Louisa O'Neill

Louisa O'Neill


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2023 in JACC: Clinical Electrophysiology
Verified
Journal Article
Closed access
LOLouisa O'Neill
Louisa O'Neill
MHMilad El Haddad
Milad El Haddad
BBBenjamin Berte
Benjamin Berte
RKRichard Kobza
Richard Kobza
GHGabriela Hilfiker
Gabriela Hilfiker
MDMattias Duytschaever
Mattias Duytschaever

29 November 2021 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
KGKris Gillis
Kris Gillis
LOLouisa O'Neill
Louisa O'Neill
JWJean‐Yves Wielandts
Jean‐Yves Wielandts
GHGabriela Hilfiker
Gabriela Hilfiker
AVAlina Vlase
Alina Vlase
JWJean‐Benoît le Polain de Waroux
Jean‐Benoît le Polain de Waroux

20 May 2019 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Open access
PDF file
SWSteven Williams
Steven Williams
LOLouisa O'Neill
Louisa O'Neill
CRCaroline H Roney
Caroline H Roney
JJJusto Julia
Justo Julia
AMAndreas Metzner
Andreas Metzner
MOMark O'Neill
Mark O'Neill
Background: The multiple wavelets and functional re‐entry hypotheses are mechanistic theories to explain atrial fibrillation (AF). If valid, a chamber's ability to support AF should depend upon the left atrial size, conduction velocity (CV), and refractoriness. Measurement of these parameters could provide a new therapeutic target for AF. We investigated the relationship between left atrial effective conducting size (LAECS), a function of area, CV and refractoriness, and AF vulnerability in patients undergoing AF ablation.Methods and Results: Activation mapping was performed in patients with paroxysmal (n = 21) and persistent AF (n = 18) undergoing pulmonary vein isolation. Parameters used for calculating LAECS were: (a) left atrial body area (A); (b) effective refractory period (ERP); and (c) total activation time (T). Global CV was estimated as . Effective atrial conducting size was calculated as . Post ablation, AF inducibility testing was performed. The critical LAECS required for multiple wavelet termination was determined from computational modeling. LAECS was greater in patients with persistent vs paroxysmal AF (4.4 ± 2.0 cm vs 3.2 ± 1.4 cm; P = .049). AF was inducible in 14/39 patients. LAECS was greater in AF‐inducible patients (4.4 ± 1.8 cm vs 3.3 ± 1.7 cm; P = .035, respectively). The difference in LAECS between inducible and noninducible patients was significant in patients with persistent (P = .0046) but not paroxysmal AF (P = .6359). Computational modeling confirmed that LAECS > 4 cm was required for continuation of AF.Conclusions: LAECS measured post ablation was associated with AF inducibility in patients with persistent, but not paroxysmal AF. These data support a role for this method in electrical substrate assessment in AF patients.

26 December 2017 in EP Europace
Verified
Journal Article
Open access
PDF file
RMRahul K Mukherjee
Rahul K Mukherjee
SRSébastien Roujol
Sébastien Roujol
HCHenry Chubb
Henry Chubb
JHJames Harrison
James Harrison
SWSteven Williams
Steven Williams
RRReza Razavi
Reza Razavi
Magnetic resonance imaging (MRI) is the gold standard for defining myocardial substrate in 3D and can be used to guide ventricular tachycardia ablation. We describe the feasibility of using a prototype magnetic resonance-guided electrophysiology (MR-EP) system in a pre-clinical model to perform real-time MRI-guided epicardial mapping, ablation, and lesion imaging with active catheter tracking. Experiments were performed in vivo in pigs (n = 6) using an MR-EP guidance system research prototype (Siemens Healthcare) with an irrigated ablation catheter (Vision-MR, Imricor) and a dedicated electrophysiology recording system (Advantage-MR, Imricor). Following epicardial access, local activation and voltage maps were acquired, and targeted radiofrequency (RF) ablation lesions were delivered. Ablation lesions were visualized in real time during RF delivery using MR-thermometry and dosimetry. Hyper-acute and acute assessment of ablation lesions was also performed using native T1 mapping and late-gadolinium enhancement (LGE), respectively. High-quality epicardial bipolar electrograms were recorded with a signal-to-noise ratio of greater than 10:1 for a signal of 1.5 mV. During epicardial ablation, localized temperature elevation could be visualized with a maximum temperature rise of 35 °C within 2 mm of the catheter tip relative to remote myocardium. Decreased native T1 times were observed (882 ± 107 ms) in the lesion core 3–5 min after lesion delivery and relative location of lesions matched well to LGE. There was a good correlation between ablation lesion site on the iCMR platform and autopsy. The MR-EP system was able to successfully acquire epicardial voltage and activation maps in swine, deliver, and visualize ablation lesions, demonstrating feasibility for intraprocedural guidance and real-time assessment of ablation injury.

7 December 2022 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
LOLouisa O'Neill
Louisa O'Neill
BBBenjamin De Becker
Benjamin De Becker
MSMaarten De Smet
Maarten De Smet
JWJean-Benoit Le Polain De Waroux
Jean-Benoit Le Polain De Waroux
RTRene Tavernier
Rene Tavernier
SKSebastien Knecht
Sebastien Knecht
Recurrent atrial tachycardia (AT) is a common phenomenon after catheter ablation for AF, particularly in the setting of additional substrate ablation, with many studies demonstrating gap-related macro re-entrant AT (predominantly mitral and roof dependent) to be the dominant mechanism. Although multiple inducible ATs after ablation of the clinical AT are commonly described at repeat procedures, the optimal ablation strategy, and procedural endpoints are unclear in this setting. A recent randomized study addressing the question of non-inducibility as a procedural endpoint demonstrated no additional benefits to the ablation of all induced, non-clinical ATs, but it was limited by small numbers and high rates of non-inducibility. Nevertheless, once ablation of the clinical AT has been successfully performed, ensuring durable linear block and PV isolation may be sufficient for the prevention of further AT. Durable linear block, particularly at the mitral isthmus, is difficult to achieve but may be facilitated by the real-time evaluation of lesion quality and contiguity and the novel technique of vein of Marshall ethanol infusion. Large-scale, randomized trials are needed, nonetheless, to fully assess the optimal ablation strategy in the setting of recurrent AT post-AF ablation.

8 September 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
LOLouisa O'Neill
Louisa O'Neill
JWJean-Yves Wielandts
Jean-Yves Wielandts
KGKris Gillis
Kris Gillis
GHGabriela Hilfiker
Gabriela Hilfiker
JWJean-Benoit Le Polain De Waroux
Jean-Benoit Le Polain De Waroux
SKSebastien Knecht
Sebastien Knecht
Atrial fibrillation (AF) is the most common cardiac arrhythmia worldwide and represents a heterogeneous disorder with a complex pathological basis. While significant technological advances have taken place over the last decade in the field of catheter ablation of AF, response to ablation varies and long-term success rates in those with persistent AF remain modest. Mechanistic studies have highlighted potentially different sustaining factors for AF in the persistent AF population with substrate-driven focal and re-entrant sources in the body of the atria identified on invasive and non-invasive mapping studies. Translation to clinical practice, however, remains challenging and the application of such mapping techniques to clinical ablation has yet to demonstrate a significant benefit beyond pulmonary vein isolation (PVI) alone in the persistent AF cohort. Recent advances in catheter and ablation technology have centered on improving the durability of ablation lesions at index procedure and although encouraging results have been demonstrated with early studies, large-scale trials are awaited. Further meaningful improvement in clinical outcomes in the persistent AF population requires ongoing advancement in the understanding of AF mechanisms, coupled with continuing progress in catheter technology capable of delivering durable transmural lesions.