Ivaylo Christov

Ivaylo Christov


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
IJIrena Jekova
Irena Jekova
ICIvaylo Christov
Ivaylo Christov
Vessela KrastevaVessela Krasteva
Vessela Krasteva
This study investigates the use of atrioventricular (AV) synchronization as an important diagnostic criterion for atrial fibrillation and flutter (AF) using one to twelve ECG leads. Heart rate, lead-specific AV conduction time, and P-/f-wave amplitude were evaluated by three representative ECG metrics (mean value, standard deviation), namely RR-interval (RRi-mean, RRi-std), PQ-interval (PQi-mean, PQI-std), and PQ-amplitude (PQa-mean, PQa-std), in 71,545 standard 12-lead ECG records from the six largest PhysioNet CinC Challenge 2021 databases. Two rhythm classes were considered (AF, non-AF), randomly assigning records into training (70%), validation (20%), and test (10%) datasets. In a grid search of 19, 55, and 83 dense neural network (DenseNet) architectures and five independent training runs, we optimized models for one-lead, six-lead (chest or limb), and twelve-lead input features. Lead-set performance and SHapley Additive exPlanations (SHAP) input feature importance were evaluated on the test set. Optimal DenseNet architectures with the number of neurons in sequential [1st, 2nd, 3rd] hidden layers were assessed for sensitivity and specificity: DenseNet [16,16,0] with primary leads (I or II) had 87.9–88.3 and 90.5–91.5%; DenseNet [32,32,32] with six limb leads had 90.7 and 94.2%; DenseNet [32,32,4] with six chest leads had 92.1 and 93.2%; and DenseNet [128,8,8] with all 12 leads had 91.8 and 95.8%, indicating sensitivity and specificity values, respectively. Mean SHAP values on the entire test set highlighted the importance of RRi-mean (100%), RR-std (84%), and atrial synchronization (40–60%) for the PQa-mean (aVR, I), PQi-std (V2, aVF, II), and PQi-mean (aVL, aVR). Our focus on finding the strongest AV synchronization predictors of AF in 12-lead ECGs would lead to a comprehensive understanding of the decision-making process in advanced neural network classifiers. DenseNet self-learned to rely on a few ECG behavioral characteristics: first, characteristics usually associated with AF conduction such as rapid heart rate, enhanced heart rate variability, and large PQ-interval deviation in V2 and inferior leads (aVF, II); second, characteristics related to a typical P-wave pattern in sinus rhythm, which is best distinguished from AF by the earliest negative P-peak deflection of the right atrium in the lead (aVR) and late positive left atrial deflection in lateral leads (I, aVL). Our results on lead-selection and feature-selection practices for AF detection should be considered for one- to twelve-lead ECG signal processing settings, particularly those measuring heart rate, AV conduction times, and P-/f-wave amplitudes. Performances are limited to the AF diagnostic potential of these three metrics. SHAP value importance can be used in combination with a human expert’s ECG interpretation to change the focus from a broad observation of 12-lead ECG morphology to focusing on the few AV synchronization findings strongly predictive of AF or non-AF arrhythmias. Our results are representative of AV synchronization findings across a broad taxonomy of cardiac arrhythmias in large 12-lead ECG databases.

15 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Vessela KrastevaVessela Krasteva
Vessela Krasteva
ICIvaylo Christov
Ivaylo Christov
SNStefan Naydenov
Stefan Naydenov
TSTodor Stoyanov
Todor Stoyanov
IJIrena Jekova
Irena Jekova
Considering the significant burden to patients and healthcare systems globally related to atrial fibrillation (AF) complications, the early AF diagnosis is of crucial importance. In the view of prominent perspectives for fast and accurate point-of-care arrhythmia detection, our study optimizes an artificial neural network (NN) classifier and ranks the importance of enhanced 137 diagnostic ECG features computed from time and frequency ECG signal representations of short single-lead strips available in 2017 Physionet/CinC Challenge database. Based on hyperparameters’ grid search of densely connected NN layers, we derive the optimal topology with three layers and 128, 32, 4 neurons per layer (DenseNet-3@128-32-4), which presents maximal F1-scores for classification of Normal rhythms (0.883, 5076 strips), AF (0.825, 758 strips), Other rhythms (0.705, 2415 strips), Noise (0.618, 279 strips) and total F1 relevant to the CinC Challenge of 0.804, derived by five-fold cross-validation. DenseNet-3@128-32-4 performs equally well with 137 to 32 features and presents tolerable reduction by about 0.03 to 0.06 points for limited input sets, including 8 and 16 features, respectively. The feature reduction is linked to effective application of a comprehensive method for computation of the feature map importance based on the weights of the activated neurons through the total path from input to specific output in DenseNet. The detailed analysis of 20 top-ranked ECG features with greatest importance to the detection of each rhythm and overall of all rhythms reveals DenseNet decision-making process, noticeably corresponding to the cardiologists’ diagnostic point of view.

4 February 2017 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
ICIvaylo Christov
Ivaylo Christov
TNTatyana Neycheva
Tatyana Neycheva
RSRamun Schmid
Ramun Schmid
TSTodor Stoyanov
Todor Stoyanov
RARoger Abächerli
Roger Abächerli

14 September 2017
Verified
Conference Paper
Closed access
ICIvaylo Christov
Ivaylo Christov
Vessela KrastevaVessela Krasteva
Vessela Krasteva
ISIana Simova
Iana Simova
TNTatyana Neycheva
Tatyana Neycheva
RSRamun Schmid
Ramun Schmid

14 September 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
GBGiovanni Bortolan
Giovanni Bortolan
ICIvaylo Christov
Ivaylo Christov
ISIana Simova
Iana Simova
The main objective of this study is to propose relatively simple techniques for the automatic diagnosis of electrocardiogram (ECG) signals based on a classical rule-based method and a convolutional deep learning architecture. The validation task was performed in the framework of the PhysioNet/Computing in Cardiology Challenge 2020, where seven databases consisting of 66,361 recordings with 12-lead ECGs were considered for training, validation and test sets. A total of 24 different diagnostic classes are considered in the entire training set. The rule-based method uses morphological and time-frequency ECG descriptors that are defined for each diagnostic label. These rules are extracted from the knowledge base of a cardiologist or from a textbook, with no direct learning procedure in the first phase, whereas a refinement was tested in the second phase. The deep learning method considers both raw ECG and median beat signals. These data are processed via continuous wavelet transform analysis, obtaining a time-frequency domain representation, with the generation of specific images (ECG scalograms). These images are then used for the training of a convolutional neural network based on GoogLeNet topology for ECG diagnostic classification. Cross-validation evaluation was performed for testing purposes. A total of 217 teams submitted 1395 algorithms during the Challenge. The diagnostic accuracy of our algorithm produced a challenge validation score of 0.325 (CPU time = 35 min) for the rule-based method, and a 0.426 (CPU time = 1664 min) for the deep learning method, which resulted in our team attaining 12th place in the competition.

24 April 2018 in Medical Engineering & Physics
Verified
Journal Article
Closed access
ICIvaylo Christov
Ivaylo Christov
RRR. Raikova
R. Raikova
Silvija Koleva AngelovaSilvija Koleva Angelova
Silvija Koleva Angelova
Trunk muscle electromyographic (EMG) signals are often contaminated by the electrical activity of the heart. During low or moderate muscle force, these electrocardiographic (ECG) signals disturb the estimation of muscle activity. Butterworth high-pass filters with cut-off frequency of up to 60 Hz are often used to suppress the ECG signal. Such filters disturb the EMG signal in both frequency and time domain. A new method based on the dynamic application of Savitzky-Golay filter is proposed. EMG signals of three left trunk muscles and pure ECG signal were recorded during different motor tasks. The efficiency of the method was tested and verified both with the experimental EMG signals and with modeled signals obtained by summing the pure ECG signal with EMG signals at different levels of signal-to-noise ratio. The results were compared with those obtained by application of high-pass, 4th order Butterworth filter with cut-off frequency of 30 Hz. The suggested method is separating the EMG signal from the ECG signal without EMG signal distortion across its entire frequency range regardless of amplitudes. Butterworth filter suppresses the signals in the 0-30 Hz range thus preventing the low-frequency analysis of the EMG signal. An additional disadvantage is that it passes high-frequency ECG signal components which is apparent at equal and higher amplitudes of the ECG signal as compared to the EMG signal. The new method was also successfully verified with abnormal ECG signals.