Andreas Kaesler

Andreas Kaesler

Auto-generated profile, based on publicly available information

Andreas Kaesler

Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2018 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
AKAndreas Kaesler
Andreas Kaesler
MRMarius Rosen
Marius Rosen
TSThomas Schmitz‐Rode
Thomas Schmitz‐Rode
USUlrich Steinseifer
Ulrich Steinseifer
Jutta ArensJutta Arens
Jutta Arens

13 February 2018 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
LSLotte Schraven
Lotte Schraven
AKAndreas Kaesler
Andreas Kaesler
CFChristian Flege
Christian Flege
RKRüdger Kopp
Rüdger Kopp
TSThomas Schmitz‐Rode
Thomas Schmitz‐Rode
Jutta ArensJutta Arens
Jutta Arens

7 December 2016 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
AKAndreas Kaesler
Andreas Kaesler
PSPeter C. Schlanstein
Peter C. Schlanstein
FHFelix Hesselmann
Felix Hesselmann
MBMartin Büsen
Martin Büsen
MKMichael Klaas
Michael Klaas
Jutta ArensJutta Arens
Jutta Arens

7 August 2018 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
AKAndreas Kaesler
Andreas Kaesler
FHFelix Hesselmann
Felix Hesselmann
MZMark O. Zander
Mark O. Zander
PSPeter C. Schlanstein
Peter C. Schlanstein
GWGeorg Wagner
Georg Wagner
Jutta ArensJutta Arens
Jutta Arens

21 June 2021 in Bio-Design and Manufacturing
Verified
Journal Article
Open access
PDF file
FHFelix Hesselmann
Felix Hesselmann
JFJannis Mathias Focke
Jannis Mathias Focke
PSPeter C. Schlanstein
Peter C. Schlanstein
NSNiklas Steuer
Niklas Steuer
AKAndreas Kaesler
Andreas Kaesler
Jutta ArensJutta Arens
Jutta Arens
Currently, artificial-membrane lungs consist of thousands of hollow fiber membranes where blood flows around the fibers and gas flows inside the fibers, achieving diffusive gas exchange. At both ends of the fibers, the interspaces between the hollow fiber membranes and the plastic housing are filled with glue to separate the gas from the blood phase. During a uniaxial centrifugation process, the glue forms the “potting.” The shape of the cured potting is then determined by the centrifugation process, limiting design possibilities and leading to unfavorable stagnation zones associated with blood clotting. In this study, a new multiaxial centrifugation process was developed, expanding the possible shapes of the potting and allowing for completely new module designs with potentially superior blood flow guidance within the potting margins. Two-phase simulations of the process in conceptual artificial lungs were performed to explore the possibilities of a biaxial centrifugation process and determine suitable parameter sets. A corresponding biaxial centrifugation setup was built to prove feasibility and experimentally validate four conceptual designs, resulting in good agreement with the simulations. In summary, this study shows the feasibility of a multiaxial centrifugation process allowing greater variety in potting shapes, eliminating inefficient stagnation zones and more favorable blood flow conditions in artificial lungs. Graphic abstract