate these results, the implant can be 3D printed and tested on a hip simulator.

29 January 2020 in Cogent Engineering
Verified
Journal Article
Open access
Chethan K NChethan K N
Chethan K N
MZMohammad Zuber
Mohammad Zuber
SBShyamasunder N Bhat
Shyamasunder N Bhat
Satish Shenoy B.Satish Shenoy B.
Satish Shenoy B.
Hip implants consist of a stem, femoral head, acetabular cup, and backing cup. There is a wide variety of sizes and lengths. Their adaptability is limited because of the inter-anatomical variations. There is no single fit-for-all implant design that satisfies the orthopedic requirement satisfactorily. In this work, the trapezoidal-shaped stem with three different cross-sections is considered. The femoral head size, acetabular cup thickness, backing cup thickness, and trunnion geometry were varied to arrive at the best possible combination. ANSYS R-19 was used to perform the static analysis. It is found that trapezoidal-shaped profile two has the least amount of stress and total deformation. The von Mises stresses were found to be higher when the femoral head size was between 32 mm to 40 mm in profile two. It was also observed that the femoral head with 24 mm has the least stress compared to higher head sizes. The maximum von Mises stress-induced in profile two was 141.0 MPa, the total deformation of 0.04436 mm and elastic strain of 7.6 × 10−4 mm/mm. Trunnion interface does not have a significant role with respect to the structural strength of the implant. From the findings of this study, it is inferred that profile two shaped stems with the femoral ball size of 36 mm, acetabular cup thickness of 2 mm and backing cup thickness of 1mm is best suited for the hip replacement. The major outcome of this study is the utilization of the DoE method to determine the optimized value of the implant.