Hiroshi Ueno

Dr. Hiroshi Ueno

Toyama University Hospital
orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2023 in Journal of the American Heart Association
Verified
Journal Article
Open access
SKShunsuke Kubo
Shunsuke Kubo
MYMasanori Yamamoto
Masanori Yamamoto
MSMike Saji
Mike Saji
MAMasahiko Asami
Masahiko Asami
YEYusuke Enta
Yusuke Enta
KHKentaro Hayashida
Kentaro Hayashida
Background: Limited data are available about clinical outcomes and residual mitral regurgitation (MR) after transcatheter edge‐to‐edge repair in the large Asian‐Pacific cohort. Methods and Results: From the Optimized Catheter Valvular Intervention (OCEAN‐Mitral) registry, a total of 2150 patients (primary cause of 34.6%) undergoing transcatheter edge‐to‐edge repair were analyzed and classified into 3 groups according to the residual MR severity at discharge: MR 0+/1+, 2+, and 3+/4+. The mortality and heart failure hospitalization rates at 1 year were 12.3% and 15.0%, respectively. Both MR and symptomatic improvement were sustained at 1 year with MR ≤2+ in 94.1% of patients and New York Heart Association functional class I/II in 95.0% of patients. Compared with residual MR 0+/1+ (20.4%) at discharge, both residual MR 2+ (30.2%; P < 0.001) and 3+/4+ (32.4%; P = 0.007) were associated with the higher incidence of death or heart failure hospitalization (adjusted hazard ratio [HR], 1.59; P < 0.001, and adjusted HR, 1.73; P = 0.008). New York Heart Association class III/IV at 1 year was more common in the MR 3+/4+ group (20.0%) than in the MR 0+/1+ (4.6%; P < 0.001) and MR 2+ (6.4%; P < 0.001) groups, and the proportion of New York Heart Association class I is significantly higher in the MR 1+ group (57.8%) than in the MR 2+ group (48.3%; P = 0.02). Conclusions: The OCEAN‐Mitral registry demonstrated favorable clinical outcomes and sustained MR reduction at 1 year in patients undergoing transcatheter edge‐to‐edge repair. Both residual MR 2+ and 3+/4+ after transcatheter edge‐to‐edge repair at discharge were associated with worse clinical outcomes compared with residual MR 0+/1+. Registration Information: https://upload.umin.ac.jp . Identifier: UMIN000023653.

29 August 2023 in JACC: Asia
Verified
Journal Article
Open access
MSMike Saji
Mike Saji
MYMasanori Yamamoto
Masanori Yamamoto
SKShunsuke Kubo
Shunsuke Kubo
MAMasahiko Asami
Masahiko Asami
YEYusuke Enta
Yusuke Enta
KHKentaro Hayashida
Kentaro Hayashida
Transcatheter edge-to-edge repair (TEER) is a less invasive treatment for patients with mitral regurgitation (MR). Limited safety and efficacy data of TEER with MitraClip, including the fourth-generation (G4) system, in a large cohort, are available. This study aimed to summarize the initial experience of the TEER system in patients with MR from a large registry in Japan. The OCEAN (Optimized CathEter vAlvular iNtervention)-Mitral Registry is an ongoing, prospective, investigator-initiated, multicenter, observational registry for patients with primary and secondary MR undergoing transcatheter mitral valve therapies. A total of 21 centers participated in the registry. Patients undergoing TEER were enrolled, and their characteristics, procedural details, and clinical outcomes were recorded. In total, 2,150 patients including 1,605 patients (75.0%) with secondary MR, were enrolled between April 2018 and June 2021. The median age was 80 years, and 43.7% were women. The median device and fluoroscopy times were 60 and 26 minutes, respectively. Those with the G4 system (618/2,150 [28.7%]) were significantly shorter than those with the second generation (G2) system (1,532/2,150 [71.3%]). Overall, 94.6% met acute procedural success without significant differences between the 2 systems (G2 94.7% vs G4 94.6%; P = 0.961). The OCEAN-Mitral registry has demonstrated the short-term outcomes of TEER systems, including the G4 system, in symptomatic patients with primary and secondary MR. The acute procedural success rate in the G2 system was excellent, and that in the G4 system was expected to improve with the multidisciplinary heart valve team approach. (Japanese Registry study of valvular heart diseases treatment and prognosis; UMIN000023653)

23 February 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Teruhiko ImamuraTeruhiko Imamura
Teruhiko Imamura
MHMasakazu Hori
Masakazu Hori
YUYohei Ueno
Yohei Ueno
NNNikhil Narang
Nikhil Narang
HOHiroshi Onoda
Hiroshi Onoda
KKKoichiro Kinugawa
Koichiro Kinugawa
Background: Remote dielectric sensing (ReDS™) is an electromagnetic-based technology used to noninvasively measure lung fluid levels. The association between ReDS values and invasively measured hemodynamics, particularly among those with small physics, remains unknown. Methods: Consecutive patients with chronic heart failure who were admitted to our institute and underwent invasive right heart catheterization as well as simultaneous ReDS measurement at clinically stable conditions between September and November 2021 were prospectively included. The colinearity between ReDS values and pulmonary capillary wedge pressure was studied. Results: In total, 30 patients (median 79 (73, 84) years old, 13 men) were included. Median ReDS value was 26% (22%, 28%). ReDS values had a moderate collinearity with pulmonary capillary wedge pressure (r = 0.698, p < 0.001), even among those with a body height < 155 cm. ReDS values with a cutoff of 28% predicted a pulmonary capillary wedge pressure > 15 mmHg with sensitivity 0.70 and specificity 0.75. Conclusions: An electromagnetic-based engineering ReDS might be a potential tool to estimate cardiac pressure in patients with heart failure, including those with small physics.

29 December 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Teruhiko ImamuraTeruhiko Imamura
Teruhiko Imamura
WGWataru Gonoi
Wataru Gonoi
MHMasakazu Hori
Masakazu Hori
YUYohei Ueno
Yohei Ueno
NNNikhil Narang
Nikhil Narang
KKKoichiro Kinugawa
Koichiro Kinugawa
Background: The accuracy of the remote dielectric sensing (ReDSTM) system, which is a noninvasive electromagnetic-based technology to quantify lung fluid levels, particularly among those with small body size, remains uncertain. Methods: Hospitalized patients with and without heart failure underwent assessment of lung fluid levels with ReDS and successive chest computed tomography imaging. We performed a correlation analysis of the ReDS measurement, representing lung fluid levels, and computed tomography-derived high attenuation area percentage, which also provides a spatial quantification of lung fluid level. Results: A total of 46 patients (median 76 years old, 28 men), including 28 patients with heart failure, were included. The median ReDS value was 28% (interquartile: 23%, 33%), and the median percentage of high attenuation area was 21.6% (14.4%, 28.5%). ReDS values and percentage of high attenuation area were moderately correlated (r = 0.65, p < 0.001), irrespective of the existence of heart failure. ReDS value independently predicted the percentage of high attenuation area seen on computed tomography (p < 0.001). Conclusions: The ReDS system may be a promising, noninvasive tool to quantify fluid lung levels, as validated by comparison with chest computed tomography imaging. Further studies are warranted to validate the utility and applicability of this technology to a variety of clinical scenarios.

1 January 2018 in Circulation Journal
Verified
Journal Article
Open access
MSMitsuo Sobajima
Mitsuo Sobajima
HUHiroshi Ueno
Hiroshi Ueno
HOHiroshi Onoda
Hiroshi Onoda
HKHiroyuki Kuwahara
Hiroyuki Kuwahara
STShuhei Tanaka
Shuhei Tanaka
KKKoichiro Kinugawa
Koichiro Kinugawa
There is a consensus that overactivation of the cardiac sympathetic nervous system (CSN) proportionately increases the severity of heart failure and is accompanied by worse prognosis. Because it is unknown whether patients with aortic valve stenosis (AS) have similar CSN activation, we investigated the effect of transcatheter aortic valve implantation (TAVI).Methods and Results:We enrolled 31 consecutive patients with AS treated by TAVI. 123I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy was performed at baseline and at 2 weeks after TAVI. At baseline, the early heart-mediastinum ratio (H/M) was within normal limits (3.0±0.5), but the delayed H/M was low (2.6±0.6) and the washout rate (WR) was high (34±13%). WR negatively correlated with aortic valve area (r=-0.389, P<0.01) and cardiac output (r=-0.595, P<0.01) and positively correlated with norepinephrine (r=0.519, P<0.01) and log NT-proBNP level (r=0.613, P<0.01). After TAVI, there were significant decreases in the norepinephrine level (366±179 ng/mL vs. 276±125 ng/mL, P<0.01) and WR (34±13 vs. 26±11%, P<0.01). The WR of MIBG was a useful marker of CSN activity and severity of AS. Immediate improvement of CSN activity after TAVI implied that AS hemodynamics per se enhanced CSN.

18 March 2021 in Open Heart
Verified
Journal Article
Open access
PDF file
MMMasaki Miyasaka
Masaki Miyasaka
NTNorio Tada
Norio Tada
MTMasataka Taguri
Masataka Taguri
SKShigeaki Kato
Shigeaki Kato
YEYusuke Enta
Yusuke Enta
KHKentaro Hayashida
Kentaro Hayashida
Background: The balloon-expandable SAPIEN 3 (S3) is superior to the older-generation balloon-expandable SAPIEN XT (XT) in a lower incidence of paravalvular aortic regurgitation, lower complication rates and better survival in transcatheter aortic valve implantation (TAVI). However, prosthesis–patient mismatch (PPM) more frequently occurs in S3 than XT. Further, little information is available on PPM after TAVI using S3 in Asians. This study aims to determine the incidence and predictors of PPM in S3 by focusing on the difference between S3 and XT using data from a Japanese multicentre registry. Methods: From the Optimised transCathEter vAlvular iNtervention-TAVI (OCEAN-TAVI) registry, 2134 patients undergoing TAVI using S3 or XT were included. PPM was defined as moderate if ≧0.65 but ≦0.85 cm2/m2 or severe if <0.65 cm2/m2 at the indexed effective orifice area by postprocedural echocardiography. Results: The incidence of moderate and severe PPM in S3 was 13.3% and 1.3%, respectively. The 20 mm transcatheter heart valve (THV) was more frequently used in S3 than XT (7.4% vs 2.4%, p<0.0001). PPM was more frequently observed in S3 than XT (14.7% vs 8.8%, p<0.0001). Multivariate logistic regression analysis revealed S3 predicted PPM (OR 1.92 (95% CI 1.35 to 2.74), p=0.0003). The mutual predictors for PPM between S3 and XT were younger age, larger body surface area, smaller aortic valve area, no balloon postdilatation and the use of 20 mm and 23 mm THV. When comparing 23 mm, 26 mm and 29 mm S3, the ORs of 20 mm S3 were 5.67 (95% CI 2.88 to 11.12), 19.24 (95% CI 8.13 to 46.86) and 51.03 (95% CI 12.28 to 280.77), respectively. Conclusions: The incidence of PPM after TAVI using S3 was 14.6% overall in this Asian population. PPM was more frequently observed in S3 than XT. A considerable number of patients were treated by the 20 mm S3 in an Asian cohort. The 20 mm THV was identified as a strong predictor for PPM.