Dimitra Kourti

Ms. Dimitra Kourti

Department of Chemistry, National and Kapodistrian University of Athens, Athens, Attikí, Greece
+1

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
Dimitra KourtiDimitra Kourti
Dimitra Kourti
MAMichailia Angelopoulou
Michailia Angelopoulou
Panagiota PetrouPanagiota Petrou
Panagiota Petrou
Sotirios KakabakosSotirios Kakabakos
Sotirios Kakabakos
Optical immunosensors are one of the most popular categories of immunosensors with applications in many fields including diagnostics and environmental and food analysis. The latter field is of particular interest not only for scientists but also for regulatory authorities and the public since food is essential for life but can also be the source of many health problems. In this context, the current review aims to provide an overview of the different types of optical immunosensors focusing on their application for the determination of pathogenic bacteria in food samples. The optical immunosensors discussed include sensors based on evanescent wave transduction principles including surface plasmon resonance (SPR), fiber-optic-, interferometric-, grating-coupler-, and ring-resonator-based sensors, as well as reflectometric, photoluminescence, and immunosensors based on surface-enhanced Raman scattering (SERS). Thus, after a short description of each transduction technique, its implementation for the immunochemical determination of bacteria is discussed. Finally, a short commentary about the future trends in optical immunosensors for food safety applications is provided.

24 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Dimitra KourtiDimitra Kourti
Dimitra Kourti
GGGeorgia Geka
Georgia Geka
LNLidia Nemtsov
Lidia Nemtsov
Soha AhmadiSoha Ahmadi
Soha Ahmadi
Anastasios EconomouAnastasios Economou
Anastasios Economou
Michael ThompsonMichael Thompson
Michael Thompson
Oxytetracycline (OTC) is a widely employed antibiotic in veterinary treatment and in the prevention of infections, potentially leaving residues in animal-derived food products, such as milk, that are consumed by humans. Given the detrimental effects of prolonged human exposure to antibiotics, it has become imperative to develop precise and sensitive methods for monitoring the presence of OTC in food. Herein, we describe the development and results of a preliminary label-free electrochemical aptasensor with antifouling properties designed to detect OTC in milk samples. The sensor was realized by modifying a gold screen-printed electrode with α-lipoic acid–NHS and an amine-terminated aptamer. Different electrochemical techniques were used to study the steps of the fabrication process and to quantify OTC in the presence of the Fe(CN)64−/Fe(CN)63− redox couple The detectable range of concentrations satisfy the maximum residue limits set by the European Union, with an limit of detection (LOD) of 14 ng/mL in phosphate buffer (BP) and 10 ng/mL in the milk matrix, and a dynamic range of up to 500 ng/mL This study is a steppingstone towards the implementation of a sensitive monitoring method for OTC in dairy products.

26 August 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
MAMichailia Angelopoulou
Michailia Angelopoulou
Dimitra KourtiDimitra Kourti
Dimitra Kourti
MMMaria Mertiri
Maria Mertiri
Panagiota PetrouPanagiota Petrou
Panagiota Petrou
Sotirios KakabakosSotirios Kakabakos
Sotirios Kakabakos
Christos KokkinosChristos Kokkinos
Christos Kokkinos
Salmonella is one of the leading causes of foodborne illnesses worldwide, with poultry products being a major source of contamination. Thus, the detection of salmonella in commercial poultry products is crucial to minimize the effects on public health. Electrochemical sensors are promising tools for bacteria detection due to their sensitivity, simplicity, and potential for on-site analysis. In this work, a three-dimensional (3D) printed electrochemical immunosensor for the determination of Salmonella typhimurium in fresh chicken through a sandwich immunoassay employing biotinylated anti-S. typhimurium antibody followed by streptavidin labeled with Cd/Se ZnS quantum dots (QDs) is presented. The device features three carbon-black polylactic acid electrodes and a holder, and the quantification of S. typhimurium is performed by anodic stripping voltametric (ASV) determination of the Cd(II) released after acidic dissolution of the QDs. To enhance sensitivity, an electroplated bismuth film was deposited on the working electrode, achieving a detection limit of 5 cfu/mL in a total assay time of 25 min, whereas 5 h of sample pre-enrichment was required for the detection of 1 cfu/25 mL of chicken rinse and chicken broth. The method is accurate, with %recovery values ranging from 93.3 to 113% in fresh chicken samples, and repeatable with intra- and inter- assay coefficient of variations <2 and 5%, respectively, indicating the suitability of the proposed immunosensor for the detection of S. typhimurium at the point-of-need.

30 May 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
MAMichailia Angelopoulou
Michailia Angelopoulou
Dimitra KourtiDimitra Kourti
Dimitra Kourti
KMKonstantinos Misiakos
Konstantinos Misiakos
Anastasios EconomouAnastasios Economou
Anastasios Economou
Panagiota PetrouPanagiota Petrou
Panagiota Petrou
Sotirios KakabakosSotirios Kakabakos
Sotirios Kakabakos
Aflatoxin M1 (AFM1) is detected in the milk of animals after ingestion of aflatoxin B1-contaminated food; since 2002, it has been categorized as a group I carcinogen. In this work, a silicon-based optoelectronic immunosensor for the detection of AFM1 in milk, chocolate milk, and yogurt has been developed. The immunosensor consists of ten Mach–Zehnder silicon nitride waveguide interferometers (MZIs) integrated on the same chip with the respective light sources, and an external spectrophotometer for transmission spectra collection. The sensing arm windows of MZIs are bio-functionalized after chip activation with aminosilane by spotting an AFM1 conjugate with bovine serum albumin. For AFM1 detection, a three-step competitive immunoassay is employed, including the primary reaction with a rabbit polyclonal anti-AFM1 antibody, followed by biotinylated donkey polyclonal anti-rabbit IgG antibody and streptavidin. The assay duration was 15 min with limits of detection of 0.005 ng/mL in both full-fat and chocolate milk, and 0.01 ng/mL in yogurt, which are lower than the maximum allowable concentration of 0.05 ng/mL set by the European Union. The assay is accurate (% recovery values 86.7–115) and repeatable (inter- and intra-assay variation coefficients <8%). The excellent analytical performance of the proposed immunosensor paves the way for accurate on-site AFM1 determination in milk.

29 November 2024 in Toxins
Verified
Journal Article
Open access
PDF file
Dimitra KourtiDimitra Kourti
Dimitra Kourti
MAMichailia Angelopoulou
Michailia Angelopoulou
Panagiota PetrouPanagiota Petrou
Panagiota Petrou
Sotirios KakabakosSotirios Kakabakos
Sotirios Kakabakos
Aflatoxin M1 (AFM1) exposure through dairy products is associated with adverse health effects, including hepatotoxicity and carcinogenicity. Therefore, the AFM1 presence in milk and dairy products is strictly regulated. In this context, the current work focuses on the investigation of different competitive enzyme immunoassay configurations for the determination of AFM1 in milk with high sensitivity and short assay duration. Amongst the configurations tested, the one based on incubation of the anti-AFM1 specific antibody along with the calibrators/samples and a biotinylated conjugate of AFM1 with bovine serum albumin (BSA) in microwells coated with a secondary antibody provided a six-fold lower detection limit than the configuration involving immobilized AFM1-BSA conjugate and liquid phase antibody. The detection limit achieved was 5.0 pg/mL, with a dynamic range of up to 2.0 ng/mL. The assay was repeatable with intra- and inter-assay coefficients of variations lower than 3.2% and 6.5%, respectively, and accurate with recovery values from 87.5 to 108%. Moreover, the assay was completed in 1.5 h. The excellent analytical characteristics and short analysis time make the proposed assay suitable for use by the food industry. Furthermore, the proposed configuration could be employed to enhance the detection sensitivity of competitive immunoassays for other low-molecular-weight analytes.

26 March 2025 in Toxins
Verified
Journal Article
Open access
PDF file
Dimitra KourtiDimitra Kourti
Dimitra Kourti
MAMichailia Angelopoulou
Michailia Angelopoulou
Eleni MakaronaEleni Makarona
Eleni Makarona
Anastasios EconomouAnastasios Economou
Anastasios Economou
Panagiota PetrouPanagiota Petrou
Panagiota Petrou
Sotirios KakabakosSotirios Kakabakos
Sotirios Kakabakos
Aflatoxin M1 (AFM1) appears in the milk of animals that have consumed feed contaminated with aflatoxin B1. AFM1 presence in milk is regulated by the European Commission, which has set the maximum allowable limits for adult and infant consumption to 50 and 25 pg/mL, respectively. Here, a rapid and sensitive method for detecting AFM1 in milk based on an immersible silicon photonic chip is presented. The chip features two U-shaped silicon nitride waveguides formed as Mach–Zehnder interferometers. One interferometer is functionalized with AFM1–bovine serum albumin conjugate and the other with BSA to serve as a blank. The chip is connected to a broad-band white LED and a spectrophotometer by a bifurcated optical fiber and an assay is performed by immersing the chip in a mixture of milk with the anti-AFM1 antibody. Then, the chip is sequentially immersed in biotinylated anti-rabbit IgG antibody and streptavidin solutions for signal enhancement. The assay is completed in 20 min and the detection limit for AFM1 in undiluted milk is 20 pg/mL. Given its analytical performance and the absence of pumps and fluidics that lead to a compact instrument design, the proposed immunosensor is ideal for the on-site detection of AFM1 in milk samples.