Ingrid Demanega

Mrs. Ingrid Demanega

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Building and Environment
Verified
Journal Article
Open access
IDIngrid Demanega
Ingrid Demanega
IMIgor Mujan
Igor Mujan
BSBrett Singer
Brett Singer
AAAleksandar S. Anđelković
Aleksandar S. Anđelković
Francesco BabichFrancesco Babich
Francesco Babich
Dusan LicinaDusan Licina
Dusan Licina

15 January 2020 in Atmosphere
Verified
Journal Article
Open access
PDF file
Francesco BabichFrancesco Babich
Francesco Babich
IDIngrid Demanega
Ingrid Demanega
FAFrancesca Avella
Francesca Avella
ABAnnamaria Belleri
Annamaria Belleri
Nowadays, people spend an average of 87% of their time inside buildings, and about 69% at home. Hence, it is essential to ensure the highest possible level of indoor air quality (IAQ). Providing that the quality of the outdoor air is acceptable, the IAQ level is improved by increasing the ventilation rates. However, this means that a larger volume of air must be cooled down or warmed up to ensure the same level of thermal comfort. The aim of this study was to conduct a cost–benefit analysis of the IAQ in residential buildings. A case-study building was defined, and three sets of materials with different pollution emission levels were chosen: High, low, and very low. For each option, the ventilation rates required to have the same IAQ level were calculated, and the consequent energy consumption and costs were estimated by means of dynamic thermal simulation. The results show the range of the initial capital cost that could be compensated for by lower running costs, and the effect of each energy and economic input assumption on the appraisal of the affordable capital cost. In the discussion, insights into the IAQ co-benefits are also given.

12 April 2022 in Journal of Building Physics
Verified
Journal Article
Closed access
FSFrancesco Squadroni
Francesco Squadroni
GMGiuseppe De Michele
Giuseppe De Michele
EMEnrico Sergio Mazzucchelli
Enrico Sergio Mazzucchelli
IDIngrid Demanega
Ingrid Demanega
SMSara Mangialardo
Sara Mangialardo
SAStefano Avesani
Stefano Avesani
This paper presents a study of the thermo-hygrometric behaviour of a Double Skin Façade (DSF) unit. The study aims (i) at comparing currently used calculation procedures according to European and American standards (UNI EN ISO 10077, UNI EN ISO 12631:2018, ISO 15099:2003, ANSI/NFRC 100 for the thermal performance and ISO 13788:2012 (2012) for the condensation risk), and (ii) at assessing the 2D hygrothermal performance of a double skin module through a Finite Element Method (FEM)-based model. According to the current standards, a detailed characterization of thermal and fluid dynamic phenomena in closed and ventilated cavities is neglected and a simplified approach is proposed, which tends to overestimate the overall U-value of the curtain wall (UCW) due to an incremental thermal resistance that depends on the thickness of the air gap layer and the level of ventilation. The potential risk of this simplification is that the DSF estimated design performance, whilst complying with regulatory requirements, present inconsistencies respect to the real behaviour, impacting energy, comfort, material degradation, etc. Accurate assessments could be done already during design through detailed FEM multi-physic analyses. Nevertheless, those require a specific knowledge, are cost and time-consuming. As a first step, this study focuses on comparing the normed calculation approach for the design, against a detailed FEM-based multi-physics methodology. Specifically, this couples CFD, hygrothermal and Ray Tracing physics in a tool for the calculation of thermal transmittance, g-value and relative humidity of a DSF with a customizable geometry. As a second step, given a real DSF unit that showed unforeseen phenomena of surface condensation inside the cavity during several hours in spring and autumn, the multi-physic tool has been used to evaluate the condensation risk with the current and modified DSF design, under static and time-dependent boundary conditions.

19 February 2023 in Journal of Building Engineering
Verified
Journal Article
Open access
IDIngrid Demanega
Ingrid Demanega
GMGiuseppe De Michele
Giuseppe De Michele
GPGiovanni Pernigotto
Giovanni Pernigotto
AGAndrea Gasparella
Andrea Gasparella
SAStefano Avesani
Stefano Avesani

1 October 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
IDIngrid Demanega
Ingrid Demanega
FIFrancesco Isaia
Francesco Isaia
GMGiordano Miori
Giordano Miori
MJMiren Juaristi
Miren Juaristi
Closed-loop active insulation systems can modulate heat transfer through opaque building envelopes by coupling insulation with controlled internal airflow. By responding to changing environmental conditions, these systems can exploit favourable thermal conditions to support reduced heating and cooling demand in high-performance and net-zero buildings. However, their development is hindered by the lack of systematic methodologies combining full-scale experimental characterisation with validated thermo-fluid modelling. This paper presents an integrated experimental and numerical methodology for the development and validation of a closed-loop active insulation system based on bio-based polyurethane (BioPUR). The investigated component consists of a full-scale insulation panel with embedded air channels and axial fans, designed to switch between insulating and heat-exchanging states. Parametric numerical analysis supported prototype design, followed by experimental characterization in a guarded hot-box facility under controlled steady-state boundary conditions representative of U-value and cooling-demand night scenarios. A three-dimensional conjugate heat-transfer and fluid-flow model was developed in COMSOL Multiphysics and validated against measured surface temperatures and heat fluxes using uncertainty-normalised validation metrics. The system achieved significant thermal adaptation, with measured overall U-values rising from 0.17 to 0.58 Wm-2K-1 (adaptation ratio of 3.4) in the most effective fan configuration. The model accurately reproduces passive and single-fan operation, providing a reliable basis for predicting component behaviour. The validated framework supports design optimisation and future building-scale integration of adaptive envelope technologies, enabling exploration of alternative geometries, airflow configurations, and material choices towards responsive, high-performance building envelopes supporting the transition to net-zero carbon buildings.

17 March 2026 in Buildings
Verified
Journal Article
Open access
PDF file
BMBarbara Messner
Barbara Messner
MGMartino Gubert
Martino Gubert
DTDiego Tamburrini
Diego Tamburrini
SAStefano Avesani
Stefano Avesani
GPGiovanni Pernigotto
Giovanni Pernigotto
IDIngrid Demanega
Ingrid Demanega
The built environment in the EU accounts for 40% of the total energy consumption and 36% of the total greenhouse gas emissions. To address the inefficiency of existing buildings, renovation could reduce their total energy consumption by 5–6% and lower carbon dioxide emissions by approximately 5%. A retrofit solution for existing buildings involves the use of lightweight prefabricated systems, some of which include integrated HVAC components that are able to enhance their functionality. Indeed, such prefabricated facade elements with integrated HVAC systems can represent a minimally invasive method for reducing the energy consumption of an existing building. To assess the potential of this approach, a full-scale mock-up of a prefabricated timber facade with integrated HVAC system was tested at the Facade System Interactions Lab (FSIL) of Eurac Research, Bolzano. The experimental data were used to develop a calibrated and validated 3D finite element model in COMSOL Multiphysics. The validated model was used to evaluate the facade’s thermal performance under standard heating conditions through a proposed equivalent thermal transmittance indicator (Ueq). Results show that the active facade achieves 0.07 W m−2 K−1, compared to 0.21 W m−2 K−1 for the passive facade with identical materials but without active components.