Jeroen Kalkman

Dr. Jeroen Kalkman

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2021 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
Vinoth BalasubramaniVinoth Balasubramani
Vinoth Balasubramani
Malgorzata KujawinskaMalgorzata Kujawinska
Malgorzata Kujawinska
CACédric Allier
Cédric Allier
VIJAYAKUMAR ANANDVIJAYAKUMAR ANAND
VIJAYAKUMAR ANAND
Chau-Jern ChengChau-Jern Cheng
Chau-Jern Cheng
MZMichał Ziemczonok
Michał Ziemczonok
Quantitative Phase Imaging (QPI) provides unique means for the imaging of biological or technical microstructures, merging beneficial features identified with microscopy, interferometry, holography, and numerical computations. This roadmap article reviews several digital holography-based QPI approaches developed by prominent research groups. It also briefly discusses the present and future perspectives of 2D and 3D QPI research based on digital holographic microscopy, holographic tomography, and their applications.

18 November 2013 in Optics Express
Verified
Journal Article
Closed access
PDF file
VNV. Duc Nguyen
V. Duc Nguyen
Dirk FaberDirk Faber
Dirk Faber
EPE. van der Pol
E. van der Pol
TLTon van Leeuwen
Ton van Leeuwen
JKJeroen Kalkman
Jeroen Kalkman
We use transmission and backscattering optical coherence tomography (OCT) to distinguish and quantify dependent and multiple scattering effects in turbid media. With transmission OCT the dependent scattering coefficients for a range of monodisperse silica particle suspensions are determined. An excellent agreement is observed between the measured dependent scattering coefficients and calculations based on Mie calculations, the Percus-Yevick radial distribution function, and coherent light scattering theory. Backscattering OCT measurements are fitted using the extended Huygens-Fresnel (EHF) model with the dependent scattering coefficients obtained from the transmission OCT measurements as input parameters. Good agreement between the EHF model and the backscattering OCT measurements is observed. For large particles, the rms scattering angle θrms obtained from the EHF fit is in fair agreement with θrms calculated from the transmission OCT data.

1 January 2011 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
CPChetan A. Patil
Chetan A. Patil
JKJeroen Kalkman
Jeroen Kalkman
Dirk FaberDirk Faber
Dirk Faber
JNJeffry S. Nyman
Jeffry S. Nyman
TLTon van Leeuwen
Ton van Leeuwen
AMAnita Mahadevan-Jansen
Anita Mahadevan-Jansen
Raman spectroscopy (RS) and optical coherence tomography (OCT) are powerful tools for optical analysis of tissues with mutually complementary strengths and limitations. OCT excels at visualizing tissue microstructure but lacks molecular specificity, while RS can relay tissue biochemical composition but typically cannot relate microstructure. Previous implementations of combined RS-OCT have utilized a common sample arm while maintaining independent RS and OCT detection arms. We present the design and application of an integrated RS-OCT instrument with a common detection arm for both RS and OCT. The detector is a spectrograph capable of sequential detection of the 855-nm OCT signal and the Raman scatter generated by a 785-nm source. The capabilities of the instrument are demonstrated ex vivo in the calvaria and retina of rodents, as well as in vivo in human skin.

13 October 2011 in IEEE Journal of Selected Topics in Quantum Electronics
Verified
Journal Article
Closed access
BAB. Imran Akca
B. Imran Akca
KWKerstin Worhoff
Kerstin Worhoff
RRRene M. de Ridder
Rene M. de Ridder
VNVan Duc Nguyen
Van Duc Nguyen
JKJeroen Kalkman
Jeroen Kalkman
MPMarkus Pollnau
Markus Pollnau
We present experimental results of a spectral-domain optical coherence tomography system based on an integrated optical spectrometer. A 195-channel arrayed-waveguide-grating (AWG) spectrometer with 0.4-nm channel spacing centered at 1300 nm and a 125-channel AWG with 0.16-nm channel spacing centered at 800 nm have been fabricated in silicon oxynitride waveguide technology. Interferometric distance measurements have been performed by launching light from a broadband source into a free-space Michelson interferometer, with its output coupled into the AWG. A maximum imaging depth of 1 mm and axial resolution of 25 and 20 μm in air are demonstrated for the 800- and 1300-nm ranges, respectively.

22 March 2017 in International Journal of Optics
Verified
Journal Article
Open access
PDF file
JKJeroen Kalkman
Jeroen Kalkman
In this work the theory of the optical coherence tomography (OCT) signal after sampling, in dispersive media, with noise, and for a turbid medium is presented. The analytical theory is demonstrated with a one-dimensional numerical OCT model for (single) reflectors, dispersive media, and turbid media. For dispersive media the deterioration of the OCT axial resolution is quantified analytically and numerically. The OCT signal to noise ratio (SNR) is analyzed in the Fourier-domain and simulated with the numerical model. For an SNR based on the OCT intensity the conventional shot noise limited SNR is derived whereas for an SNR based on the OCT amplitude a 6.7 dB higher SNR is demonstrated. The OCT phase stability is derived in the Fourier-domain as 2SNR−1 and is validated using the numerical OCT model. The OCT single scattering model is simulated with the one-dimensional numerical model and applied to the simulation of an OCT image of a two-layered sample.

16 November 2020 in Applied Optics
Verified
Journal Article
Closed access
JWJos de Wit
Jos de Wit
STSebastian Tonn
Sebastian Tonn
GAGuido Van Den Ackerveken
Guido Van Den Ackerveken
JKJeroen Kalkman
Jeroen Kalkman
Optical coherence tomography (OCT) can be a valuable imaging tool for in vivo and label-free digital plant phenotyping. However, for imaging leaves, air-filled cavities limit the penetration depth and reduce the image quality. Moreover, up to now quantification of leaf morphology with OCT has been done in one-dimensional or two-dimensional images only, and has often been limited to relative measurements. In this paper, we demonstrate a significant increase in OCT imaging depth and image quality by infiltrating the leaf air spaces with water. In the obtained high-quality OCT images the top and bottom surface of the leaf are digitally segmented. Moreover, high-quality en face images of the leaf are obtained from numerically flattened leaves. Segmentation in three-dimensional OCT images is used to quantify the spatially resolved leaf thickness. Based on a segmented leaf image, the refractive index of an infiltrated leaf is measured to be , deviating only 1.2% from that of pure water. Using the refractive index and a correction for refraction effects at the air-leaf interface, we quantitatively mapped the leaf thickness. The results show that OCT is an efficient and promising technique for quantitative phenotyping on leaf and tissue level.