Tarlochan Sidhu

Prof. Dr. Tarlochan Sidhu

Department of Electrical, Computer and Software Engineering, Faculty of Engineering and Applied Science, University of Ontario Institute of Technology, Oshawa, ON L1G 0C5, Canada
orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2022 in Energies
Verified
Journal Article
Open access
PDF file
Sandra Aragon-AvilesSandra Aragon-Aviles
Sandra Aragon-Aviles
Arvind H. KadamArvind H. Kadam
Arvind H. Kadam
TSTarlochan Sidhu
Tarlochan Sidhu
Sheldon WilliamsonSheldon Williamson
Sheldon Williamson
Different factors affect solar photovoltaic (PV) systems by decreasing input energy and reducing the conversion efficiency of the system. One of these factors is the effect of snow cover on PV panels, a subject lacking sufficient academic research. This paper reviews and compares current research for snow removal in solar PV modules. Additionally, this paper presents the design, analysis and modelling of a smart heating system for solar PV Electric Vehicle (EV) charging applications. The system is based on a bidirectional DC-DC converter that redirects the grid/EV-battery power into heating of the solar PV modules, thus removing snow cover, as well as providing the function of MPPT when required to charge the EV battery pack. A control scheme for each mode of operation was designed. Subsequently, a performance evaluation by simulating the system under various conditions is presented validating the usefulness of the proposed converter to be used in solar PV systems under extreme winter conditions.

1 January 1992 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
TSTarlochan Sidhu
Tarlochan Sidhu
MSManoj Sachdev
Manoj Sachdev
HWH.C. Wood
H.C. Wood
The design, development, and implementation of a computer-aided design (CAD) tool for developing digital controllers and relays are presented. The development includes modeling A/D converters, software, and the necessary logic. Procedures for modeling A/D converters and simulating the software are described. Application of the CAD tool is demonstrated by evaluating and comparing three different designs of a digital overcurrent relay. The designs are evaluated to determine both the speed and accuracy of the relays. The effects of the size of the A/D converters, the word-size used in computations, and the truncation/rounding are included in the simulation. Also described is the algorithm used in the relay design.

9 February 2009 in IET Generation, Transmission & Distribution
Verified
Journal Article
Closed access
VMV. Muthukrishnan
V. Muthukrishnan
TSTarlochan Sidhu
Tarlochan Sidhu
In a power system, every apparatus is equipped with a primary protection to detect faults and isolate the equipment by opening the circuit breaker. Breaker failure (BF) protection is employed as a means of local backup protection to detect failure of a circuit breaker. In this research work, a critical challenge facing numerical BF relays namely longer reset time of current based BF algorithms is examined by means of simulations and realistic experiments. Two new fast resetting algorithms for BF protection with reset time of less than half a power system cycle are proposed as means of enhancing BF protection. Simulations and experiments reflecting realistic conditions were used for performance evaluation of the enhanced BF algorithms. The proposed algorithms have a reset time of around half a cycle compared to 2–3 cycles in the case of a commercial numerical BF relay selected. Results indicate that the new algorithms significantly enhance the numerical BF protection.

4 March 2024 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
PDPaawan Kirankumar Dubal
Paawan Kirankumar Dubal
SDSarasij Das
Sarasij Das
TSTarlochan Sidhu
Tarlochan Sidhu
Breaker Failure Protection trips the backup breakers when the primary breaker fails, causing a significant loss of load. Hence, a cyber-attack on the Breaker Failure Protection scheme may lead to major disturbance in a power system. Currently, there is a lack of literature addressing the cyber-attack on Breaker Failure Protection scheme. This paper proposes a novel Wide Area Measurement-based cyber-attack-resilient Breaker Failure Protection scheme. Modern digital relays have Phasor Measurement Unit (PMU) integrated with them. A digital relay with PMU functionality is called Relay-PMU in this work. The proposed scheme has two parts. Part 1 is named as Synchrophasor-based Fault Validation Algorithm. It checks whether the Breaker Failure Protection operation is genuine or due to a cyber-attack. Breaker Failure Protection Relay-PMU will trigger the Part 1 of the proposed scheme which runs in a Phasor Data Concentrator. A novel concept named Dynamic Relay White-listing is proposed to avoid the usage of phasors from the susceptible Relay-PMUs. Part 2 is the modifications to the logics of the existing common Breaker Failure Protection schemes to incorporate the decision from the Synchrophasor-based Fault Validation Algorithm. The proposed scheme is computationally efficient and compatible with all common Breaker Failure Protection schemes. PSCAD simulations of the IEEE-118 bus system validate the proposed scheme. The execution time of the proposed scheme in the lab implementation setup adheres to the timeline of the Breaker Failure Protection scheme.

22 November 2021 in Electronics
Verified
Journal Article
Open access
PDF file
PSPrasad Shrawane
Prasad Shrawane
TSTarlochan Sidhu
Tarlochan Sidhu
A large increase in distributed generation integrated within power system networks has resulted in power quality challenges and in the need to resolve complex system faults. The monitoring of the real-time state of the power parameters of the transmission and distribution grid helps to control the stability and reliability of the grid. In such a scenario, having current monitoring equipment that is flexible and easy to install can always be of great help to reduce the price of energy monitoring and to increase the dependability of a smart grid. Advances in magnetic sensor research offer measurement system accuracy that is less complex to install and that can be obtained at a lower less cost. Tunneling magnetoresistive (TMR) sensors can be used to measure the AC current by sensing the magnetic field that is generated by the current-carrying conductor in a contactless manner. This paper illustrates the results of a thorough investigation of factors that can influence the performance of the TMR sensors that are used for the current phasor measurements of a single-phase AC current application, such as the effects of distance, harmonics, and conductor insulation.

30 December 2002
Verified
Conference Paper
Closed access
TSTarlochan Sidhu
Tarlochan Sidhu
HSH. Singh
H. Singh
MSManoj Sachdev
Manoj Sachdev
This paper describes a directional discriminator that uses an artificial neural network (ANN) for protecting transmission lines. The proposed discriminator uses various attributes to reach a decision and tends to emulate the conventional pattern classification problem. An equation of the boundary describing such a classification is embedded in the multilayer feedforward neural network (MFNN) by training through the use of an appropriate learning algorithm and suitable training data. The discriminator uses instantaneous values of voltage and current signals to reach a decision. Simulation results showing the performance of the ANN-based discriminator are presented.<>