A flexible grounding system is a system in which the neutral point of the power supply is grounded via the arc suppression coil in parallel with a low-resistance resistor. When operating normally or a temporary ground fault occurs, the arc suppression coil is used for grounding, whereas the small resistance is switched on when a permanent ground fault occurs. At present, the problem of low protection sensitivity when a high-resistance ground fault occurs in a flexible grounding system has not been solved yet. According to the characteristics of low waveform similarity between the faulty line and the non-faulty line when a single-phase grounding fault occurred, a new faulty line selection method based on a combination of Dynamic Time Warping (DTW) distance and the transient projection method is proposed in this paper. Firstly, the fault transient signal is extracted by a digital filter as a basis for faulty line selection. Secondly, the transient zero-sequence current of each line is projected onto the busbar transient zero-sequence voltage, and the projected DTW distance of each line is calculated. Finally, according to the calculation formula of waveform comprehensive similarity coefficient, the Comprehensive DTW (CDTW) distance is obtained, and the top three CDTW distance values are selected to determine the faulty line. If the maximum value is greater than the sum of the other two CDTW distance values, the line corresponding to the maximum value is judged as the faulty line; otherwise, it is judged as a busbar fault. The simulation results based on MATLAB/Simulink and field data test show that the method can accurately determine the faulty line under diverse fault conditions.
6 February 2023 in International Journal of Energy Research
Accurate estimations of the temperature and the state-of-charge (SOC) are of extreme importance for the safety of lithium-ion battery operation. Traditional battery temperature and SOC estimation methods often omit the relation between battery temperature and SOC, which may lead to significant errors in the estimations. This study presents a coupled electrothermal battery model and a coestimation method for simultaneously estimating the temperature and SOC of lithium-ion batteries. The coestimation method is performed by a coupled model-based dual extended Kalman filter (DEKF). The coupled estimators utilizing electrochemical impedance spectroscopy (EIS) measurements, rather than utilizing direct battery surface measurements, are adopted to estimate the battery temperature and SOC, respectively. The information being exchanged between the temperature estimator and the SOC estimator effectively improves the estimation accuracy. Extensive experiments show that, in contrast with the EKF-based separate estimation method, the DEKF-based coestimation method is more favorable in reducing errors for estimating both the temperature and SOC even if the battery core temperature has increased by 17°C or more during the process of test.
Distributed control has good real-time performance and can better meet the control requirements of active distribution networks with a large number of distributed generations. Some distributed applications require real-time feeder topology to achieve control. In this paper, the demand for distributed control applications for feeder real-time topology is analyzed. Based on IEC 61850 modeling method, a new cell topology logic node and a new topology slice node are built to express feeder topology. Using the topology information of smart terminal unit (STU) configuration and the current status information of switchgear, based on the depth-first search, the feeder real-time topology identification can be realized, which meets the application requirements of distributed control. The study case verified the effectiveness of the method.
Under the low voltage ride through (LVRT) control strategy, the inverter interfaced distributed generation (IIDG) needs to change the output mode of the inverter according to the voltage of the connected nodes. The short-circuit current is related to the system rated capacity, network short-circuit impedance, and distributed power output. So, based on the deep learning algorithm, a predicting method of the voltage drop is proposed. By predicting the voltage of connected nodes, the output mode of IIDG can be determined based on the LVRT control. Thus, the fault calculation model of IIDG is accurately established. Compared with the three-phase asymmetric Gaussian fault calculation method, the proposed method can achieve fault calculation accurately. Finally, a case study is built to verify the effectiveness of the proposed method. The results indicate that the proposed method can make accurate voltage prediction and improve the computation speed of the fault calculation.
In the application process of distributed feeder automation (FA) that is based on peer-to-peer exchange of measurement and control data between smart terminal units (STUs), there is an urgent need for standardized communication interaction and necessary security protection. This paper proposes an IEC 61850 communication mapping scheme using built-in secure extensible messaging and presence protocol (XMPP) and the generic object oriented substation event based on the user datagram protocol (GOOSE over UDP) and a security protection scheme based on hash to obtain random subsets (HORS); one-time signature algorithm is used to ensure the communication safety of GOOSE messages. The agent-based distributed FA test system is developed with the STUs. The test results show the scheme can meet the requirements of the quick distributed feeder automation.
In active distribution networks (DNs), distributed energy resources (DERs) must be disconnected from the grid prior to automatic reclosing actions. Many scholars have proposed non-voltage checking reclosing methods, but a significant challenge arises; many substations lack line-side voltage transformers (LSVTs), making these schemes impractical. To address this, we introduce a time-limited adaptive automatic reclosing (TLAR) method that integrates DERs’ anti-islanding protection (AIP) with automatic reclosing. This method estimates the AIP action time using bus-side voltage measurements before the system-side protection (SSP) is tripped and adjusts the reclosing time accordingly to enhance power supply reliability. Simulations using PSCAD validate the method’s effectiveness. The TLAR method is well-suited for distribution lines without conditions for non-voltage checking, is cost-effective, easy to implement, and contributes to power system stability.