Background: Extracorporeal carbon dioxide removal (ECCO2R) uses an extracorporeal circuit to directly remove carbon dioxide from the blood either in lieu of mechanical ventilation or in combination with it. While the potential benefits of the technology are leading to increasing use, there are very real risks associated with it. Several studies demonstrated major bleeding and clotting complications, often associated with hemolysis and poorer outcomes in patients receiving ECCO2R. A better understanding of the risks originating specifically from the rotary blood pump component of the circuit is urgently needed. Methods: High-resolution computational fluid dynamics was used to calculate the hemodynamics and hemocompatibility of three current rotary blood pumps for various pump flow rates. Results: The hydraulic efficiency dramatically decreases to 5–10% if operating at blood flow rates below 1 L/min, the pump internal flow recirculation rate increases 6–12-fold in these flow ranges, and adverse effects are increased due to multiple exposures to high shear stress. The deleterious consequences include a steep increase in hemolysis and destruction of platelets. Conclusions: The role of blood pumps in contributing to adverse effects at the lower blood flow rates used during ECCO2R is shown here to be significant. Current rotary blood pumps should be used with caution if operated at blood flow rates below 2 L/min, because of significant and high recirculation, shear stress, and hemolysis. There is a clear and urgent need to design dedicated blood pumps which are optimized for blood flow rates in the range of 0.5–1.5 L/min.
The use of extracorporeal life support (ECLS) devices has significantly increased in the last decades. Despite medical and technological advancements, a main challenge in the ECLS field remains the complex interaction between the human body, blood, and artificial materials. Indeed, blood exposure to artificial surfaces generates an unbalanced activation of the coagulation cascade, leading to hemorrhagic and thrombotic events. Over time, several anticoagulation and coatings methods have been introduced to address this problem. This narrative review summarizes trends, advantages, and disadvantages of anticoagulation and coating methods used in the ECLS field. Evidence was collected through a PubMed search and reference scanning. A group of experts was convened to openly discuss the retrieved references. Clinical practice in ECLS is still based on the large use of unfractionated heparin and, as an alternative in case of contraindications, nafamostat mesilate, bivalirudin, and argatroban. Other anticoagulation methods are under investigation, but none is about to enter the clinical routine. From an engineering point of view, material modifications have focused on commercially available biomimetic and biopassive surfaces and on the development of endothelialized surfaces. Biocompatible and bio-hybrid materials not requiring combined systemic anticoagulation should be the future goal, but intense efforts are still required to fulfill this purpose.
Only a very small portion of end-stage organ failures can be treated by transplantation because of the shortage of donor organs. Although artificial long-term organ support such as ventricular assist devices provide therapeutic options serving as a bridge-to-transplantation or destination therapy for end-stage heart failure, suitable long-term artificial lung systems are still at an early stage of development. Although a short-term use of an extracorporeal lung support is feasible today, the currently available technical solutions do not permit the long-term use of lung replacement systems in terms of an implantable artificial lung. This is currently limited by a variety of factors: biocompatibility problems lead to clot formation within the system, especially in areas with unphysiological flow conditions. In addition, proteins, cells, and fibrin are deposited on the membranes, decreasing gas exchange performance and thus, limiting long-term use. Coordinated basic and translational scientific research to solve these problems is therefore necessary to enable the long-term use and implantation of an artificial lung. Strategies for improving the biocompatibility of foreign surfaces, for new anticoagulation regimes, for optimization of gas and blood flow, and for miniaturization of these systems must be found. These strategies must be validated byin vitroandin vivotests, which remain to be developed. In addition, the influence of long-term support on the pathophysiology must be considered. These challenges require well-connected interdisciplinary teams from the natural and material sciences, engineering, and medicine, which take the necessary steps toward the development of an artificial implantable lung.