Since students and teachers spend much of their time in educational buildings, it is critical to provide good levels of indoor environmental quality (IEQ). The current COVID-19 pandemic has shown that maintaining a good indoor air quality level is an effective measure to control the transmission of the SARS-CoV-2 virus. This study used sensors to monitor key IEQ factors and assess several natural ventilation scenarios in a classroom of the University of Granada. Subsequently, the IEQ factors (temperature, relative humidity, CO2 concentration, acoustic environment, and air velocity) were evaluated for the selected ventilation scenarios in the occupied classroom, and the field monitoring was carried out in two different assessment periods, winter and summer. The obtained results show that the CO2 concentration levels were well below the recommended limits. However, the maintenance of the recommended thermal and acoustic IEQ factors was significantly affected by the natural ventilation strategies (temperature and relative humidity values were very close to the outside values, and the background sound pressure level was over 35 dBA during the entire assessment). The proper measurements and careful selection of the appropriate ventilation scenarios become of utmost importance to ensure that the ventilation rates required by the health authorities are achieved.
The construction and transport sectors are the industries with the highest proportions of workers exposed to vibrations in the European Union. Heavy equipment vehicle (HEV) drivers often perform operations on different uneven surfaces and are exposed to whole body vibration (WBV) on a daily basis. Recently, a new version of ISO 2631-5 was published. However, since this new method required as input the individual exposure profile and the acceleration signals recorded on more surfaces, limited studies have been carried out to evaluate HEV operations according to this standard. The objectives of this study were to assess the WBV exposure using the methods defined in ISO 2631-1:1997 and ISO 2631-5:2018 and to compare the obtained health risk assessments between drivers with different anthropometric characteristics. For this purpose, two drivers were selected and a field measurement campaign was conducted. Regarding short-term assessment, results showed that VDV was the most restrictive method with exposure levels above the exposure action limit value, while indicated that the same exposures were safe for the worker. With respect to long-term assessment, Risk Factor RA showed that the driver with the highest body mass index was the only one who exceeded the low probability limit of adverse health effects.
The pandemic caused by COVID-19 has highlighted the need to ensure good indoor air quality. Public buildings (educational buildings in particular) have come under the spotlight because students, teachers and staff spend long periods of the day indoors. This study presents a measurement campaign for the assessment of ventilation rate (VR) and ventilation strategies in educational buildings in Southwestern Europe, Portugal and Spain. A representative sample of the teaching spaces of the Azurém Campus (Guimarães, Portugal) and the Fuentenueva Campus (Granada, Spain) have been analyzed. Natural ventilation is the predominant ventilation strategy in these spaces, being the most common strategy in educational buildings in Europe. VR was estimated under different configurations, using the CO2 decay method. Subsequently, the CO2 concentration was estimated according to occupancy and the probability of infection risk was calculated using the Wells-Riley equation. The obtained VR varied between 2.9 and 20.1 air change per hour (ACH) for natural cross ventilation, 2.0 to 5.1 ACH for single-sided ventilation and 1.8 to 3.5 for mechanically ventilated classrooms. Large differences in CO2 concentrations were verified, depending on the analyzed ventilation strategy, ranging from 475 to 3903 ppm for the different scenarios. However, the probability of risk was less than 1% in almost all of the classrooms analyzed. The results obtained from the measurement campaign showed that the selection of an appropriate ventilation strategy can provide sufficient air renewal and maintain a low risk of infection. Ventilation strategies need to be reconsidered as a consequence of the health emergency arising from the COVID-19 pandemic.
Managing indoor environmental quality (IEQ) is a challenge in educational buildings in the wake of the COVID-19 pandemic. Adequate indoor air quality is essential to ensure that indoor spaces are safe for students and teachers. In fact, poor IEQ can affect academic performance and student comfort. This study proposes a framework for integrating occupants’ feedback into the building information modelling (BIM) methodology to assess indoor environmental conditions (thermal, acoustic and lighting) and the individual airborne virus transmission risk during teaching activities. The information contained in the parametric 3D BIM model and the algorithmic environment of Dynamo were used to develop the framework. The IEQ evaluation is based on sensor monitoring and a daily schedule, so the results show real problems of occupants’ dissatisfaction. The output of the framework shows in which range the indoor environmental variables were (optimal, acceptable and unacceptable) and the probability of infection during each lecture class (whether or not 1% is exceeded). A case study was proposed to illustrate its application and validate it. The outcomes provide key information to support the decision-making process for managing IEQ and controlling individual airborne virus transmission risks. Long-term application could provide data that support the management of ventilation strategies and protocol redesign.
Indoor environmental conditions can significantly affect occupants’ health and comfort. These conditions are especially important in educational buildings, where students, teachers and staff spend long periods of the day and are vulnerable to these factors. Recently, indoor air quality has been a focus of attention to ensure that disease transmission in these spaces is minimised. In order to increase the knowledge in this field, experimental tests have been carried out to characterise the impact of natural ventilation strategies on indoor air quality and the acoustic environment. This study has evaluated three ventilation scenarios in four different classrooms in buildings of the University of Granada, considering different window and door opening configurations. Ventilation rates were estimated using the CO2 Decay Method, and background noise recordings were made in each classroom for acoustic tests. Results show that specific natural ventilation strategies have a relevant impact that is worth considering on the background noise in indoor spaces. In this sense ventilation rates provided by the different configurations varied between 3.7 and 39.8 air changes per hour (ACH) and the acoustic tests show a background noise ranging from 43 to 54 dBA in these scenarios. Consequently, managers and teachers should take into account not only the ACH, but also other collateral impacts on the indoor environmental conditions such as the thermal comfort or the acoustic environment.