Francesca Avella

Ms. Francesca Avella

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2021 in Heritage
Verified
Journal Article
Open access
PDF file
FAFrancesca Avella
Francesca Avella
AGAkshit Gupta
Akshit Gupta
CPClara Peretti
Clara Peretti
GFGianmaria Fulici
Gianmaria Fulici
LVLuca Verdi
Luca Verdi
Francesco BabichFrancesco Babich
Francesco Babich
Children spend a large part of their growing years in schools, and as they are more sensitive to some pollutants than adults, it is essential to monitor and maximize the indoor air quality (IAQ) in classrooms. Many schools are located in historic and heritage buildings, and improving the IAQ, preserving the architectural features, poses a great challenge. The aim of the study is to evaluate the effectiveness of a low-invasiveness, low-cost, smart CO2-based visual alerting systems to manage natural ventilation and improve IAQ in historic school buildings. Indoor and outdoor parameters were monitored for three weeks in four schools with different levels of education (two classrooms per school; device installed in one only). Based on indoor CO2 concentration, air temperature and relative humidity, the device suggests when windows should be opened to ventilate. The comparison between the two classrooms show that the effectiveness of the device is highly dependent on the occupants: (i) reduction in the average CO2 concentrations of up to 42% in classrooms with frontal lesson and full occupancy, (ii) the device is not the most ideal solution for kindergarten due to the young age of the pupils, and (iii) it is more used during mild outdoor temperatures.

15 January 2020 in Atmosphere
Verified
Journal Article
Open access
PDF file
Francesco BabichFrancesco Babich
Francesco Babich
IDIngrid Demanega
Ingrid Demanega
FAFrancesca Avella
Francesca Avella
ABAnnamaria Belleri
Annamaria Belleri
Nowadays, people spend an average of 87% of their time inside buildings, and about 69% at home. Hence, it is essential to ensure the highest possible level of indoor air quality (IAQ). Providing that the quality of the outdoor air is acceptable, the IAQ level is improved by increasing the ventilation rates. However, this means that a larger volume of air must be cooled down or warmed up to ensure the same level of thermal comfort. The aim of this study was to conduct a cost–benefit analysis of the IAQ in residential buildings. A case-study building was defined, and three sets of materials with different pollution emission levels were chosen: High, low, and very low. For each option, the ventilation rates required to have the same IAQ level were calculated, and the consequent energy consumption and costs were estimated by means of dynamic thermal simulation. The results show the range of the initial capital cost that could be compensated for by lower running costs, and the effect of each energy and economic input assumption on the appraisal of the affordable capital cost. In the discussion, insights into the IAQ co-benefits are also given.

1 October 2021 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
FAFrancesca Avella
Francesca Avella
GAG Akshit
G Akshit
ABA Belleri
A Belleri
FBF Babich
F Babich
CPC Peretti
C Peretti
LVL Verdi
L Verdi
Children spend a large part of their growing years in schools, so it is essential to monitor and maximize the indoor air quality (IAQ) of the classrooms. In South Tyrol (northern Italy) many schools are characterised as historic and heritage buildings and improving IAQ poses a great challenge because of the need to maintain the integrity of the architectural characteristics of the structure. The aim of this paper is to provide insights into the effectiveness of a commercial low-cost smart CO2-based visual alerting system used to improve IAQ in an urban kindergarten located in a historic building. Air temperature, relative humidity, along with indoor and outdoor air pollutants, were monitored in a classroom of 22 occupants before and after installation of the passive system. Based on high indoor CO2 concentration and other parameters, the device alerts when to open the windows to facilitate air exchange. This research focuses on the measurements during the first few weeks after installation of the smart device. It did not show a considerable decrease in the CO2 levels, but an improvement is desirable as the occupants become more familiar with the device. This will allow heritage buildings to guarantee a healthier environment in a simple and low-cost way.