Aims Joint infections cause premature implant failure. The avoidance of bacterial colonisation of implant materials by modification of the material surface is therefore the focus of current research. In this in vitro study the complex interaction of periodic structures on PET and titanium surfaces on the adhesion of Staphylococcus aureus is analysed. Methods and Results Using direct laser interference patterning as well as roll‐to‐roll hot embossing methods, structured periodic textures of different spatial distance were produced on surfaces and S. aureus were cultured for 24 hours on these. The amount of adhering bacteria was quantified using fluorescence microscopy and the local adhesion behaviour was investigated using scanning electron microscopy. For PET structures, minimal bacterial adhesion was identified for an aspect ratio of about 0.02. On titanium structures, S. aureus adhesion was significantly decreased for profile heights of < 200 nm. Our results show a significantly decreased bacterial adhesion for structures with an aspect ratio range of 0.02 to 0.05. Conclusions We show that structuring on surfaces can decrease the amount of S. aureus on titanium and PET as common implant materials. Significance and Impact of the Study The study highlights the immense potential of applying specific structures to implant materials to prevent implant colonization with pathogen bacteria.
17 February 2022 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Fretting corrosion is associated with increased risk of premature implant failure. In this complex in vivo corrosion system, the contribution of static crevice corrosion of the joined metal alloys is still unknown. The aim of this study was to develop a methodology for testing crevice corrosion behavior that simulates the physiological conditions of modular taper junctions and to identify critical factors on corrosion susceptibility. Samples of medical grade CoCr28Mo6 cast and wrought alloy, TiAl6V4 wrought alloy and REX 734 stainless steel were prepared metallographically and the microstructure was investigated using scanning electron microscopy (SEM). Crevice formers that mimic typical geometries of taper junctions were developed. Crevice corrosion immersion tests were performed in different physiological fluids (bovine serum or phosphate buffered saline with additives of 30 mM H2O2 at pH = 1) for 4 weeks at 37°C. SEM with energy dispersive X‐ray spectroscopy as well as focused ion beam were used to characterize the surface morphology, investigate present damages and identify the chemical composition of residues. Macroscopic inspection showed increased crevice corrosion susceptibility of TiAl6V4 and REX 734 under severe simulated inflammatory conditions. CoCr28Mo6 cast alloy exhibited degraded areas next to Cr‐ and Mo‐rich precipitations that were located within the opposed crevices. The results indicate that aggressive electrolyte composition and crevice heights of 50–500 μm are critical influencing factors on crevice corrosion of biomedical alloys. Furthermore, manufacturing‐related microstructure of common implant alloys determines the deterioration of corrosion resistance. The developed method should be used to enhance the corrosion resistance of common implant biomaterials by an adapted microstructure.
The rheological properties of synovial fluid (SF) are essential for the friction behavior and wear performance of total joint replacements. Standardized in vitro wear tests for endoprosthesis recommend diluted calf serum, which exhibits substantial different rheological properties compared to SF. Therefore, the in vitro test conditions do not mimic the in vivo conditions. SF samples from osteoarthritis knee patients and patients undergoing knee endoprosthesis revision surgery were compared biochemically and rheologically. The flow properties of SF samples were compared to synthetic fluid constituents, such as bovine serum albumin (BSA) and hyaluronic acid (HA). Interestingly, HA was identified as a significant contributor to shear-thinning. Using the acquired data and mathematical modelling, the flow behavior of human SF was modelled reliably by an adapted adjustment of biorelevant fluid components. Friction tests in a hard/soft bearing (ceramic/UHMWPE) demonstrated that, in contrast to serum, the synthetic model fluids generate a more realistic friction condition. The developed model for an SF mimicking lubricant is recommended for in vitro wear tests of endoprostheses. Furthermore, the results highlight that simulator tests should be performed with a modified lubricant considering an addition of HA for clinically relevant lubrication conditions.
TiAl6V4 wrought alloy is a standard material used for endoprostheses due to its ideal characteristics in terms of osseointegration. However, the insufficient wear and crevice corrosion resistance of TiAl6V4 are limiting factors that can cause clinical problems. Therefore, the objective of this study was to analyze and identify suitable phases and microstructural states of TiAl6V4 alloy with advantageous implant properties by thermal treatments. By varying the temperature and cooling rate, four heat treatment strategies were derived that produced different microstructural states that differed in morphology, arrangement and proportions of phases present. All TiAl6V4 modifications were characterized regarding their microstructure, mechanical, corrosive and tribological properties, as well as cell adhesion. The acicular, martensitic microstructure achieves a significant hardness increase by up to 63% and exhibits improved corrosion and wear resistance compared to the forged condition. Whereas the modified microstructures showed similar electrochemical properties in polarization tests using different electrolytes (PBS with H2O2 and HCl additives), selective α or β phase dissolution occurred under severe inflammatory crevice conditions after four weeks of exposure at 37 °C. The microstructurally selective corrosion processes resemble the damage patterns of retrieved Ti-based implants and provide a better understanding of clinically relevant in vivo crevice corrosion mechanisms. Furthermore, a microstructural effect on cell attachment was determined and is correlated to the size of the vanadium-rich β phase. These key findings highlight the relevance of an adapted processing of TiAl6V4 alloy to increase the longevity of implants.