The ingress of body fluids or their constituents is one of the main causes of failure of active implantable medical devices (AIMDs). Progressive delamination takes its origin at the junctions where exposed electrodes and conductive pathways enter the implant interior. The description of this interface is considered challenging because electrochemically-diffusively coupled processes are involved. Furthermore, standard tests and specimens, with clearly defined 3-phase boundaries (body fluid-metal-polymer), are lacking. We focus on polymers as substrate and encapsulation and present a simple method to fabricate reliable test specimens with defined boundaries. By using silicone rubber as standard material in active implant encapsulation in combination with a metal surface, a corrosion-triggered delamination process was observed that can be universalised towards typical AIMD electrode materials. Copper was used instead of medical grade platinum since surface energies are comparable but corrosion occurs faster. The finding is that two processes are superimposed there: First, diffusion-limited chemical reactions at interfaces that undermine the layer adhesion. The second process is the influx of ions and body fluid components that leave the aqueous phase and migrate through the rubber to internal interfaces. The latter observation is new for active implants. Our mathematical description with a Stefan-model coupled to volume diffusion reproduces the experimental data in good agreement and lends itself to further generalisation.
1 October 2020 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
The combination of printed circuit boards (PCB) and microfluidics has many advantages. The combination of electrodes, sensors and electronics is needed for almost all microfluidic systems. Using PCBs as a substrate, this integration is intrinsic. Additive manufacturing has become a widely used technique in industry, research and by hobbyists. One very promising rapid prototype technique is vat polymerization with an LCD as mask, also known as masked stereolithography (mSLA). These printers are available with resolutions down to 35 µm, and they are affordable. In this paper, a technology is described which creates microfluidics on a PCB substrate using an mSLA printer. All steps of the production process can be carried out with commercially available printers and resins: this includes the structuring of the copper layer of the PCB and the buildup of the channel layer on top of the PCB. Copper trace dimensions down to 100 µm and channel dimensions of 800 µm are feasible. The described technology is a low-cost solution for combining PCBs and microfluidics.
Chemosensor technology for trace gases in the air always aims to identify these compounds and then measure their concentrations. For identification, traceable methods are sparse and relate to large appliances such as mass spectrometers. We present a new method that uses the alternative traceable measurement of the ionization energies of trace gases in a way that can be miniaturized and energetically tuned. We investigate the achievable performance. Since tunable UV sources are not available for photoionization, we take a detour via impact ionization with electrons, which we generate using the photoelectric effect and bring to sharp, defined energies on a nanoscale in the air. Electron impact ionization is thus possible at air pressures of up to 900 hPa. The sensitivity of the process reaches 1 ppm and is equivalent to that of classic PID. With sharpened energy settings, substance identification is currently possible with an accuracy of 30 meV. We can largely explain the experimental observations with the known quantum mechanical models.
The infield measurement of nutrients, heavy metals, and other contaminants in water is still a needed tool in environmental sciences. The Lab-on-a-chip approach can develop deployable instruments that use the standardized analytical assay in a miniaturized manner in the field. This paper presents a Lab-on-a-chip platform for colorimetric measurements that can be deployed for nutrient monitoring in open water (oceans, rivers, lakes, etc.). Nitrite was selected as an analyte. Change to other analytes is possible by changing the reagents and the detection wavelength. In this paper, the principle of the sensor, technical realization, setup of the sensor, and test deployment are described. The sensor prototype was deployed at the Jade Bay (German Bight) for 9 h, measuring the nitrite value every 20 min. Reference samples were taken and processed in the lab. The work presented here shows that an infield measurement using a colorimetric assay is possible by applying Lab-on-a-chip principles.
The diagnosis of several diseases can be performed by analyzing the blood plasma of a patient. Despite extensive research work, there is still a need to improve current low-cost fabrication techniques and devices for the separation of plasma from blood cells. Microfluidic biomedical devices have great potential for that process. Hence, a microfluidic device made by micromilling and sealed with an oxygen plasma technique was tested by means of two different blood analogue fluids. The device has four microchannels with similar geometries but different channel depths. A high-speed video microscopy system was used for the visualization and acquisition of the flow of the analogue fluids throughout the microchannels of the device. Then, the separation of particles and plasma was evaluated with the ImageJ software by measuring and comparing the grey values at the entrance and the exit of the channel. The device showed a significant reduction of the amount of cells between the entrance and the exit of the microchannels. The depth of the channels and the size of the particles were not found to exert any major influence on the separation process. However, it was found that the flow rate affected the separation results, as the best results were obtained for a flow rate of 100 μL/min. Though these results are promising, further analyses and optimizations of microfluidic devices, as well as comparisons between devices sealed using different methods such as the solvent bonding technique, will be conducted in future works.