The utilization of power converters in a distribution network could give rise to stability problems, especially when the penetration is high. The existing literature studies the modeling and stability of converters with specific control or synchronization methods. However, the types or the control schemes of converters are normally different in an actual grid, and moreover the line impedance plays an important role on the network stability. In this regard, this paper aims at studying the modeling and stability issues of a two-bus electric network with both grid-forming and grid-following converters. The main purpose is to provide design guidelines and solution of two-bus system with converters for stable operation. The interactions between the converters in various scenarios will be investigated by considering the effect of line impedance. More importantly, a filter-based stabilized control strategy will be proposed for the grid-forming converters to mitigate the oscillation in the network. Simulation and experimental results are provided to validate the effectiveness of the theoretical analysis and control strategy.
27 March 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
In this paper, a deadbeat predictive current control based fault-tolerant scheme is proposed and developed for dual three-phase PMSM drives. For open-phase fault of dualthree phase PMSM, the current references are derived without low-order components for minimum stator copper loss. The utilization of deadbeat predictive current control guarantees high control bandwidth for the current references under faulttolerant operation. Then, a fault-tolerant control scheme is proposed for open-switch fault based on hybrid current references, which can fully utilize the remaining one health switch in the faulty inverter leg and minimize the stator copper loss. The additional copper loss caused by the open-switch fault can be reduced by around half with the proposed fault-tolerant control compared to previous remedial strategies. Thus, the ultimate torque output under open-switch fault can be increased by around 20%. The machine model, the space vector diagram, and the control structure of motor systems remain unchanged with the proposed fault-tolerant control scheme. The validity of the proposed fault-tolerant control schemes is verified by experiments.
4 September 2019 in IEEE Transactions on Energy Conversion
Grid converters need a synchronization which is often a phase-locked loop (PLL) to get connected to the grid. In the literature, impedance-based models using small-signal technique have been widely utilized to describe the behaviors of PLL-synchronized grid converter. However, most of them target at specific problems and are able to represent the phenomenon under certain scenarios. For the analysis during phase transient, like phase jump due to grid fault, an accurate model is still missing. To address this issue, a general impedance-based model using Maclaurin expansions for its trigonometric function approximation has been proposed in this paper, so that it can well represent the system behavior during phase transient. Moreover, different deepness of the general model can be scaled, leading to different models including phasorial model, current source model, impedance-based model with/without PLL effects. A guideline on how to choose a proper model based on the problems to be studied and grid conditions has been provided in this paper. Simulation and experimental results are given to validate the effectiveness of the model and the theoretical analysis.
1 December 2021 in IEEE Transactions on Power Electronics
The dc distribution power system has drawn widespread attention and rapidly developed in recent years; however, its stability issue is one of the urgent challenges, requiring much attention. In previous stability studies, the line impedance network is often overlooked, which is convenient for the geographically centralized systems, but inaccurate for the distributed systems. In this article, the modeling and stability criteria of these two systems are simultaneously studied. For the distributed systems, first, the transfer functions from each input voltage or current disturbance to the bus voltage are derived. On this basis, the sufficient and necessary condition for the system stability is discussed. Subsequently, a bus node impedance criterion (BNIC) is proposed to assess the small-signal stability of the dc distribution power system. For the centralized systems, by ignoring the line impedance network, its small-signal model can be deduced by the distributed system, and the proposed BNIC is proved to be still valid. In addition, some existing impedance-based stability criteria are analyzed and compared with the proposed BNIC. Finally, the correctness and effectiveness of the proposed BNIC are verified by the cases study and experiments.
29 August 2024 in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
The increasing prevalence of grid-following (GFL) converters in modern power systems raises concerns about transient stability, mainly stemming from loss of synchronization (LOS). In certain scenarios, grid-forming (GFM) converters are utilized to improve system stability. Existing literature focuses on the transient stability analysis of individual converter types, with limited attention given to hybrid systems incorporating both GFL and GFM converters. Particularly, the interactions between these converter types, concerning transient stability, are seldom discussed, and stability enhancement in such systems remains unexplored. To address this gap, this paper aims to investigate the interaction mechanism of paralleled GFL and GFM converters and propose a control strategy to mitigate the risk of LOS in hybrid systems. The paper presents detailed aggregated models, theoretical analysis, and the control design of the proposed scheme. Theoretical analyses and the proposed method are validated through simulation and experimental results
31 January 2018 in IEEE Transactions on Power Electronics
Parallel inverters are commonly adopted in high-power applications, for instance wind energy systems, smart transformers, and power conditioners. Meanwhile, interleaved pulse width modulation is usually considered as an optimal approach to reduce the current ripple and harmonics of the parallel inverters. However, in the case of a common dc link, the problem of circulating current emerges and leads to performance degradation. This paper aims at investigating the influence of different modulation techniques on the circulating current of two neutral-point-clamped (NPC) inverters under interleaved operation. Two modulation techniques, phase disposition (PD) and alternative phase opposite disposition (APOD), have been studied and compared in terms of current ripple, spectrum quality, and circulating current. Though the PD modulation was regarded as the optimum solution in most of the single-NPC cases, it offers worse performance in the two parallel NPC applications due to higher circulating current. Simulation and experimental validations are provided and show that the APOD leads to much lower circulating current and similar current ripple as well as spectrum quality compared to the PD.