Background: The accuracy of the remote dielectric sensing (ReDSTM) system, which is a noninvasive electromagnetic-based technology to quantify lung fluid levels, particularly among those with small body size, remains uncertain. Methods: Hospitalized patients with and without heart failure underwent assessment of lung fluid levels with ReDS and successive chest computed tomography imaging. We performed a correlation analysis of the ReDS measurement, representing lung fluid levels, and computed tomography-derived high attenuation area percentage, which also provides a spatial quantification of lung fluid level. Results: A total of 46 patients (median 76 years old, 28 men), including 28 patients with heart failure, were included. The median ReDS value was 28% (interquartile: 23%, 33%), and the median percentage of high attenuation area was 21.6% (14.4%, 28.5%). ReDS values and percentage of high attenuation area were moderately correlated (r = 0.65, p < 0.001), irrespective of the existence of heart failure. ReDS value independently predicted the percentage of high attenuation area seen on computed tomography (p < 0.001). Conclusions: The ReDS system may be a promising, noninvasive tool to quantify fluid lung levels, as validated by comparison with chest computed tomography imaging. Further studies are warranted to validate the utility and applicability of this technology to a variety of clinical scenarios.
Background: Remote dielectric sensing (ReDS™) is an electromagnetic-based technology used to noninvasively measure lung fluid levels. The association between ReDS values and invasively measured hemodynamics, particularly among those with small physics, remains unknown. Methods: Consecutive patients with chronic heart failure who were admitted to our institute and underwent invasive right heart catheterization as well as simultaneous ReDS measurement at clinically stable conditions between September and November 2021 were prospectively included. The colinearity between ReDS values and pulmonary capillary wedge pressure was studied. Results: In total, 30 patients (median 79 (73, 84) years old, 13 men) were included. Median ReDS value was 26% (22%, 28%). ReDS values had a moderate collinearity with pulmonary capillary wedge pressure (r = 0.698, p < 0.001), even among those with a body height < 155 cm. ReDS values with a cutoff of 28% predicted a pulmonary capillary wedge pressure > 15 mmHg with sensitivity 0.70 and specificity 0.75. Conclusions: An electromagnetic-based engineering ReDS might be a potential tool to estimate cardiac pressure in patients with heart failure, including those with small physics.
1 April 2019 in American Journal of Physiology-Heart and Circulatory Physiology
Although increased levels of reactive oxygen species (ROS) are involved in the pathogenesis of cardiovascular diseases, the importance of physiological ROS has also been emerging. We have previously demonstrated that endothelium-derived H2O2 is an endothelium-dependent hyperpolarization (EDH) factor and that loss of endothelial caveolin-1 reduces EDH/H2O2 in the microcirculation. Caveolin-1 (Cav-1) is a scaffolding/regulatory protein that interacts with diverse signaling pathways, including angiogenesis. However, it remains unclear whether endothelial Cav-1 plays a role in ischemic angiogenesis by modulating EDH/H2O2. In the present study, we thus addressed this issue in a mouse model of hindlimb ischemia using male endothelium-specific Cav-1 (eCav-1) knockout (KO) mice. In isometric tension experiments with femoral arteries from eCav-1-KO mice, reduced EDH-mediated relaxations to acetylcholine and desensitization of sodium nitroprusside-mediated endothelium-independent relaxations were noted ( n = 4~6). An ex vivo aortic ring assay also showed that the extent of microvessel sprouting was significantly reduced in eCav-1-KO mice compared with wild-type (WT) littermates ( n = 12 each). Blood flow recovery at 4 wk assessed with a laser speckle flowmeter after femoral artery ligation was significantly impaired in eCav-1-KO mice compared with WT littermates ( n = 10 each) and was associated with reduced capillary density and muscle fibrosis in the legs ( n = 6 each). Importantly, posttranslational protein modifications by reactive nitrogen species and ROS, as evaluated by thiol glutathione adducts and nitrotyrosine, respectively, were both increased in eCav-1-KO mice ( n = 6~7 each). These results indicate that endothelial Cav-1 plays an important role in EDH-mediated vasodilatation and ischemic angiogenesis through posttranslational protein modifications by nitrooxidative stress in mice in vivo. NEW & NOTEWORTHY Although increased levels of reactive oxygen species (ROS) are involved in the pathogenesis of cardiovascular diseases, the importance of physiological ROS has also been emerging. The present study provides a line of novel evidence that endothelial caveolin-1 plays important roles in endothelium-dependent hyperpolarization and ischemic angiogenesis in hindlimb ischemia in mice through posttranslational protein modifications by reactive nitrogen species and ROS in mice in vivo.
18 August 2025 in Journal of the American Heart Association
Background: The impact of peridevice leak (PDL) at device implantation on clinical outcomes after percutaneous left atrial appendage closure (LAAC) is unknown. This study aimed to investigate the association between PDL and clinical outcomes after LAAC. Methods: Using data from the OCEAN‐LAAC (Optimized Catheter Valvular Intervention‐Left Atrial Appendage Closure) Japanese multicenter registry, we examined 1397 patients who underwent LAAC between September 2019 and December 2022. The primary outcome was transient ischemic attack, ischemic stroke, or systemic embolism within 2 years of LAAC. Clinical outcomes were compared between patients with and without PDL at device implantation using Fine and Gray multivariable regression analyses and propensity score matching. Additional analyses were performed by categorizing PDL into 2 groups: ≤3 mm and >3 mm but ≤5 mm. Results: Of 1397 patients who underwent LAAC, 84 (6.0%) had PDL, of whom 73 (86.9%) had ≤3 mm PDL. Patients with PDL had a larger left atrium and higher CHADS2 scores than those without PDL. Multivariable analyses showed that PDL was significantly associated with a higher risk of transient ischemic attack, ischemic stroke, or systemic embolism (adjusted subdistribution hazard ratio [sHR], 4.25 [95% CI, 1.91–9.44]; P <0.001). Even PDL ≤3 mm was independently associated with an increased risk compared with no PDL (adjusted sHR, 3.53 [95% CI, 1.37–9.04]; P =0.016). Propensity score matching analyses revealed consistent findings. Conclusions: PDL was associated with a higher risk of transient ischemic attack, ischemic stroke, or systemic embolism, even PDL ≤3 mm. Therefore, it may be necessary to aim for no PDL as much as possible.
There is a consensus that overactivation of the cardiac sympathetic nervous system (CSN) proportionately increases the severity of heart failure and is accompanied by worse prognosis. Because it is unknown whether patients with aortic valve stenosis (AS) have similar CSN activation, we investigated the effect of transcatheter aortic valve implantation (TAVI).Methods and Results:We enrolled 31 consecutive patients with AS treated by TAVI. 123I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy was performed at baseline and at 2 weeks after TAVI. At baseline, the early heart-mediastinum ratio (H/M) was within normal limits (3.0±0.5), but the delayed H/M was low (2.6±0.6) and the washout rate (WR) was high (34±13%). WR negatively correlated with aortic valve area (r=-0.389, P<0.01) and cardiac output (r=-0.595, P<0.01) and positively correlated with norepinephrine (r=0.519, P<0.01) and log NT-proBNP level (r=0.613, P<0.01). After TAVI, there were significant decreases in the norepinephrine level (366±179 ng/mL vs. 276±125 ng/mL, P<0.01) and WR (34±13 vs. 26±11%, P<0.01). The WR of MIBG was a useful marker of CSN activity and severity of AS. Immediate improvement of CSN activity after TAVI implied that AS hemodynamics per se enhanced CSN.
7 September 2022 in European Heart Journal - Case Reports
Background: Secondary mitral regurgitation (SMR) is a major comorbidity in patients with heart failure with reduced ejection fraction (HFrEF). Transcatheter edge-to-edge repair (TEER) using the MitraClip™ system is a promising tool for selected patients with SMR and HFrEF. Durable success using this system in patients who have advanced heart failure and unsuitable anatomy remains a clinical challenge. Case summary: Three patients aged 67–72 years with HFrEF on inotropic support successfully underwent Impella®-assisted TEER at our centre. Following the procedure, two patients were able to be weaned off inotropic support and were discharged, while one patient expired during the index hospitalization. Discussion: Impella®-assisted TEER may be a feasible strategy for patients with SMR and HFrEF with unstable haemodynamics particularly when cardiac replacement therapy is not applicable.