Mohammadreza Ebrahimnataj Tiji

Mr. Mohammadreza Ebrahimnataj Tiji

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Farqad Talib NajimFarqad Talib Najim
Farqad Talib Najim
Hayder MohammedHayder Mohammed
Hayder Mohammed
HAHussein M. Taqi Al-Najjar
Hussein M. Taqi Al-Najjar
LTLakshmi Thangavelu
Lakshmi Thangavelu
MMMustafa Z. Mahmoud
Mustafa Z. Mahmoud
PTPouyan Talebizadeh
Pouyan Talebizadeh
Employing phase-change materials (PCM) is considered a very efficient and cost-effective option for addressing the mismatch between the energy supply and the demand. The high storage density, little temperature degradation, and ease of material processing register the PCM as a key candidate for the thermal energy storage system. However, the sluggish response rates during their melting and solidification processes limit their applications and consequently require the inclusion of heat transfer enhancers. This research aims to investigate the potential enhancement of circular fins on intensifying the PCM thermal response in a vertical triple-tube casing. Fin arrays of non-uniform dimensions and distinct distribution patterns were designed and investigated to determine the impact of modifying the fin geometric characteristics and distribution patterns in various spatial zones of the heat exchanger. Parametric analysis on the various fin structures under consideration was carried out to determine the most optimal fin structure from the perspective of the transient melting evolution and heat storage rates while maintaining the same design limitations of fin material and volume usage. The results revealed that changing the fin dimensions with the heat-flow direction results in a faster charging rate, a higher storage rate, and a more uniform temperature distribution when compared to a uniform fin size. The time required to fully charge the storage system (fully melting of the PCM) was found to be reduced by up to 10.4%, and the heat storage rate can be improved by up to 9.3% compared to the reference case of uniform fin sizes within the same fin volume limitations.

9 October 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
SXSun Xinguo
Sun Xinguo
Hayder MohammedHayder Mohammed
Hayder Mohammed
MTMohammadreza Ebrahimnataj Tiji
Mohammadreza Ebrahimnataj Tiji
Jasim M. MahdiJasim M. Mahdi
Jasim M. Mahdi
HMHasan Majdi
Hasan Majdi
Wahiba YaiciWahiba Yaici
Wahiba Yaici
Inherent fluctuations in the availability of energy from renewables, particularly solar, remain a substantial impediment to their widespread deployment worldwide. Employing phase-change materials (PCMs) as media, saving energy for later consumption, offers a promising solution for overcoming the problem. However, the heat conductivities of most PCMs are limited, which severely limits the energy storage potential of these materials. This study suggests employing circular fins with staggered distribution to achieve improved thermal response rates of PCM in a vertical triple-tube heat exchanger involving two opposite flow streams of the heat-transfer fluid (HTF). Since heat diffusion is not the same at various portions of the PCM unit, different fin configurations, fin dimensions and HTF flow boundary conditions were explored using computational studies of melting in the PCM triple-tube system. Staggered configuration of fin distribution resulted in significant increases in the rates of PCM melting. The results indicate that the melting rate and heat charging rate could be increased by 37.2 and 59.1%, respectively, in the case of staggered distribution. Furthermore, the use of lengthy fins with smaller thickness in the vertical direction of the storage unit resulted in a better positive role of natural convection; thus, faster melting rates were achieved. With fin dimensions of 0.666 mm × 15 mm, the melting rate was found to be increased by 23.6%, when compared to the base case of 2 mm × 5 mm. Finally, it was confirmed that the values of the Reynolds number and inlet temperatures of the HTF had a significant impact on melting time savings when circular fins of staggered distribution were included.

9 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
MTMohammadreza Ebrahimnataj Tiji
Mohammadreza Ebrahimnataj Tiji
Jasim M. MahdiJasim M. Mahdi
Jasim M. Mahdi
Hayder MohammedHayder Mohammed
Hayder Mohammed
HMHasan Majdi
Hasan Majdi
AEAbbas Ebrahimi
Abbas Ebrahimi
Wahiba YaiciWahiba Yaici
Wahiba Yaici
The solidification process in a multi-tube latent heat energy system is affected by the natural convection and the arrangement of heat exchanger tubes, which changes the buoyancy effect as well. In the current work, the effect of the arrangement of the tubes in a multi-tube heat exchanger was examined during the solidification process with the focus on the natural convection effects inside the phase change material (PCM). The behavior of the system was numerically analyzed using liquid fraction and energy released, as well as temperature, velocity and streamline profiles for different studied cases. The arrangement of the tubes, considering seven pipes in the symmetrical condition, are assumed at different positions in the system, including uniform distribution of the tubes as well as non-uniform distribution, i.e., tubes concentrated at the bottom, middle and the top of the PCM shell. The model was first validated compared with previous experimental work from the literature. The results show that the heat rate removal from the PCM after 16 h was 52.89 W (max) and 14.85 W (min) for the cases of uniform tube distribution and tubes concentrated at the bottom, respectively, for the proposed dimensions of the heat exchanger. The heat rate removal of the system with uniform tube distribution increases when the distance between the tubes and top of the shell reduces, and increased equal to 68.75 W due to natural convection effect. The heat release rate also reduces by increasing the temperature the tubes. The heat removal rate increases by 7.5%, and 23.7% when the temperature increases from 10 °C to 15 °C and 20 °C, respectively. This paper reveals that specific consideration to the arrangement of the tubes should be made to enhance the heat recovery process attending natural convection effects in phase change heat storage systems.

11 January 2025 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
MTMohammadreza Ebrahimnataj Tiji
Mohammadreza Ebrahimnataj Tiji
SRSina Rezaei
Sina Rezaei
KHKhashayar Hosseinzadeh
Khashayar Hosseinzadeh
SKSami Kaplan
Sami Kaplan
PTPouyan Talebizadeh
Pouyan Talebizadeh
AKAmir Keshmiri
Amir Keshmiri