Xinhui Zhang

Prof. Dr. Xinhui Zhang


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2022 in Energies
Verified
Journal Article
Open access
PDF file
YHYu He
Yu He
XZXinhui Zhang
Xinhui Zhang
WWWenhao Wu
Wenhao Wu
JZJun Zhang
Jun Zhang
WBWenyuan Bai
Wenyuan Bai
YCYu Chen
Yu Chen
A flexible grounding system is a system in which the neutral point of the power supply is grounded via the arc suppression coil in parallel with a low-resistance resistor. When operating normally or a temporary ground fault occurs, the arc suppression coil is used for grounding, whereas the small resistance is switched on when a permanent ground fault occurs. At present, the problem of low protection sensitivity when a high-resistance ground fault occurs in a flexible grounding system has not been solved yet. According to the characteristics of low waveform similarity between the faulty line and the non-faulty line when a single-phase grounding fault occurred, a new faulty line selection method based on a combination of Dynamic Time Warping (DTW) distance and the transient projection method is proposed in this paper. Firstly, the fault transient signal is extracted by a digital filter as a basis for faulty line selection. Secondly, the transient zero-sequence current of each line is projected onto the busbar transient zero-sequence voltage, and the projected DTW distance of each line is calculated. Finally, according to the calculation formula of waveform comprehensive similarity coefficient, the Comprehensive DTW (CDTW) distance is obtained, and the top three CDTW distance values are selected to determine the faulty line. If the maximum value is greater than the sum of the other two CDTW distance values, the line corresponding to the maximum value is judged as the faulty line; otherwise, it is judged as a busbar fault. The simulation results based on MATLAB/Simulink and field data test show that the method can accurately determine the faulty line under diverse fault conditions.

5 July 2022 in Energies
Verified
Journal Article
Open access
PDF file
YHYu He
Yu He
XZXinhui Zhang
Xinhui Zhang
RWRui Wang
Rui Wang
MCMengzhu Cheng
Mengzhu Cheng
ZGZhen Gao
Zhen Gao
WYWenxin Yu
Wenxin Yu
When a single-phase grounding fault occurs in a resonant grounding system, the determination of the fault location remains a significant challenge due to the small fault current and the instability of the grounding arc. In order to solve the problem of low protection sensitivity when a high-resistance grounding fault occurs in a resonant grounding system, this paper proposes a fault location method based on the combination of dynamic time warping (DTW) distance and fuzzy C-means (FCM) clustering. By analyzing the characteristics of the zero-sequence current upstream and downstream of the fault point when a single-phase grounding fault occurs in the resonant grounding system, it is concluded that the waveform similarity on both sides of the fault point is low. DTW distance can be used to measure the similarity of two time series, and has the characteristics of good fault tolerance and synchronization error tolerance. According to the rule that the DTW value of faulty section is much larger than that of nonfaulty sections, FCM clustering is used to classify the DTW value of each section. The membership degree matrix and cluster centers are obtained. In the membership degree matrix, the section corresponding to the data in a class of their own is the faulty section, and all other data correspond to the nonfaulty section; otherwise, it is a fault occurring at the end of the line. The simulation results of MATLAB/Simulink and the field data test show that the method can accurately locate the faulty section.

19 February 2023 in Energy Technology
Verified
Journal Article
Closed access
SXShuyu Xie
Shuyu Xie
XZXinhui Zhang
Xinhui Zhang
WBWenyuan Bai
Wenyuan Bai
AGAiyu Guo
Aiyu Guo
WLWenlong Li
Wenlong Li
RWRui Wang
Rui Wang

6 February 2023 in International Journal of Energy Research
Verified
Journal Article
Open access
PDF file
WBWenyuan Bai
Wenyuan Bai
XZXinhui Zhang
Xinhui Zhang
ZGZhen Gao
Zhen Gao
SXShuyu Xie
Shuyu Xie
KPKe Peng
Ke Peng
YCYu Chen
Yu Chen
Accurate estimations of the temperature and the state-of-charge (SOC) are of extreme importance for the safety of lithium-ion battery operation. Traditional battery temperature and SOC estimation methods often omit the relation between battery temperature and SOC, which may lead to significant errors in the estimations. This study presents a coupled electrothermal battery model and a coestimation method for simultaneously estimating the temperature and SOC of lithium-ion batteries. The coestimation method is performed by a coupled model-based dual extended Kalman filter (DEKF). The coupled estimators utilizing electrochemical impedance spectroscopy (EIS) measurements, rather than utilizing direct battery surface measurements, are adopted to estimate the battery temperature and SOC, respectively. The information being exchanged between the temperature estimator and the SOC estimator effectively improves the estimation accuracy. Extensive experiments show that, in contrast with the EKF-based separate estimation method, the DEKF-based coestimation method is more favorable in reducing errors for estimating both the temperature and SOC even if the battery core temperature has increased by 17°C or more during the process of test.

29 May 2021 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
WWWenhao Wu
Wenhao Wu
XZXinhui Zhang
Xinhui Zhang
JZJun Zhang
Jun Zhang
YHYu He
Yu He
WBWenyuan Bai
Wenyuan Bai
Neutral non‐effectively grounded mode is widely used in medium‐voltage distribution networks in China. When a single‐phase grounding fault occurs in distribution networks, abundant transient signals will be generated. Here, a fault location method based on improved Hausdorff distance is proposed with transient zero‐sequence current and transient zero‐sequence voltage of bus. First, according to the impedance characteristic analysis of the zero‐sequence network, the selected frequency band (SFB) is determined, and the transient signals in the SFB are extracted by the digital filter. Second, the projection components of transient zero‐sequence currents at each monitoring point of faulty feeder are obtained by the principle of orthogonalization. Finally, the projection component values of each section are calculated by the improved Hausdorff distance, and the maximum value is selected. If the maximum value is much larger than the sum of the values of other sections excluding the maximum value, the section where the maximum value is located is judged as a faulty section, otherwise, the downstream section of the last monitoring point is determined as the faulty section. Matlab/Simulink simulation shows that the proposed method can locate accurately under different fault conditions.

13 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
HGHaotian Ge
Haotian Ge
BXbingyin xu
bingyin xu
XZXinhui Zhang
Xinhui Zhang
YBYongjian Bi
Yongjian Bi
ZZZida Zhao
Zida Zhao
Distribution automation (DA) and Internet of Things (IoT) all need the topology information of power distribution network to support some applications, such as fault diagnosis, network reconfiguration and optimization. IEC 61850 is a general communication model and standard for information exchange between intelligent electronic devices (IEDs). However, it has no mechanism for feeder topology information exchange. This paper solves this problem by developing the corresponding information model. Firstly, a feeder model is established as a container of the equipment along a distribution line. Secondly, logical models, such as terminal and connection nodes, are added to describe the physical connection relationship between the electrical equipment. Taking a circuit breaker as an example, this paper introduces how to add the terminal attribute to an existing logical node (XCBR). The physical connection between the circuit breaker and other electrical equipment is described by adding the logic node LCNN. Then, a new logical node LTPN is added to describe the logical connection between the devices. A new logical node, FTPA, is added to describe the status of the topology analysis and the topology results. Based on these new logical nodes, this paper proposes the mechanism of topology information exchange between IEDs. Three IEDs and the IEEE 13-node model are used to build an experimental environment. The result verifies the effectiveness of this method. More distributed applications can be used to test the validity and interoperability of the proposed model.