Long-term mechanical circulatory support (LT-MCS) is an important treatment modality for patients with severe heart failure. Different devices are available, and many—sometimes contradictory—observations regarding patient selection, surgical techniques, perioperative management and follow-up have been published. With the growing expertise in this field, the European Association for Cardio-Thoracic Surgery (EACTS) recognized a need for a structured multidisciplinary consensus about the approach to patients with LT-MCS. However, the evidence published so far is insufficient to allow for generation of meaningful guidelines complying with EACTS requirements. Instead, the EACTS presents an expert opinion in the LT-MCS field. This expert opinion addresses patient evaluation and preoperative optimization as well as management of cardiac and non-cardiac comorbidities. Further, extensive operative implantation techniques are summarized and evaluated by leading experts, depending on both patient characteristics and device selection. The faculty recognized that postoperative management is multidisciplinary and includes aspects of intensive care unit stay, rehabilitation, ambulatory care, myocardial recovery and end-of-life care and mirrored this fact in this paper. Additionally, the opinions of experts on diagnosis and management of adverse events including bleeding, cerebrovascular accidents and device malfunction are presented. In this expert consensus, the evidence for the complete management from patient selection to end-of-life care is carefully reviewed with the aim of guiding clinicians in optimizing management of patients considered for or supported by an LT-MCS device.
1 December 2008 in The Journal of Heart and Lung Transplantation
Among other preoperative parameters, extremely low or extremely high body mass index (BMI) has been discussed as a substantial risk factor for postoperative complications after cardiac surgery. However, the exact relationship between BMI and postoperative risk has not yet been defined. We retrospectively investigated consecutive patients (n=22666) who underwent coronary artery bypass grafting with or without concomitant valve surgery between 1990 and 2001 in our institution. A number of preoperative and intraoperative variables and BMI (as a quadratic term) were used in a logistic regression model as covariates. Further, the patients were divided into 20 groups each with an increase in BMI of 1kg/m(2)(BMI as a categorical variable). The calculations of odds ratios (ORs) for re-intubation, infection, re-exploration, prolonged stay (>1 day) on the intensive care unit (ICU) and 30-day mortality were adjusted for age, gender and type of surgery. In the multivariate analysis only age (OR between 1.01 and 1.038, P<0.01), additional aortic valve (OR between 1.335 and 2.977, P<0.01) or mitral valve surgery (OR between 2.123 and 3.301, P<0.01) showed significant impact on all five end-points. Patients with BMI between 25 and 35kg/m(2)were not at elevated risk for any of the investigated end-points, except for infection. Patients with BMI between 21 and 27kg/m(2)were not at elevated risk for infection. The ORs for postoperative complications were significantly higher in underweight patients compared with obese or severely obese patients, except those for infection. Further, the underweight patients presented significantly more comorbidity. Patients with low BMI are at higher risk after cardiac surgery than obese or severely obese patients. We hypothesize that a preoperative focus on avoiding and/or reversing cachexia may be more efficacious than reducing obesity in reducing the overall risk associated with heart surgery.
Background and Aims: HeartMate 3 (HM3) is a fully magnetically levitated continuous flow left ventricular assist device, which received CE marking in 2015. The ELEVATE Registry was initiated to collect real-world outcomes in patients treated with HM3 post-CE Mark approval. Methods: A total of 540 subjects implanted at 26 centres between March 2015 and February 2017 were included in this registry. Of these, 463 received the device as a primary implant (primary implant cohort, PIC), 19 as a pump exchange (pump exchange cohort), and in 58 patients, only anonymized survival data were collected (anonymized cohort, AC). Patients in the PIC contributed to the baseline demographics, survival, adverse events, quality of life (QoL) (EuroQoL-5 Dimensions-5 Levels visual analogue scale), and functional capacity (6 min walk distance) assessments, while patients in the AC contributed only to survival. Results: Primary implant cohort patients had a mean age of 56 years and were predominantly male (89%) with 48% ischaemic aetiology. The majority of subjects was designated bridge to transplant (66%) and had INTERMACS Profiles 1–3 (70%). At baseline, the subjects had poor functional capacity (104 ± 140 m) and impaired QoL (35 ± 19 points). The overall survival rate of the PIC was 63.3% and survival free of stroke was 58.1% at 5 years. Significant improvements in functional capacity and QoL were observed and maintained for 5 years (301 ± 131 m and 64 ± 20 points, respectively). Conclusions: Real-world data from the ELEVATE registry demonstrate an overall survival rate for primary implants of 63.3%. In the PIC, reductions in adverse events for patients in the extended follow-up and improved QoL and functional capacity were observed at 5 years in this patient population with advanced heart failure.
Purpose: The use of ventricular assist devices (VADs) in patients with chronic end-stage or acute heart failure has led to improved survival. We present our experience since 1987. Subjects and Methods: Between July 1987 and December 2006, 1026 VADs were implanted in 970 patients. Most of them were men (81.9%). The indications were: cardiomyopathy (n = 708), postcardiotomy heart failure (n = 173), acute myocardial infarction (n = 36), acute graft failure (n = 45), a VAD problem (n = 6), and others (n = 2). Mean age was 46.1 (range 3 days to 78) years. In 50.5% of the patients the VAD implanted was left ventricular, in 47.9% biventricular, and in 1.5% right ventricular. There were 14 different types of VAD. A total artificial heart was implanted in 14 patients. Results: Survival analysis showed higher early mortality (p < 0.05) in the postcardiotomy group (50.9%) than in patients with preoperative profound cardiogenic shock (31.1%) and patients with preoperative end-stage heart failure without severe shock (28.9%). A total of 270 patients were successfully bridged to heart transplantation (HTx). There were no significant differences in long-term survival after HTx among patients with and without previous VAD. In 76 patients the device could be explanted after myocardial recovery. In 72 patients the aim of implantation was permanent support. During the study period 114 patients were discharged home. Currently, 54 patients are on a device. Conclusions: VAD implantation may lead to recovery from secondary organ failure. Patients should be considered for VAD implantation before profound, possibly irreversible, cardiogenic shock occurs. In patients with postcardiotomy heart failure, a more efficient algorithm should be developed to improve survival. With increased experience, more VAD patients can participate in out-patient programs.
Aims: The ELEVATE Registry was designed to study long-term outcomes with the Heartmate 3 (HM3), a fully magnetically levitated centrifugal ventricular assist device, in a real-world population following CE-mark approval. Methods and results: A total of 540 patients, implanted in Europe and the Middle East were followed in ELEVATE. The registry included 463 patients receiving the HM3 as primary implant (Primary Implant Cohort), 19 patients underwent a pump upgrade from another device (Pump Exchange Cohort) and 58 patients who had experienced an outcome before having the possibility to sign the Informed Consent, for which only outcome data were collected (Anonymized Cohort). Data collection included demographics, survival, adverse events, EQ-5D Visual Analog Score quality of life (EQ-5D VAS QOL) questionnaire, and 6-min walk distance (6MWD). Mean age was 55.6 ± 11.7 years (89% male, 48% ischaemic cardiomyopathy). Seventy per cent of patients were in INTERMACS Profile 1–3 and 12.7% were on temporary mechanical circulatory support. Primary Implant Cohort survival was 83% after 2 years. In the Powered by Editorial Manager® and ProduXion Manager® from Aries Systems Corporation Primary Implant Cohort, strokes were observed in 10.2%, gastrointestinal bleedings in 9.7%, pump thrombosis in 1.5%, and outflow graft twists in 3.5%. Heartmate 3 implantation resulted in a significant and sustained improvement of functional capacity and QOL. Conclusion: In a real-world population, cohort implanted with the HM3 left ventricular assist device we demonstrate good long-term survival, sustained improvement of functional capacity, and low rates of adverse events (including pump thrombosis). ClinicalTrials.gov Identifier: NCT02497950