Diyar Saeed

Dr. Diyar Saeed

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2023 in The Journal of Heart and Lung Transplantation
Verified
Journal Article
Closed access
DSDiyar Saeed
Diyar Saeed
DFDavid Feldman
David Feldman
ABAly El Banayosy
Aly El Banayosy
EBEmma Birks
Emma Birks
EBElizabeth Blume
Elizabeth Blume
DDDavid D'ALessandro
David D'ALessandro

30 November 2023 in European Heart Journal
Verified
Journal Article
Open access
PDF file
JSJan D. Schmitto
Jan D. Schmitto
SSSteven Shaw
Steven Shaw
JGJens Garbade
Jens Garbade
FGFinn Gustafsson
Finn Gustafsson
MMMichiel Morshuis
Michiel Morshuis
DSDiyar Saeed
Diyar Saeed
Background and Aims: HeartMate 3 (HM3) is a fully magnetically levitated continuous flow left ventricular assist device, which received CE marking in 2015. The ELEVATE Registry was initiated to collect real-world outcomes in patients treated with HM3 post-CE Mark approval. Methods: A total of 540 subjects implanted at 26 centres between March 2015 and February 2017 were included in this registry. Of these, 463 received the device as a primary implant (primary implant cohort, PIC), 19 as a pump exchange (pump exchange cohort), and in 58 patients, only anonymized survival data were collected (anonymized cohort, AC). Patients in the PIC contributed to the baseline demographics, survival, adverse events, quality of life (QoL) (EuroQoL-5 Dimensions-5 Levels visual analogue scale), and functional capacity (6 min walk distance) assessments, while patients in the AC contributed only to survival. Results: Primary implant cohort patients had a mean age of 56 years and were predominantly male (89%) with 48% ischaemic aetiology. The majority of subjects was designated bridge to transplant (66%) and had INTERMACS Profiles 1–3 (70%). At baseline, the subjects had poor functional capacity (104 ± 140 m) and impaired QoL (35 ± 19 points). The overall survival rate of the PIC was 63.3% and survival free of stroke was 58.1% at 5 years. Significant improvements in functional capacity and QoL were observed and maintained for 5 years (301 ± 131 m and 64 ± 20 points, respectively). Conclusions: Real-world data from the ELEVATE registry demonstrate an overall survival rate for primary implants of 63.3%. In the PIC, reductions in adverse events for patients in the extended follow-up and improved QoL and functional capacity were observed at 5 years in this patient population with advanced heart failure.

14 October 2020 in European Heart Journal
Verified
Journal Article
Closed access
Daniel ZimpferDaniel Zimpfer
Daniel Zimpfer
FGFinn Gustafsson
Finn Gustafsson
EPEvgenij Potapov
Evgenij Potapov
YPYuriy Pya
Yuriy Pya
JSJan Schmitto
Jan Schmitto
JGJens Garbade
Jens Garbade
Aims: The ELEVATE Registry was designed to study long-term outcomes with the Heartmate 3 (HM3), a fully magnetically levitated centrifugal ventricular assist device, in a real-world population following CE-mark approval. Methods and results: A total of 540 patients, implanted in Europe and the Middle East were followed in ELEVATE. The registry included 463 patients receiving the HM3 as primary implant (Primary Implant Cohort), 19 patients underwent a pump upgrade from another device (Pump Exchange Cohort) and 58 patients who had experienced an outcome before having the possibility to sign the Informed Consent, for which only outcome data were collected (Anonymized Cohort). Data collection included demographics, survival, adverse events, EQ-5D Visual Analog Score quality of life (EQ-5D VAS QOL) questionnaire, and 6-min walk distance (6MWD). Mean age was 55.6 ± 11.7 years (89% male, 48% ischaemic cardiomyopathy). Seventy per cent of patients were in INTERMACS Profile 1–3 and 12.7% were on temporary mechanical circulatory support. Primary Implant Cohort survival was 83% after 2 years. In the Powered by Editorial Manager® and ProduXion Manager® from Aries Systems Corporation Primary Implant Cohort, strokes were observed in 10.2%, gastrointestinal bleedings in 9.7%, pump thrombosis in 1.5%, and outflow graft twists in 3.5%. Heartmate 3 implantation resulted in a significant and sustained improvement of functional capacity and QOL. Conclusion: In a real-world population, cohort implanted with the HM3 left ventricular assist device we demonstrate good long-term survival, sustained improvement of functional capacity, and low rates of adverse events (including pump thrombosis). ClinicalTrials.gov Identifier: NCT02497950

18 July 2023 in Journal of the American Heart Association
Verified
Journal Article
Open access
SMSilvia Mariani
Silvia Mariani
SHSam Heuts
Sam Heuts
BBBas Van Bussl
Bas Van Bussl
Michele Di MauroMichele Di Mauro
Michele Di Mauro
Dominik WiedemannDominik Wiedemann
Dominik Wiedemann
MSMarco Solinas
Marco Solinas
Background: Extracorporeal membrane oxygenation (ECMO) has been increasingly used for postcardiotomy cardiogenic shock, but without a concomitant reduction in observed in‐hospital mortality. Long‐term outcomes are unknown. This study describes patients’ characteristics, in‐hospital outcome, and 10‐year survival after postcardiotomy ECMO. Variables associated with in‐hospital and postdischarge mortality are investigated and reported. Methods and Results: The retrospective international multicenter observational PELS‐1 (Postcardiotomy Extracorporeal Life Support) study includes data on adults requiring ECMO for postcardiotomy cardiogenic shock between 2000 and 2020 from 34 centers. Variables associated with mortality were estimated preoperatively, intraoperatively, during ECMO, and after the occurrence of any complications, and then analyzed at different time points during a patient's clinical course, through mixed Cox proportional hazards models containing fixed and random effects. Follow‐up was established by institutional chart review or contacting patients. This analysis included 2058 patients (59% were men; median [interquartile range] age, 65.0 [55.0–72.0] years). In‐hospital mortality was 60.5%. Independent variables associated with in‐hospital mortality were age (hazard ratio [HR], 1.02 [95% CI, 1.01–1.02]) and preoperative cardiac arrest (HR, 1.41 [95% CI, 1.15–1.73]). In the subgroup of hospital survivors, the overall 1‐, 2‐, 5‐, and 10‐year survival rates were 89.5% (95% CI, 87.0%–92.0%), 85.4% (95% CI, 82.5%–88.3%), 76.4% (95% CI, 72.5%–80.5%), and 65.9% (95% CI, 60.3%–72.0%), respectively. Variables associated with postdischarge mortality included older age, atrial fibrillation, emergency surgery, type of surgery, postoperative acute kidney injury, and postoperative septic shock. Conclusions: In adults, in‐hospital mortality after postcardiotomy ECMO remains high; however, two‐thirds of those who are discharged from hospital survive up to 10 years. Patient selection, intraoperative decisions, and ECMO management remain key variables associated with survival in this cohort. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03857217.

1 December 2020 in JACC
Verified
Journal Article
Closed access
DSDiyar Saeed
Diyar Saeed
EPEvgenij Potapov
Evgenij Potapov
Antonio LoforteAntonio Loforte
Antonio Loforte
MMMichiel Morshuis
Michiel Morshuis
DSDavid Schibilsky
David Schibilsky
JGJan Gummert
Jan Gummert

12 February 2022 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
PDF file
TBTheo M M H de By
Theo M M H de By
FSFelix Schoenrath
Felix Schoenrath
KVKevin M Veen
Kevin M Veen
PMPaul Mohacsi
Paul Mohacsi
JSJulia Stein
Julia Stein
BMBart Meyns
Bart Meyns
In the third report of the European Registry for Patients with Mechanical Circulatory Support of the European Association for Cardio-Thoracic Surgery, outcomes of patients receiving mechanical circulatory support are reviewed in relation to implant era. Procedures in adult patients (January 2011–June 2020) were included. Patients from centres with <60% follow-ups completed were excluded. Outcomes were stratified into 3 eras (2011–2013, 2014–2017 and 2018–2020). Adverse event rates (AERs) were calculated and stratified into early phase (3 months). Risk factors for death were explored using univariable Cox regression with a stepwise time-varying hazard ratio (3 months). In total, 4834 procedures in 4486 individual patients (72 hospitals) were included, with a median follow-up of 1.1 (interquartile range: 0.3–2.6) years. The annual number of implants (range: 346–600) did not significantly change (P = 0.41). Both Interagency Registry for Mechanically Assisted Circulatory Support class (classes 4–7: 23, 25 and 33%; P < 0.001) and in-hospital deaths (18.5, 17.2 and 11.2; P < 0.001) decreased significantly between eras. Overall, mortality, transplants and the probability of weaning were 55, 25 and 2% at 5 years after the implant, respectively. Major infections were mainly noted early after the implant occurred (AER<3 months: 1.44 vs AER>3 months: 0.45). Bilirubin and creatinine levels were significant risk factors in the early phase but not in the late phase after the implant. In its 10 years of existence, EUROMACS has become a point of reference enabling benchmarking and outcome monitoring. Patient characteristics and outcomes changed between implant eras. In addition, both occurrence of outcomes and risk factor weights are time dependent.