Wiktor Harmatys

Dr. Wiktor Harmatys

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
WHWiktor Harmatys
Wiktor Harmatys
Adam GąskaAdam Gąska
Adam Gąska
PGPiotr Gąska
Piotr Gąska
MGMaciej Gruza
Maciej Gruza
Jerzy A. SładekJerzy A. Sładek
Jerzy A. Sładek
Currently the Coordinate Measuring Technique is facing new challenges both in terms of used methodology and a speed of measurement. More and more often modern optical systems or multisensor systems replace classic solutions. Measurement performed using the optical system is more vulnerable to incorrect points acquisition due to such factors as an inadequate focus or parameters of applied illumination. This article examines the effect of an increasing illumination on the measurement result. A glass reference plate with marked circles and a hole plate standard were used for the measurements performed on a multi-sensor machine Zeiss O’ Inspect 442. The experiment consisted of measurements of standard objects with different values of the backlight at the maximum magnification. Such approach allows to assess the influence of controlled parameter on errors of diameter and form measurements as well as an uncertainty of measurements by determination of ellipses of point repeatability. The analysis of the obtained results shows that increasing backlight mainly affects the result of the diameter measurement.

1 May 2025 in Materials
Verified
Journal Article
Open access
PDF file
WHWiktor Harmatys
Wiktor Harmatys
Adam GąskaAdam Gąska
Adam Gąska
PGPiotr Gąska
Piotr Gąska
MGMaciej Gruza
Maciej Gruza
This study investigates the influence of isopropyl alcohol (IPA) washing time on the surface roughness of stereolithography (SLA)-printed parts fabricated using the Formlabs Form 3B+ printer. Three photopolymer resins provided by the manufacturer were evaluated: Gray, Tough 2000, and Rigid 10K. Samples were printed in standardized geometries and post-processed under controlled conditions, with IPA washing times ranging from 6 to 30 min, followed by UV post-curing. The surface roughness parameters (Ra, Rz, Rt, and RSm) were measured using a Taylor Hobson Form Talysurf i-Series profilometer under metrologically controlled conditions. The results revealed a clear correlation between increased IPA exposure time and improved surface finish, though the magnitude and monotonicity of this effect were material dependent. Rigid 10K exhibited the most consistent reduction in roughness with longer washing, while Tough 2000 showed substantial improvement with extended durations but also demonstrated temporary surface degradation at intermediate wash times. Gray resin achieved near-optimal roughness after moderate rinsing, with orientation-dependent differences observed. The findings indicate that the careful optimization of washing duration can significantly enhance the surface quality in SLA prints, potentially eliminating the need for secondary finishing processes. The implications are relevant to both industrial and medical applications where dimensional fidelity and surface smoothness are critical. Recommendations for optimal washing durations are proposed for each material, and directions for further research are outlined.

25 September 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KKKonrad Kobiela
Konrad Kobiela
MJMichał Jedynak
Michał Jedynak
WHWiktor Harmatys
Wiktor Harmatys
MKMarcin Krawczyk
Marcin Krawczyk
Jerzy A. SładekJerzy A. Sładek
Jerzy A. Sładek
The laser projector based on the laser galvanometer scanning system enables the projection of CAD-based laser images onto geometrical objects. Furthermore, the system can perform a scan of components in order to control proper positioning (e.g., welded structures). We decided to conduct research aimed at determining the suitability of such systems for length measurements and assess their accuracy. These systems are commonly calibrated with the use of flat calibration boards, although their capability of projecting and scanning 3D objects. For this reason, a new method based on ISO 10360 has been proposed. Analysis of the system’s ability to perform length measurements, selection of a reference standard, and the tested device accuracy were the main objectives of the study. A ball-bar with a nominal length of 3000 mm was chosen as a reference standard. Positions of the reference element in the workspace were determined, and three series of five measured deviations were performed in each setting. The obtained values of measurement errors prove that it is possible to use ball-bar standards to assess the accuracy of the described systems, which is defined by the equation MPE(E0) = ±0.5 mm. The proposed method could be adapted to perform more complex analyzes in this area.

8 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MGMaciej Gruza
Maciej Gruza
Adam GąskaAdam Gąska
Adam Gąska
Jerzy A. SładekJerzy A. Sładek
Jerzy A. Sładek
SSSlavenko Stojadinovic
Slavenko Stojadinovic
Vidosav D. MajstorovicVidosav D. Majstorovic
Vidosav D. Majstorovic
WHWiktor Harmatys
Wiktor Harmatys
Laser tracking systems are widely used in large-scale metrology of geometric quantities. Their importance is confirmed by the fact that one of the parts of the ISO 10360 series of standards has been devoted to the issue of assessing their accuracy (ISO 10360-10). A laser tracker is a device whose final measurement result is calculated using indications from various subsystems included in it, such as devices for measuring length and angle. The analysis of these individual impacts can be useful in creating simulation models of accuracy which, in regard to the Industry 4.0 concept, seem to be the most justified in terms of speed of operation and ease of use. For this reason, it may be particularly important to undertake research on the accuracy of this component in isolation from other factors affecting the measurement of the coordinates of the point. The article describes a method that allows separation of the length measurement error from the other components. The method uses a high-accuracy interferometer which is treated as a reference system that allows for the comparison of indications obtained using the tested distance measurement system. Thanks to the proposed method, it is possible to minimize errors from the optical system and other measuring systems. The use of a precise linear guide allows the reduction of errors related to the implementation of linear motion. The article presents the test method and the results obtained from performed experiments, as well as formulates conclusions and the directions of further development.

10 June 2022 in Materials
Verified
Journal Article
Open access
PDF file
WHWiktor Harmatys
Wiktor Harmatys
PGPiotr Gąska
Piotr Gąska
Adam GąskaAdam Gąska
Adam Gąska
MGMaciej Gruza
Maciej Gruza
MJMichał Jedynak
Michał Jedynak
MMMichael Marxer
Michael Marxer
Multisensor CMMs are systems with an established position on the market, but their popularity still grows, as they provide access to the advantages offered by tactile and contactless measurement methods. Yet there are still questions of the comparability of results obtained using the optical and tactile operation modes of multisensor system. This phenomenon can be assessed by measuring appropriate gauges, most often reference rings or spheres. Due to the completely different nature of probing processes for tactile and contactless measurements, the material from which reference object is made may significantly affect measurement results. In order to assess the influence of this factor on measurement accuracy, three reference spheres made from different materials were measured on optical multisensor CMMs. Measurements involved tactile measurements as well as optical measurements made using different probing systems: a video probe and white light sensor. Results obtained from performed experiments show large differences depending on the material used for spherical standard production. On the basis of obtained results, it can be stated that the best material for a reference object that can be used for comparability tests of tactile and optical measurements is a composite of alumina with at least one oxidic additive.

4 December 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WZWiesław Zaborowski
Wiesław Zaborowski
WHWiktor Harmatys
Wiktor Harmatys
Adam GąskaAdam Gąska
Adam Gąska
This paper presents the results of preliminary tests carried out in an organization producing products for the automotive industry. From the many available systems used in this research, different values of results were obtained; these differences cause doubts among people deciding about the process approval and start of production. The main aim of the research presented in the article is to determine the influence of various factors on the measurement results, especially to compare the results of measurements obtained with the optical sensor, which is used during measurements with the use of a multisensor measuring machine. The results obtained with the use of the height gauge, which is used alternatively in the organization, raise further doubts. Experience has shown that the methodology and definition of the alignment during the measurement, which is different for each of the systems, have a great influence.