Gordon T. Kennedy

Dr. Gordon T. Kennedy


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2021 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
TPThinh Phan
Thinh Phan
RRRebecca Rowland
Rebecca Rowland
APAdrien Ponticorvo
Adrien Ponticorvo
BLBinh C. Le
Binh C. Le
RWRobert H. Wilson
Robert H. Wilson
ADAnthony J. Durkin
Anthony J. Durkin
Diffuse optical spectroscopic (DOS) techniques have been widely used to obtain in vivo tissue optical properties.1,2 Using light transport models in the temporal and spatial domains, these techniques can quantify tissue absorption and scattering.3 – 5 Specifically, DOS techniques quantify the wavelength-dependent tissue reduced scattering (μs′) and absorption (μa) coefficients, which can be used to deduce subsurface structural and functional information. Recently, researchers have used μs′ to noninvasively assess wound healing.6 – 8 In a porcine burn model, we previously showed that μs′ may accurately predict burn severity and skin wound healing capabilities.9 – 11 Although these results showed promise for a potential new approach to rapidly assess burn severity and prognosticate wound healing, translating this technique to human subjects necessitates an understanding of baseline μs′ values in human skin. Thus, it is important to document μs′ values of normal skin at commonly used DOS wavelengths (visible- and near-infrared) for various anatomical locations and levels of pigmentation.

1 April 2020 in Burns Open
Verified
Journal Article
Open access
APAdrien Ponticorvo
Adrien Ponticorvo
RRRebecca Rowland
Rebecca Rowland
MBMelissa Baldado
Melissa Baldado
GKGordon T. Kennedy
Gordon T. Kennedy
AHAnna-Marie Hosking
Anna-Marie Hosking
ADAnthony J. Durkin
Anthony J. Durkin
While visual assessment by a clinician is the standard of care for burn severity evaluations, new technologies at various stages of development are attempting to add objectivity to this practice by quantifying burn severity. Assessment accuracy generally improves after the burn injury has progressed, but early assessments that correctly identify superficial partial and deep partial burns have the potential to lead to more prompt treatments and shorter recovery times. To date, Spatial Frequency Domain Imaging (SFDI) has only been used in animal models of burns, but has shown the potential to categorize burns accurately at earlier time points. Here we examine the potential for SFDI to assess burn severity in clinical patients. We also utilize Laser Speckle Imaging (LSI), an FDA cleared non-invasive imaging technology that typically measures blood perfusion in order to evaluate burns in clinical patients. We present a case series of two patients, both with partial thickness burns of varying severity. Partial thickness burns are often difficult for clinicians to categorize based on visual appearance alone. SFDI and LSI were both performed on each patient at approximately 24 and 72 h after their respective burn incidents. Each technique was able to render spatially resolved information that enabled improved assessment accuracy for each burn. This represents the first publication of SFDI applied to clinical burn patients after being successfully utilized in animal models, and highlights the potential for SFDI as a feasible tool for the timely categorization of burn severity.

27 May 2019 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
RRRebecca A. Rowland
Rebecca A. Rowland
APAdrien Ponticorvo
Adrien Ponticorvo
MBMelissa L. Baldado
Melissa L. Baldado
GKGordon T. Kennedy
Gordon T. Kennedy
DBDavid Burmeister
David Burmeister
ADAnthony J. Durkin
Anthony J. Durkin
Accurate assessment of burn severity is critical for wound care and the course of treatment. Delays in classification translate to delays in burn management, increasing the risk of scarring and infection. To this end, numerous imaging techniques have been used to examine tissue properties to infer burn severity. Spatial frequency-domain imaging (SFDI) has also been used to characterize burns based on the relationships between histologic observations and changes in tissue properties. Recently, machine learning has been used to classify burns by combining optical features from multispectral or hyperspectral imaging. Rather than employ models of light propagation to deduce tissue optical properties, we investigated the feasibility of using SFDI reflectance data at multiple spatial frequencies, with a support vector machine (SVM) classifier, to predict severity in a porcine model of graded burns. Calibrated reflectance images were collected using SFDI at eight wavelengths (471 to 851 nm) and five spatial frequencies (0 to 0.2 mm − 1). Three models were built from subsets of this initial dataset. The first subset included data taken at all wavelengths with the planar (0 mm − 1) spatial frequency, the second comprised data at all wavelengths and spatial frequencies, and the third used all collected data at values relative to unburned tissue. These data subsets were used to train and test cubic SVM models, and compared against burn status 28 days after injury. Model accuracy was established through leave-one-out cross-validation testing. The model based on images obtained at all wavelengths and spatial frequencies predicted burn severity at 24 h with 92.5% accuracy. The model composed of all values relative to unburned skin was 94.4% accurate. By comparison, the model that employed only planar illumination was 88.8% accurate. This investigation suggests that the combination of SFDI with machine learning has potential for accurately predicting burn severity.

16 July 2019 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
GKGordon T. Kennedy
Gordon T. Kennedy
RSRandolph Stone
Randolph Stone
AKAndrew C. Kowalczewski
Andrew C. Kowalczewski
RRRebecca A. Rowland
Rebecca A. Rowland
JCJeffrey H. Chen
Jeffrey H. Chen
ADAnthony J. Durkin
Anthony J. Durkin
Annually in the USA, there are ∼500,000 burn wounds that require medical attention and, of these, some 40,000 patients require hospitalization for their burn injuries.1 A large number of these patients will require skin grafts. For deep partial to full thickness burns, the standard of care is surgical debridement of the devitalized burned tissue, through a technique called tangential excision, followed by application of an autologous split-thickness skin graft.2 In this procedure, the patient’s own skin, consisting of the epidermis and a portion of dermis, is taken from a donor site using a dermatome. The autograft may be meshed, allowing it to be expanded to cover a greater surface area. Typically the donor wounds re-epithelialize in 10 to 14 days and the autografted burns will accept a graft by day 5 and become fixed and durable in 10 to 14 days. In many cases, the grafted burn heals with some degree of contraction and scarring, depending on the degree of the meshing, the depth of burn, and the timeliness of accurate burn wound assessment and surgical intervention.3

3 July 2019 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
MTMohammad Torabzadeh
Mohammad Torabzadeh
PSPatrick A. Stockton
Patrick A. Stockton
GKGordon T. Kennedy
Gordon T. Kennedy
RSRolf B. Saager
Rolf B. Saager
ADAnthony J. Durkin
Anthony J. Durkin
BTBruce J. Tromberg
Bruce J. Tromberg
Biomedical hyperspectral imaging (HSI) combines high-resolution spectral and spatial content, in order to characterize tissue structure and composition. Because HSI typically employs hundreds or thousands of optical wavelengths, multiple endogenous and exogenous tissue components with unique spectral signatures can be resolved. Various HSI technical approaches have been developed for biomedical applications—most based on designs that generate reflectance and/or fluorescence maps over a continuous spectral bandwidth.1 – 3 Hyperspectral content can be used in conjunction with computational models of light transport and various statistical methods, such as principal component analysis, to calculate optical and physiological properties for each pixel.4 – 6 However, these methods generally require assumptions or approximations about certain tissue features, such as scattering properties and water concentration.7,8 Unlike temporally or spatially resolved approaches, they do not independently separate and map subsurface tissue absorption and reduced scattering parameters, μa and μs′, respectively, for each wavelength and pixel.9 Changes in each of these parameters occur with spatial and temporal variations in tissue molecular composition and structure. As a result, quantitatively characterizing these light–tissue interactions over a broad spectral range with high temporal resolution can be important in accurately recovering dynamics of multiple endogenous and exogenous tissue chromophores.10,11

5 February 2019 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
RSRolf B. Saager
Rolf B. Saager
RRRebecca A. Rowland
Rebecca A. Rowland
MBMelissa L. Baldado
Melissa L. Baldado
GKGordon T. Kennedy
Gordon T. Kennedy
NBNicole P. Bernal
Nicole P. Bernal
ADAnthony J. Durkin
Anthony J. Durkin
Burn wounds and wound healing invoke several biological processes that may complicate the interpretation of spectral imaging data. Through analysis of spatial frequency domain spectroscopy data (450 to 1000 nm) obtained from longitudinal investigations using a graded porcine burn wound healing model, we have identified features in the absorption spectrum that appear to suggest the presence of hemoglobin breakdown products, e.g., methemoglobin. Our results show that the calculated concentrations of methemoglobin directly correlate with burn severity, 24 h after the injury. In addition, tissue parameters such as oxygenation (StO2) and water fraction may be underestimated by 20% and 78%, respectively, if methemoglobin is not included in the spectral analysis. There are several physiological parameters associated with burn wounds and wound healing that can be detected and quantified optically. Structural changes to tissue from thermal insult (collagen denaturation, protein coagulation, etc.) can be detected by changes in how light scatters through tissue (i.e., reduced scattering coefficient). Similarly, changes in functional characteristics, such as tissue oxygen saturation, blood volume, and water fraction, (edema) can be monitored by how tissue absorbs light (i.e., absorption coefficient).1,2 In the case of thermal burn wounds and its subsequent wound healing response, however, there are biological processes (e.g., extravasation, inflammation, granulation, and tissue remodeling)3,4 that can affect how spectral imaging methods interpret both structural and functional parameters in tissue. With a thermal insult, there can be disruption of the vascular network, leaving blood trapped within the affected tissue. As trapped hemoglobin breaks down, the byproducts (e.g., methemoglobin) could then contribute to the measured spectra.5 This process may have previously uncharacterized consequences for optical imaging methods as it may interfere with standard methods for interpreting and quantifying absorption data in terms of parameters such as tissue oxygen saturation. While multispectral approaches have been applied toward the early detection and triage of burn wounds and shown great potential, these instruments and approaches often use limited spectral sampling and resolution.1,2,6,7 Spatial frequency domain imaging (SFDI) has been of particular interest in this application as it quantifies absorption and scattering optical properties of in-vivo tissue at every wavelength independently using the diffuse reflectance response from tissue as a function of the pattern frequency projected and a scaled Monte Carlo to model photon migration.8 This enables separation of changes in tissue structure from those resulting from changes in absorption characteristics without any additional presumed scattering model or chromophores.2,9 10. 11. 12. – 13 When it comes to determining tissue constituents, many other analysis techniques depend on a priori models that presume all potential sources of optical contrast within tissue in order to interpret measured data. Though blood breakdown products such as methemoglobin are not usually considered in optical device measurements of tissue oxygen saturation, it has already been suggested that they might play a significant role in burn wounds.14,15 Our primary objective is to investigate whether spectral signatures from methemoglobin (MetHb) are present, in vivo, in optical measurements of burn wounds and what influence they may exert in the accurate and reliable determination of other tissue functional parameters. Additionally, we will evaluate how these blood breakdown products might impact the performance of a commercial multispectral imager that has coarse spectral resolution and relatively few illumination wavelengths. This is done as a side-by-side comparison with the high spectral resolution approach using the same set of in vivo burn data as described as follows. In this investigation, spectrally resolved tissue optical properties were calculated using a technique called spatial frequency domain spectroscopy (SFDS).16 Here, the reflectance data were measured by a custom-built, handheld spectral imaging system, described in greater detail elsewhere.17 This device projects broadband (450 to 1000 nm) illumination of sinusoidal intensity and then detects the spatial frequency-dependent responses from tissue along a ∼3-cm line, at ∼1  nm spectral resolution. In this study, five evenly spaced spatial frequencies were employed ranging from 0 to 0.2  mm−1. Three phases (i.e., 0 deg, 120 deg, and 240 deg) of each frequency were projected, as has been our convention, so that the frequency-dependent reflectance can be extracted at each spatial location independent from adjacent measurement locations.8 We have applied this handheld SFDS system in an established porcine burn wound model of graded burn severity.2 In this study, a specialized tool was used to create a series of graded burns on the back of a Yorkshire pig, 3 cm in diameter. The SFDS spectral imager measured the multiply scattered light from both burn region and adjacent tissue with ∼3  nm spectral resolution over several distinct longitudinal time points that allow us to compare preburn, acutely postburn, and at a couple of time points that correspond with those that are indicated as important time points for burn severity assessment (out to 3 days postburn). All experiments followed protocols reviewed and approved by the UC Irvine Institutional Animal Care and Use Committee (IACUC #2015-3154). Tissue absorption coefficient spectra are then extracted from these measurements and subsequently decomposed to identify all physiologic sources of absorption contrast present in the in vivo tissues, including those of hemoglobin breakdown products, over the wavelength range of 450 to 1000 nm. From the spectral components identified by SFDS, we can demonstrate how the presence and dynamics of the methemoglobin in the wound healing process will impact the concentration estimation of other functional tissue parameters if not properly accounted for. Using a validated spectral bandwidth emulation approach, we can transform SFDS data to mimic the same spectral qualities of multispectral imagers within the visible and near-infrared ranges.14 In this investigation, we consider the spectral performance of a commercially available, LED-based SFDI device: the OxImager RS, (Modulated Imaging, Inc.). Here, chromophore concentrations calculated from the emulated spectral data from the commercial instrument will be compared to those determined using the full spectral resolution of SFDS. This particular instrument was selected in this evaluation as it is has been used in several investigations of burn wounds and remains actively engaged in our ongoing studies. The spectral characteristics of this LED-based imager used for this evaluation have been published elsewhere.14 Figure 1 shows the evolution of tissue absorption within the burned tissue over time. Here, the spectra are derived from the average of a ∼1-cm line (∼300  pixels) within the center of the 3-cm wide burn. Spectra recorded at earlier time points are included in visualization of later time points to help illustrate the shifts that occur in relative magnitude and shape of the absorption spectra. In the case of the 10-s burn (superficial), the spectral changes are slight, indicative of minimal tissue damage and wound healing response. There was a greater change in the 20-s burn (superficial partial thickness); however, the spectrum returned to its preburn shape and magnitude by 72 h, potentially indicating a complete recovery. Both 30 and 40 s burns (deep partial and full thickness) not only fail to return to baseline by 72 h, an additional, broad absorption feature becomes readily apparent by 24 h. This feature is not replicated or explained by combinations of common tissue chromophores (i.e., oxy- and deoxyhemoglobin, water, melanin, lipids, etc.). Given the shape and location of absorption bands, this burn-induced spectral feature correlates strongly with hemoglobin breakdown products, e.g., MetHb. To this end, we used the absorption spectrum for pure MetHb from Zijlstra et.al.18 <!-- named anchor --> Fig. 1 Temporal evolution of absorption spectra as a function of burn severity (rows) and over discrete time points (columns). Thick lines are the absorption spectrum at a given time point, thin lines represent the spectra for that specific burn type from previous time points (for reference). Without the inclusion of MetHb in the spectral analysis, errors in the determination of several other tissue parameters will arise, as shown in Fig. 2. This figure depicts the spectral fits to the measured absorption spectra from the 30-s burn case (deep partial thickness burn). Here, the results of two least-squares fits are shown. The first fit result presumes oxy- and deoxyhemoglobin, water, and melanin are the only absorbing constituents present in the tissue volume; the second fit result also includes MetHb in this spectral model. Using the normalized root mean square error as the cost function for a goodness of fit metric, including MetHb maintains a goodness of fit to within 85% of the measured data over all time points, but without its inclusion, the agreement can degrade to ∼56%. <!-- named anchor --> Fig. 2 Measured and fitted tissue absorption spectra for the 30 s (deep partial thickness) burn over time. Solid lines represent the measured absorption spectra. Dashed lines represent the linear least-squares fit produced when only HbO2, Hb, water, and melanin are used as a spectral basis set. Dotted lines represent the fit when pure MetHb is added to the basis set. Inclusion of MetHb in the spectral fitting will not only improve the goodness of fit but also have significant impact on the quantification of other tissue chromophores and physiological parameters. Within the context of the four burn severities investigated here, tissue oxygen saturation, StO2, is underestimated by as much as 20% within the first 3 days postburn and the tissue water fraction, is underestimated by as much as 78% when MetHb is not included in the fitting the measured SFDS absorption spectra. Largely, the magnitude of these underestimation errors directly correlate with increased concentration of MetHb within tissue volumes, hence these estimation errors increase with burn severity (i.e., 30 and 40 s burns), and with time (i.e., 24 and 72 h time points). It is worth noting that even in less severe burns, such as the case of the superficial partial thickness (20 s) burns, StO2 and water fraction may be underestimated by 12% and 8%, respectively, 24 h after the injury. Lastly, we have also determined that even with only eight spectral bands that span both visible and near-infrared wavelength regimes, a multispectral SFDI imager can account for MetHb, producing functional tissue parameters that agree with the high spectral resolution data (SFDS). Through emulating the OxImager’s spectral profile with all the collected SFDS data, we can directly evaluate the impact that a reduced set of spectral bands and resolution may have on the calculation of tissue optical properties. In this case, this particular multispectral imager would determine StO2 within 3.9% and water fraction within 6.9% of the values calculated using all spectral content collected by SFDS. These results include all burn types and time points considered in this initial investigation. While the goodness of fit metric, shown in Fig. 2, demonstrates that incorporating a pure MetHb spectrum in our fitting model significantly reduces residual features between measurement and model and supports the assertions of others,14,15 there are still some spectral regions where fitting is poor. Whereas pure methemoglobin has a distinct feature (shoulder) in its absorption near 630 to 640 nm, the measured data do not indicate any such shoulder, but rather shows a smooth, featureless slope through that spectral range. One possible explanation for this discrepancy is that the additional absorption feature measured in tissue is not pure MetHb, but rather a continuum of transitional heme products that are also evolving over time. As the molecular structure is progressively being altered, absorption bands could shift and/or broaden and thereby result in a measured absorption spectrum that represent the larger, general shape of MetHb, yet wash out the finer, distinct features. Further investigation into this possibility is ongoing. Interestingly, initial attempts in fabricating hemoglobin-based tissue simulating phantoms from freeze-dried bovine hemoglobin have resulted in similar washed out, MetHb-like absorption features.19,20 In addition to the identification of spectral signatures from MetHb present in burn wound tissue and how that may impact reliable assessment of tissue function, quantification of this chromophore may also hold some diagnostic value on its own, as others have suggested.15 Figure 3 shows the changes in calculated MetHb concentrations (plotted in terms of volume fraction) over time for each burn type. While little MetHb was detected within the first hour of the burn, there was a dramatic spread of concentrations at the 24-h time point. Plotting the 24-h concentration values as a function of burn severity showed a surprisingly linear correlation. Since it is drawn from such a small data set, this result is merely anecdotal. However, it may suggest that quantification of MetHb may provide additional and complementary information to assess and characterize burn wound severity. While parameters such as StO2 and water fraction (edema) may indicate the tissues functional response to the injury, MetHb may indicate a measure of the amount of damage. The combination of these parameters may present unique opportunities to advance burn wound assessment toward personalized medicine where it is critical to know not just how much damage has occurred within the wound, but whether the patient has initiated a wound healing response and whether that response will be sufficient to heal the wound on its own. <!-- named anchor --> Fig. 3 Methemoglobin concentration over time. Inset figure shows the positive correlation of the calculated concentration to burn severity (time duration of burn injury) after 24 h. In conclusion, we have demonstrated that additional hemoglobin species will arise in tissue from burn wound injuries and dynamically vary in concentration during the wound healing process. Based on the spectral characterization from in vivo burn wound measurements, these absorption features correlate to hemoglobin breakdown products, e.g., MetHb. Additionally, we have also demonstrated that it is important to include MetHb in any multispectral image analysis in order to produce robust estimates of other tissue parameters, such as StO2 and water fraction. <!-- named anchor --> Disclosures Dr. Durkin has a financial interest in Modulated Imaging, Inc., which developed the Reflect RS™. However, Dr. Durkin does not participate in the management of Modulated Imaging and has not shared these results with that company. Conflicts of interest have been disclosed and carefully managed in accordance with the University of California and NIH policies. The other authors have no financial interests or commercial associations that might pose or create a conflict of interest with the information presented in this article. <!-- named anchor --> Acknowledgments We thankfully recognize support from NIGMS grant R01GM108634-01A which enabled the use of the OxImager RS and collection of porcine data. We also recognize support from the NIH, including NIBIB P41EB015890 (A Biomedical Technology Resource) SFDS device fabrication was facilitated via, a triumvirate grant from the UCI Institute for Clinical and Translational Sciences. The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIGMS, NIBIB, or NIH. In addition, this material is based on technology development supported in part by the Air Force Office of Scientific Research under award number FA9550-17-1-0193. Any opinions, findings, and conclusions or recommendations expressed in this material are those of the authors and do not necessarily reflect the views of the United States Air Force. We also thank the Arnold & Mabel Beckman Foundation. <!-- named anchor --> <!-- named anchor --> References 1. <!-- named anchor --> Nguyen J. Q. et al., “Spatial frequency domain imaging of burn wounds in a preclinical model of graded burn severity,” J. Biomed. Opt., 18 (6), 066010 (2013). https://doi.org/10.1117/1.JBO.18.6.066010 JBOPFO 1083-3668 Google Scholar 2. <!-- named anchor --> Ponticorvo A. et al., “Quantitative assessment of graded burn wounds in a porcine model using spatial frequency domain imaging (SFDI) and laser speckle imaging (LSI),” Biomed. Opt. Express, 5 (10), 3467 –3481 (2014). https://doi.org/10.1364/BOE.5.003467 BOEICL 2156-7085 Google Scholar 3. <!-- named anchor --> Singer A. J., Clark R. A., “Cutaneous wound healing,” N. Engl. J. Med., 341 (10), 738 –746 (1999). https://doi.org/10.1056/NEJM199909023411006 NEJMAG 0028-4793 Google Scholar 4. <!-- named anchor --> Rose L. F. et al., “The burn wound microenvironment,” Adv. Wound Care (New Rochelle), 5 (3), 106 –118 (2016). https://doi.org/10.1089/wound.2014.0536 Google...