Chaohui Liu

Chaohui Liu


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZSZhanfeng Song
Zhanfeng Song
YJYilin Jia
Yilin Jia
CLChaohui Liu
Chaohui Liu
Due to high power-transforming capability and excellent fault-tolerant performance, dual three-phase permanent magnet synchronous machines (DT-PMSMs) are widely used in high-reliability applications. Concerning on the remedial strategy for DT-PMSMs under open-phase faults, the conventional method is to reconfigure the controller or the current references in order to obtain optimum postfault performances. Two different control schemes should be separately designed for normal and fault conditions, respectively. Meanwhile, related fault detection measures need to be adopted and the inherent fault detection delay will further result in transient performance deterioration. In order to solve these problems, this article proposes a control strategy, which can achieve natural fault-tolerant capability of DT-PMSMs without additional fault detection algorithm. With the proposed control method adopted, reconfiguration of the control structure and modification of the current command are not required. Thus, the control scheme is simplified. The transition from the healthy to the postfault operation can be improved, meanwhile, the steady-state performances in prefault and postfault situations can be guaranteed. The proposed strategy can be generally applied to single open-phase faults and multiple open-phase faults in DT-PMSMs. Experimental validations are presented on a 1 kW DT-PMSM platform to prove the effectiveness of the proposed strategy.

22 August 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Davide CittantiDavide Cittanti
Davide Cittanti
FSFausto Stella
Fausto Stella
EVEnrico Vico
Enrico Vico
CLChaohui Liu
Chaohui Liu
JSJinliang Shen
Jinliang Shen
RBRadu Bojoi
Radu Bojoi
The drive inverter is a crucial component of an electric vehicle (EV) powertrain, being responsible for the DC/AC power conversion between the battery and the electric motor. The increasing demand for lower weight and higher conversion efficiency is opening new challenges, encouraging the adoption of new technologies (e.g., wide bandgap semiconductor devices). In particular, the DC-link capacitor typically represents the bulkiest inverter component, posing a strict limitation to the achievable converter power density and thus being subject to great pressure for improvement. In this context, novel ceramic capacitor technologies (e.g., PLZT) promise superior performance with respect to well established film-based solutions, featuring both higher specific capacitance and higher RMS current capability. Therefore, this paper focuses on the analysis, sizing, design and experimental assessment of a PLZT-based ceramic DC-link capacitor for next-generation EV drive inverters, including a comparative assessment with a state-of-the-art film-based solution. In particular, in view of the non-linear behavior of the PLZT capacitance value with respect to the DC-bias voltage and the amplitude of the excitation, a novel correlation between the effective large-signal capacitance and the peak-to-peak voltage ripple is derived experimentally, providing useful information for the DC-link capacitor sizing (i.e., not available from the capacitor manufacturer). For verification purposes, a full-scale DC-link capacitor prototype for a SiC MOSFET 800 V, 550 kVA, 20 kHz drive inverter is realized, demonstrating superior power density (i.e., $\approx$ two thirds smaller and $\approx$ one third lighter than a corresponding film-based solution). Finally, the inverter prototype is also exploited to validate experimentally the proposed DC-link peak-to-peak voltage ripple estimation procedure, based on the newly obtained large-signal capacitance characterization.

28 October 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
FLFanfan Lin
Fanfan Lin
Xin ZhangXin Zhang
Xin Zhang
XLXinze Li
Xinze Li
CLChaohui Liu
Chaohui Liu
HMHao Ma
Hao Ma
The symmetrical CLLC-type DC transformer (DCT) has been widely adopted in DC microgrid for its high power density and outstanding bidirectional power transfer capacity. However, the practical values of the inductors and capacitors in the circuit may fluctuate because of variations of temperature and power, which results in some challenges for the parameter design of the CLLC-type DCT to meet the following two design requirements. Firstly, the CLLC-type DCT is expected to maintain stable when it is cascaded with a constant power load (CPL) even if its output impedance is affected by fluctuating values of inductors and capacitors. Secondly, the CLLC-type DCT is expected to maintain satisfactory power efficiency even if the inductors or capacitors fluctuate. To meet both design requirements, cascaded system stability and satisfactory power efficiency, this paper proposes a four-stage PSO-aided parameter design approach for the CLLC-type DCT which fully considers the unpredictable fluctuations of practical inductors and capacitors. With this proposed approach, even if the values of inductors or capacitors fluctuate, the CLLC-type DCT can work stably when it is cascaded with CPL and meet power efficiency requirement. Finally, the effectiveness of the proposed four-stage PSO-aided parameter design approach has been experimentally verified.

8 May 2024 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
JYJun Yan
Jun Yan
XWXimeng Wu
Ximeng Wu
Z. Q. ZhuZ. Q. Zhu
Z. Q. Zhu
CLChaohui Liu
Chaohui Liu
This paper proposes an improved extended EMF (EEMF)-based sensorless control method for permanent magnet synchronous machine drive systems with a small dc-link capacitor, while considering the dc-link voltage measurement error. Due to fluctuating dc-link voltage, precise and stable dc-link voltage information is extremely important. It is demonstrated that the dc-link voltage measurement error will introduce a dc offset in the estimated position error under EEMF-based sensorless control. To address this issue, a dc-link voltage observer is proposed in this paper, which is immune to dc-link voltage measurement error and estimated position error. Specifically, the estimated position error caused by the dc-link voltage measurement error can be eliminated by using the estimated dc-link voltage. Meanwhile, to further improve the realism and practicality of the proposed observer, the magnetic saturation effect is analysed using finite element analysis. It is found that the parameter mismatch has only a minor effect on the proposed observer. In addition, this paper identifies the coupling issue introduced by using the estimated dc-link voltage in the EEMF-based sensorless control strategy and a back-EMF harmonic suppression method is proposed to suppress the harmonics in the estimated back-EMF, speed, position error, and dc-link voltage, thereby eliminating the coupling issue. A satisfactory system control performance can be achieved, which is validated by experiments.

4 July 2024 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Hui YangHui Yang
Hui Yang
YMYanchun Mao
Yanchun Mao
SLShukang Lyu
Shukang Lyu
HLHeyun Lin
Heyun Lin
ZCZhiyong Chen
Zhiyong Chen
CLChaohui Liu
Chaohui Liu
The concept of asymmetric magnetic pole (AMP) has been developed to further improve the torque density of interior permanent magnet (IPM) machines. Compared with the conventional IPM machine, the AMP-IPM machine exhibits different operating characteristics in different rotating directions due to its unique magnetic-field-shifting (MFS) effect. Therefore, this article investigates the operating characteristics of AMP-IPM machine with aligned magnet and reluctance torques. To obtain the torque–speed relations, the maximum torque per ampere (MTPA) control method is studied. It shows that the MTPA trajectory obtained from AMP-IPM machine mathematical model is straight, which significantly simplifies the control efforts. On this basis, the torque–speed curves over the entire operating region are then analytically derived and compared, which indicate that AMP-IPM machine in low-speed region exhibits large peak torque in forward direction, while the machine in reverse direction is suitable for wide-speed range operation. Besides, the electromagnetic performances of the AMP-IPM machine are compared with those of the conventional IPM machine to further highlight the particular impact of MFS effect. The experimental results on an AMP-IPM prototype are obtained to verify all the theoretical analyses.

23 June 2025 in IEEE Transactions on Industry Applications
Verified
Journal Article
Open access
FTFurkan Tokgoz
Furkan Tokgoz
Z. Q. ZhuZ. Q. Zhu
Z. Q. Zhu
XCXiao Chen
Xiao Chen
CLChaohui Liu
Chaohui Liu
LYLianghui Yang
Lianghui Yang
YHYiming Huang
Yiming Huang
The feasibility of utilizing multiphase machines in electrical vehicles (EVs) is investigated in this paper by designing three-phase, five-phase, six-phase, and nine-phase interior permanent magnet synchronous machines (IPMSMs) with the same sizing parameters as the Tesla Model 3 IPMSM which is used as a reference. The optimized three-phase machine results in a 20% higher average output torque per permanent magnet (PM) volume compared to the reference design. Multiphase machines show 3-5% higher torque per PM volume over their three-phase counterpart while achieving inherently low torque ripples. The torque-speed analysis of the multiphase machines demonstrates enhanced efficiency regions attributable to the increased output power although this improvement is accompanied by increased iron losses due to high winding factors of harmonics. PWM losses are calculated, and thermal simulations of the machines are performed to validate that the designs work with thermal limitations. It is also shown that the DC-link capacitor size can be reduced by up to 55% compared to a three-phase system by using a multiphase structure. The total number of power switches used in the drive remains the same for the six-phase machine since the lower phase currents can be achieved by increasing the number of phases. The cost analysis for each of the machines has shown that multiphase machines are not necessarily more expensive than three-phase machines since the same total number of switches considering paralleled switches in three-phase machine can be used in six-phase machine while having smaller DC-link capacitors and PM volume. As a result, 14.2% higher output power per cost can be achieved compared to the reference design.