Cast Mg-9Li alloy was successfully solid-solution (SS) treated via heating at 575 °C for 4.5 h and rapidly quenched with ice-water mixture. The mechanical property and corrosion resistance of the SS alloy were simultaneously improved. Rapid bcc/hcp phase transition of the alloy occurred during the quenching process, creating the newly precipitated needle-like fine α-Mg phase, uniformly distributed in the β-Li phase matrix. Dramatic grain refinement and uniform distribution of the α-Mg phase, as well as the massively increased α/β phase interfaces, are factors leading to the improved mechanical property of the SS alloy. Meanwhile, due to the modified duplex-phase structure, the SS alloy has a uniform corrosion-resistant surface film on the β-Li phase, which completely covers the entire alloy surface and efficiently protects the substrate. In addition, the SS alloy has fewer difference in the elements concentration and corrosion activity of the duplex phases, which reduces the pitting sensitivity and improves the corrosion resistance of the alloy matrix. The findings in this binary Mg-Li alloy can also serve as a benchmark for other more practical and complicated Mg-Li alloys.
Macrocell corrosion of steel rebar in concrete induced by corrosive environments has attracted widespread attention in the engineering community due to its rapid corrosion rate, diverse forms, and multiple incentives. Potential differences between dissimilar coupled rebar or different parts of the same rebar mainly cause macrocell corrosion of steel rebar. The more significant the potential difference, the faster the corrosion rate of the macrocell. Based on the existing research reports on macrocell corrosion of reinforced concrete, this review paper comprehensively discusses the macro- and micro-corrosion behavior of various types of steel rebar, and a variety of induction factors, such as dissimilar metals and concentration differences of the service environment, development rules. and electrochemical mechanisms for corrosion of rebar macrocells are summarized. ZRA (zero-resistance ammeter), micro-area electrochemical testing technology and evaluation techniques commonly used in the laboratory, and electrochemical testing techniques used in engineering testing are listed. Common experimental models for corrosion of rebar macrocells are briefly introduced. Based on the internal characteristics of macrocell corrosion of reinforced concrete, this paper further proposes the control strategy of macrocell corrosion, starting from the improvement of the corrosion resistance of the rebar and regulating the service environment of the reinforced concrete structure (RCS). Meanwhile, the future direction of macrocell corrosion of steel rebar is also preliminarily prospected.
The formation of a corrosion-resistant coating by the hydrothermal method is an effective way to provide significant protection to magnesium alloys. However, it is a challenge to prepare such a coating on magnesium-lithium alloys because of its high chemical activity. Herein, the dual-layer structured corrosion-resistant conversion coating composed with Mg(OH)2 and LiOH was successfully synthesized on Mg-9Li alloy by the optimization of the hydrothermal reaction in deionized water. The coating synthesized at 140 °C for 2 h has the best anti-corrosion performance in all obtained coatings, which has a uniform and compact coating with thickness of about 3 μm. The improvement of the hydrophobicity due to the stacking structure of the surface layer, as well as the barrier effect of its inner compact coating on corrosive media, lead to the excellent anti-corrosion performance of the obtained hydrothermal conversion coating
In this study, a high-strength Mg-9Li alloy was developed via multi-pass equal-channel-angular-pressing (ECAP) and post rolling, of which the yield tensile stress (YTS) and ultimate tensile stress (UTS) were 166 MPa and 174 MPa representing about 219% and 70% increase in YTS and UTS respectively, compared to the cast alloy. The cast alloy was ECAP processed at 200 °C for 4, 8, and 16 passes, followed by room-temperature rolling to a total thickness reduction of 50%. The 8-passes ECAPed (E8) alloy presented the best strength of all the ECAPed alloys, and the post rolling endowed the alloy (E8R) further strengthening and the best strength of all the alloys. Grain-boundary strengthening and dislocation strengthening were the two major factors for the high strength of the processed alloys. The α-Mg phase grains were greatly refined to about 2 μm after 8-passes ECAP, and was further refined to about 800 nm ~1.5 μm after rolling. Significant grain refinement endowed the alloy with sufficient grain-boundary strengthening. Profuse intragranular dislocation accumulated in the deformed matrix, leading to the significant dislocation hardening of the alloy. Rolling-induced strong basal texture of the α-Mg phase also enhanced the further strengthening of the E8R alloy.
This work analyzes the effects of ultrafine aluminum (Al) grains on the anodizing coating reaction and anticorrosion performance of anodized industrial pure Al. Equal-channel angular pressing (ECAP) was applied to cast pure Al continuously for 16 passes at room temperature, and its average grain size was dramatically refined to about 1.5 μm. The ultrafine-grain (UFG) pure Al was further anodized with a cast sample via a parallel anodizing circuit at a constant total input current. Benefited by the higher volume fraction of grain boundaries and higher internal energy of the UFG substrate, the anodizing process of the ECAP-processed pure Al was significantly accelerated, showing a more intense initial anodizing reaction, a faster initial coating thickening, and much earlier porous-layer formation compared to the cast sample. As the anodizing reaction continued, the newly formed thicker coating of the ECAP-coated sample significantly hindered the diffusion process, weakening the thermodynamic advantage and decreasing the anodizing current of the ECAP-processed sample. During the entire anodizing duration, the ECAP-processed pure Al experienced gradually decreased anodizing current, while the cast sample experienced increased anodizing current. Because of the more total reaction, the ECAP-coated sample always maintained a relatively thicker coating and better anticorrosion performance during the entire anodizing duration.
The service of reinforced concrete structures (RCSs) in harsh coastal environments is often threatened by chloride corrosion. The penetration of chloride ions through concrete pores into the steel/concrete interface will cause the depassivation and corrosion of steel rebars, which will lead to the deterioration and failure of RCSs durability. It is important to repair and protect the corrosion damage of existing concrete structures and ensure their high durability, and the high performance of repairing and protecting materials is crucial. In this paper, a novel cement-based protective coating material with low porosity, high impermeability and chloride-corrosion resistance was designed and prepared by introducing polypropylene fiber and high-performance cement into commercial cement-based protective materials through the double modification strategy of fiber-toughening and substrate-enhancing, in order to provide a reliable corrosion protection solution for the high durability and long life of RCSs under chloride erosion environment. Based on this, the microstructure and pore structure of the double-modified coating material was systematically analyzed by SEM, XRD, X-CT and other characterization methods. The impermeability and chloride corrosion resistance of this material were scientifically evaluated, and the protection mechanism was systematically discussed. The results show that the impermeability of the double-modified coating material is about 2.8 times higher than that of the untreated mortar. At the same time, the corrosion current density was significantly reduced to 8.60 × 10−7 A·cm−2, which was about 86% lower than that of the untreated sample (6.11 × 10−6 A·cm−2). The new cement-based coating material optimized by double-modification effectively inhibits the formation and propagation of microcracks in the protective coating through the bridging effect of fibers. At the same time, the regulation of cement hydration products and the densification of pore structure are realized by adjusting the composition of cement matrix. Based on the above two aspects of microstructure improvement, the chloride-corrosion protection performance of the novel cement-based protective coating material has been greatly improved.