Rebecca A. Rowland

Rebecca A. Rowland

Auto-generated profile, based on publicly available information

Rebecca A. Rowland

Beckman Laser Institute and Medical Clinic (United States)

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2016 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
RSRolf B. Saager
Rolf B. Saager
AQAlan Quach
Alan Quach
RRRebecca A. Rowland
Rebecca A. Rowland
MBMelissa L. Baldado
Melissa L. Baldado
ADAnthony J. Durkin
Anthony J. Durkin
We present a method for low-cost fabrication of polydimethylsiloxane (PDMS) tissue simulating phantoms with tunable scattering spectra, spanning visible, and near-infrared regimes. These phantoms use optical polishing agents (aluminum oxide powders) at various grit sizes to approximate in vivo tissue scattering particles across multiple size distributions (range: 17 to 3  μm). This class of tunable scattering phantoms is used to mimic distinct changes in wavelength-dependent scattering properties observed in tissue pathologies such as partial thickness burns. Described by a power-law dependence on wavelength, the scattering magnitude of these phantoms scale linearly with particle concentration over a physiologic range [μs′=(0.5 to 2.0  mm−1)] whereas the scattering spectra, specific to each particle size distribution, correlate to distinct exponential coefficients (range: 0.007 to 0.32). Aluminum oxide powders used in this investigation did not detectably contribute to the absorption properties of these phantoms. The optical properties of these phantoms are verified through inverse adding-doubling methods and the tolerances of this fabrication method are discussed.

10 February 2021 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
TPThinh Phan
Thinh Phan
RRRebecca Rowland
Rebecca Rowland
APAdrien Ponticorvo
Adrien Ponticorvo
BLBinh C. Le
Binh C. Le
RWRobert H. Wilson
Robert H. Wilson
ADAnthony J. Durkin
Anthony J. Durkin
Diffuse optical spectroscopic (DOS) techniques have been widely used to obtain in vivo tissue optical properties.1,2 Using light transport models in the temporal and spatial domains, these techniques can quantify tissue absorption and scattering.3 – 5 Specifically, DOS techniques quantify the wavelength-dependent tissue reduced scattering (μs′) and absorption (μa) coefficients, which can be used to deduce subsurface structural and functional information. Recently, researchers have used μs′ to noninvasively assess wound healing.6 – 8 In a porcine burn model, we previously showed that μs′ may accurately predict burn severity and skin wound healing capabilities.9 – 11 Although these results showed promise for a potential new approach to rapidly assess burn severity and prognosticate wound healing, translating this technique to human subjects necessitates an understanding of baseline μs′ values in human skin. Thus, it is important to document μs′ values of normal skin at commonly used DOS wavelengths (visible- and near-infrared) for various anatomical locations and levels of pigmentation.

1 August 2014 in Journal of Biomedical Optics
Verified
Journal Article
Open access
RWRobert H. Wilson
Robert H. Wilson
KNKyle P. Nadeau
Kyle P. Nadeau
FJFrank B. Jaworski
Frank B. Jaworski
RRRebecca Rowland
Rebecca Rowland
JNJohn Q. Nguyen
John Q. Nguyen
ADAnthony J. Durkin
Anthony J. Durkin
Extending the wavelength range of spatial frequency domain imaging (SFDI) into the short-wave infrared (SWIR) has the potential to provide enhanced sensitivity to chromophores such as water and lipids that have prominent absorption features in the SWIR region. Here, we present, for the first time, a method combining SFDI with unstructured (zero spatial frequency) illumination to extract tissue absorption and scattering properties over a wavelength range (850 to 1800 nm) largely unexplored by previous tissue optics techniques. To obtain images over this wavelength range, we employ a SWIR camera in conjunction with an SFDI system. We use SFDI to obtain in vivo tissue reduced scattering coefficients at the wavelengths from 850 to 1050 nm, and then use unstructured wide-field illumination and an extrapolated power-law fit to this scattering spectrum to extract the absorption spectrum from 850 to 1800 nm. Our proof-of-principle experiment in a rat burn model illustrates that the combination of multispectral SWIR imaging, SFDI, and unstructured illumination can characterize in vivo changes in skin optical properties over a greatly expanded wavelength range. In the rat burn experiment, these changes (relative to normal, unburned skin) included increased absorption and increased scattering amplitude and slope, consistent with changes that we previously reported in the near-infrared using SFDI.

1 April 2020 in Burns Open
Verified
Journal Article
Open access
APAdrien Ponticorvo
Adrien Ponticorvo
RRRebecca Rowland
Rebecca Rowland
MBMelissa Baldado
Melissa Baldado
GKGordon T. Kennedy
Gordon T. Kennedy
AHAnna-Marie Hosking
Anna-Marie Hosking
ADAnthony J. Durkin
Anthony J. Durkin
While visual assessment by a clinician is the standard of care for burn severity evaluations, new technologies at various stages of development are attempting to add objectivity to this practice by quantifying burn severity. Assessment accuracy generally improves after the burn injury has progressed, but early assessments that correctly identify superficial partial and deep partial burns have the potential to lead to more prompt treatments and shorter recovery times. To date, Spatial Frequency Domain Imaging (SFDI) has only been used in animal models of burns, but has shown the potential to categorize burns accurately at earlier time points. Here we examine the potential for SFDI to assess burn severity in clinical patients. We also utilize Laser Speckle Imaging (LSI), an FDA cleared non-invasive imaging technology that typically measures blood perfusion in order to evaluate burns in clinical patients. We present a case series of two patients, both with partial thickness burns of varying severity. Partial thickness burns are often difficult for clinicians to categorize based on visual appearance alone. SFDI and LSI were both performed on each patient at approximately 24 and 72 h after their respective burn incidents. Each technique was able to render spatially resolved information that enabled improved assessment accuracy for each burn. This represents the first publication of SFDI applied to clinical burn patients after being successfully utilized in animal models, and highlights the potential for SFDI as a feasible tool for the timely categorization of burn severity.

27 November 2019 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
RRRebecca Rowland
Rebecca Rowland
APAdrien Ponticorvo
Adrien Ponticorvo
ALAlberto Jarrin Lopez
Alberto Jarrin Lopez
SLShiri Li
Shiri Li
XLXiaodong Li
Xiaodong Li
ADAnthony J. Durkin
Anthony J. Durkin
Renal failure, due to complications such as glomerular disease, diabetes, vascular disease, or hypertension, often necessitates a kidney transplant. In the United States, the number of kidney transplantations makes up the majority of organ transplantation procedures at around 21,000 annually.1 Currently, 74,000 patients are active on the waitlist, 113,000 patients are on the total waitlist, and the number of patients has been increasing by about 8% every year.1 About 32% of patients receive transplants from living donors, but the remaining 68% receive kidneys from deceased donors.2 To facilitate this operation, kidneys from the deceased donor are generally preserved in a cold storage solution during a period called cold ischemic time (CIT).3,4 During the CIT, preserved kidneys are kept at a temperature of 4°C, to decrease the metabolic rate and thereby maintain tissue viability given the lower oxidative damage.5 However, kidney preservation results in renal ischemia and the subsequent generation of reactive oxygen species due to anaerobic glycolysis.6,7 This can cause acute tubular necrosis leading to delayed graft function. It is estimated that as many as 40% of deceased donor kidneys undergo some kind of delayed graft function.8 As a result, patients must undergo dialysis therapy after transplantation, which increases risk for acute rejection of the grafted kidney.9 However, it is difficult to predict if the patient will experience delayed graft function until after transplantation. Explicit criteria for discarding potential donor kidneys are not standardized, which has led to high discard rates within the United States.10 In 2015, almost one-fifth of procured kidneys were discarded.11 The discard rate is higher (42%) in cases of marginal donors, who have increased risk factors such as advanced age, hypertension, or diabetes.12 Evaluation of pretransplant biopsies is time consuming, subject to variable assessment, and is performed in fewer than 20% of standard donor cases and fewer than 80% of marginal donor cases.13 Determining the quality of kidney pretransplant has become increasingly important, as the demand for kidney transplants rises and centers move toward accepting more kidneys from marginal donors.14

27 May 2019 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
RRRebecca A. Rowland
Rebecca A. Rowland
APAdrien Ponticorvo
Adrien Ponticorvo
MBMelissa L. Baldado
Melissa L. Baldado
GKGordon T. Kennedy
Gordon T. Kennedy
DBDavid Burmeister
David Burmeister
ADAnthony J. Durkin
Anthony J. Durkin
Accurate assessment of burn severity is critical for wound care and the course of treatment. Delays in classification translate to delays in burn management, increasing the risk of scarring and infection. To this end, numerous imaging techniques have been used to examine tissue properties to infer burn severity. Spatial frequency-domain imaging (SFDI) has also been used to characterize burns based on the relationships between histologic observations and changes in tissue properties. Recently, machine learning has been used to classify burns by combining optical features from multispectral or hyperspectral imaging. Rather than employ models of light propagation to deduce tissue optical properties, we investigated the feasibility of using SFDI reflectance data at multiple spatial frequencies, with a support vector machine (SVM) classifier, to predict severity in a porcine model of graded burns. Calibrated reflectance images were collected using SFDI at eight wavelengths (471 to 851 nm) and five spatial frequencies (0 to 0.2 mm − 1). Three models were built from subsets of this initial dataset. The first subset included data taken at all wavelengths with the planar (0 mm − 1) spatial frequency, the second comprised data at all wavelengths and spatial frequencies, and the third used all collected data at values relative to unburned tissue. These data subsets were used to train and test cubic SVM models, and compared against burn status 28 days after injury. Model accuracy was established through leave-one-out cross-validation testing. The model based on images obtained at all wavelengths and spatial frequencies predicted burn severity at 24 h with 92.5% accuracy. The model composed of all values relative to unburned skin was 94.4% accurate. By comparison, the model that employed only planar illumination was 88.8% accurate. This investigation suggests that the combination of SFDI with machine learning has potential for accurately predicting burn severity.