Laboratory of Advanced Biotechnologies for Health Assessment, Department of Electrical Engineering and Computer Science, Lassonde School of Engineering, York University, Toronto, ON, Canada
Dr. Razieh Salahandish
Laboratory of Advanced Biotechnologies for Health Assessment, Department of Electrical Engineering and Computer Science, Lassonde School of Engineering, York University, Toronto, ON, Canada
Early‐stage disease detection, particularly in P oint‐ O f‐ C are ( POC ) wearable formats, assumes pivotal role in advancing healthcare services and precision‐medicine. Public benefits of early detection extend beyond cost‐effectively promoting healthcare outcomes, to also include reducing the risk of comorbid diseases. Technological advancements enabling POC biomarker recognition empower discovery of new markers for various health conditions. Integration of POC wearables for biomarker detection with intelligent frameworks represents ground‐breaking innovations enabling automation of operations, conducting advanced large‐scale data analysis, generating predictive models, and facilitating remote and guided clinical decision‐making. These advancements substantially alleviate socioeconomic burdens, creating a paradigm shift in diagnostics, and revolutionizing medical assessments and technology development. This review explores critical topics and recent progress in development of 1) POC systems and wearable solutions for early disease detection and physiological monitoring, as well as 2) discussing current trends in adoption of smart technologies within clinical settings and in developing biological assays, and ultimately 3) exploring utilities of POC systems and smart platforms for biomarker discovery. Additionally, the review explores technology translation from research labs to broader applications. It also addresses associated risks, biases, and challenges of widespread A rtificial I ntelligence ( AI ) integration in diagnostics systems, while systematically outlining potential prospects, current challenges, and opportunities.
Stress affects cognition, behavior, and physiology, leading to lasting physical and mental illness. The ability to detect and measure stress, however, is poor. Increased circulating cortisol during stress is mirrored by cortisol release from sweat glands, providing an opportunity to use it as an external biomarker for monitoring internal emotional state. Despite the attempts at using wearable sensors for monitoring sweat cortisol, there is a lack of reliable wearable sweat collection devices that preserve the concentration and integrity of sweat biomolecules corresponding to stress levels. Here, a flexible, self‐powered, evaporation‐free, bubble‐free, surfactant‐free, and scalable capillary microfluidic device, MicroSweat, is fabricated to reliably collect human sweat from different body locations. Cortisol levels are detected corresponding to severe stress ranging from 25 to 125 ng mL−1 averaged across multiple body regions and 100–1000 ng mL−1 from the axilla. A positive nonlinear correlation exists between cortisol concentration and stress levels quantified using the perceived stress scale (PSS). Moreover, owing to the sweat variation in response to environmental effects and physiological differences, the longitudinal and personalized profile of sweat cortisol is acquired, for the first time, for various body locations. The obtained sweat cortisol data is crucial for analyzing human stress in personalized and clinical healthcare sectors.
The simultaneous identification of drugs has considerable difficulties due to the intricate interplay of analytes and the interference present in biological matrices. In this study, we introduce an innovative electrochemical sensor that overcomes these hurdles, enabling the precise and simultaneous determination of morphine (MOR), methadone (MET), and uric acid (UA) in urine samples. The sensor harnesses the strategically adapted carbon nanotubes (CNT) modified with graphitic carbon nitride (g-C3N4) nanosheets to ensure exceptional precision and sensitivity for the targeted analytes. Through systematic optimization of pivotal parameters, we attained accurate and quantitative measurements of the analytes within intricate matrices employing the fast Fourier transform (FFT) voltammetry technique. The sensor’s performance was validated using 17 training and 12 test solutions, employing the widely acclaimed machine learning method, partial least squares (PLS), for predictive modeling. The root mean square error of cross-validation (RMSECV) values for morphine, methadone, and uric acid were significantly low, measuring 0.1827 µM, 0.1951 µM, and 0.1584 µM, respectively, with corresponding root mean square error of prediction (RMSEP) values of 0.1925 µM, 0.2035 µM, and 0.1659 µM. These results showcased the robust resiliency and reliability of our predictive model. Our sensor’s efficacy in real urine samples was demonstrated by the narrow range of relative standard deviation (RSD) values, ranging from 3.71 to 5.26%, and recovery percentages from 96 to 106%. This performance underscores the potential of the sensor for practical and clinical applications, offering precise measurements even in complex and variable biological matrices. The successful integration of g-C3N4-CNT nanocomposites and the robust PLS method has driven the evolution of sophisticated electrochemical sensors, initiating a transformative era in drug analysis.
The exploration of the chiral configurations of enantiomers represents a highly intriguing realm of scientific inquiry due to the distinct roles played by each enantiomer (D and L) in chemical reactions and their practical utilities. This study introduces a pioneering analytical methodology, termed fast Fourier transform capacitance voltammetry (FFT-CPV), in conjunction with principal component analysis (PCA), for the identification and quantification of the chiral forms of tartaric acid (TA), serving as a representative model system for materials exhibiting pronounced chiral characteristics. The proposed methodology relies on the principle of chirality, wherein the capacitance signal generated by the adsorption of D-TA and L-TA onto the surface of a platinum electrode (Pt-electrode) in an acidic solution is harnessed. The capacitance voltammograms were meticulously recorded under optimized experimental conditions. To compile the final dataset for the analyte, the average of the FFT capacitance voltammograms of the acidic solution (without the presence of the analyte) was subtracted from those containing the analyte. A distinct arrangement was obtained by employing PCA as a linear data transformation method, representing D-TA and L-TA in a two/three-dimensional space. The outcomes of the study reveal the successful detection of the two chiral forms of TA with a considerable degree of precision and reproducibility. Moreover, the proposed method facilitated the establishment of two linear response ranges for the concentration values of each enantiomer, spanning from 1 to 20 µM, and 50 to 500 µM. The respective detection limits were also determined to be 0.4 µM for L-TA and 1.3 µM for D-TA. These findings underscore the satisfactory sensitivity and efficiency of the proposed method in both qualitative and quantitative assessments of the chiral forms of TA.
Current laboratory diagnostic approaches for virus detection give reliable results, but they require a lengthy procedure, trained personnel, and expensive equipment and reagents; hence, they are not a suitable choice for home monitoring purposes. This paper addresses this challenge by developing a portable impedimetric biosensing system for the identification of COVID-19 patients. This sensing system has two main parts: a throwaway two-working electrode (2-WE) strip and a novel read-out circuit, specifically designed for simultaneous signal acquisition from both working electrodes. Highly reliable electrochemical signal tracking from multiplex immunosensors provides a potential for flexible and portable multi-biomarker detection. The electrodes’ surfaces were functionalized with SARS-CoV-2 Nucleocapsid Antibody enabling the selective detection of Nucleocapsid protein (N-protein) along with self-validation in the clinical nasopharyngeal swab specimens. The proposed programmable highly sensitive impedance read-out system allows for a wide dynamic detection range, which makes the sensor capable of detecting N-protein concentrations between 0.116 and 10,000 pg/mL. This lightweight and economical read-out arrangement is an ideal prospect for being mass-produced, especially during urgent pandemic situations. Also, such an impedimetric sensing platform has the potential to be redesigned for targeting not only other infectious diseases but also other critical disorders.