Xinbo Ruan

Xinbo Ruan

Auto-generated profile, based on publicly available information

Xinbo Ruan

Nanjing University of Aeronautics and Astronautics

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
LZLi Zhang
Li Zhang
XRXinbo Ruan
Xinbo Ruan
The instantaneous input and output power of twostage single-phase converter are imbalanced, resulting in the second harmonic current (SHC) in the dc-dc converter, dc source or dc load. This paper revisits the SHC reduction control schemes from the dc-bus port-impedance perspective. The dc-dc converters in two-stage single-phase converters are categorized into two types, namely, bus-voltage-controlled converter (BVCC) and bus-currentcontrolled converter (BCCC). The dc-bus port-impedance of the BVCC is revealed to be approximately inversely proportional to the voltage loop gain. Thus, for reducing the SHC in the BVCC, advanced control schemes are required for increasing the dc-bus port-impedance. The dc-bus port-impedance of the BCCC is proved to be a negative resistor within the control bandwidth. Hence, for reducing the SHC in the BCCC, the dc bus voltage ripple should be limited. From the dc-bus port-impedance perspective, the SHC reduction control schemes are reclassified into closed-loop-design-based, virtual-impedance-based, and power-decoupling-based approaches, based on which, different SHC reduction control schemes are carefully reviewed and compared. Finally, potential challenges and issues are discussed.

17 November 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
GWGang Wu
Gang Wu
XRXinbo Ruan
Xinbo Ruan
ZYZhihong Ye
Zhihong Ye
Due to the relatively low output voltage of photovoltaic (PV) source, a high step-up converter with high efficiency is needed when the PV source is connected to the power grid. A novel high step-up converter based on two switched capacitors and a coupled inductor is proposed in this paper. The operating principle is analyzed and the voltage gain is derived. A 100-W prototype is fabricated in the laboratory to verify the theoretical analysis, and the highest efficiency is 96.4%.

3 April 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DMDajun Ma
Dajun Ma
WU CHENWU CHEN
WU CHEN
XRXinbo Ruan
Xinbo Ruan
Recently more occasions with high input voltage and/or high output voltage applications are emerging. However, the existing switching devices are limited by the voltage stress, e.g., the available maximum blocking voltage of IGBTs is 6.5 kV. Therefore, several methods are provided to solve this issue, including series connection of switches, multilevel converters and modular series-parallel structures, where the modular series-parallel systems are the most popular choice due to the advantages of low cost, simple design process, high modularity, reliability and redundancy. The main issue of series-parallel systems is to ensure the sharing of input/output voltage/current. Based on this, this paper provides a comprehensive review on the available voltage/current sharing methods for series-parallel systems, which include input-series output-parallel (ISOP), input-parallel output-series (IPOS), and input-series output-series (ISOS) structures. Moreover, the relationships between the input voltage/current sharing and output voltage/current sharing of series-parallel systems are explained.

15 January 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
LJLei Jia
Lei Jia
XRXinbo Ruan
Xinbo Ruan
WZWenxin Zhao
Wenxin Zhao
ZLZhiheng Lin
Zhiheng Lin
XWXuehua Wang
Xuehua Wang
When a grid-connected inverter is connected to a weak grid, the system may be instable. An active damper can be connected to the point of common coupling (PCC), which simulates a virtual resistor to damp the resonance and thus stabilize the system. In this paper, an adaptive tuning method of the virtual resistor is proposed, which can automatically regulate the virtual resistor to the critical value to stabilize the system, and thus reduce the power loss. Furthermore, the active damper is designed not to respond to the dominant low-frequency harmonic components in the PCC voltage introduced by the grid background harmonics, so that its power loss can be further reduced. In order to make the active damper more accurately simulate the virtual resistor in a wide frequency range, a harmonic-current-reference compensation method is proposed. The prototypes of a 6-kW grid-connected inverter and a 1-kVA active damper are built and tested to verify the effectiveness of the proposed control scheme of the active damper.

30 August 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
LZLi Zhang
Li Zhang
XRXinbo Ruan
Xinbo Ruan
XRXiaoyong Ren
Xiaoyong Ren
The instantaneous output power of the two-stage single-phase inverter pulsates at twice the output frequency (2f o ), generating notorious second-harmonic current (SHC) in the frontend dc-dc converter and the input dc voltage source. This paper focuses on the SHC reduction for a two-stage single-phase inverter with boost-derived front-end converter. To reduce the SHC, a virtual series impedance, which has high impedance at 2f o while low impedance at other frequencies, is introduced in series with the boost diode or the boost inductor to increase the impedance of the boost-diode branch or boost-inductor branch at 2f o . Meanwhile, for achieving good dynamic performance, a virtual parallel impedance, which exhibits infinite impedance at 2f o while low impedance at other frequencies, is introduced in parallel with the dc-bus capacitor to reduce the output impedance of the boost-derived converter at the frequencies except for 2f o . The virtual series impedance is realized by the feedback of the boost-diode current or the boost-inductor current, while the virtual parallel impedance is implemented by the feedback of the dc-bus voltage. Based on the virtual-impedance approach, a variety of SHC reduction control schemes are derived. A step-by-step closed-loop parameters design approach with considerations of reducing the SHC and improving the dynamic performance is also proposed for the derived SHC reduction control schemes. Finally, a 1-kW prototype is built and tested, and experimental results are presented to verify the effectiveness of the proposed SHC reduction control schemes.

19 March 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YHYuying He
Yuying He
XWXuehua Wang
Xuehua Wang
XRXinbo Ruan
Xinbo Ruan
DPDonghua Pan
Donghua Pan
XXXingping Xu
Xingping Xu
FLFuxin Liu
Fuxin Liu
Capacitor-current-feedback active damping has been widely used in LCL-type grid-connected inverters. However, the damping performance is deteriorated due to the negative equivalent resistance resulted by the digital control delays, and thus the grid-connected inverter is apt to be unstable under the grid impedance variation. To address this issue, this paper proposes the capacitor-current proportional-integral (PI) positive feedback active damping method, which can ensure a positive equivalent resistance almost within the Nyquist frequency, i.e., the full controllable frequency range. In theory, the proposed damping method can be implemented by feeding back the capacitor current through a PI function. However, the integral term will continuously accumulate the noise and dc bias arising from the feedback signal. To overcome this drawback, a more practical implementation solution is drawn in this paper. Furthermore, a straightforward design procedure is presented for the convenience of selecting the proper controller parameters. With the proposed damping method and its practical implementation, high inverter robustness against the grid impedance variation can be achieved. Experiments are performed on a 6-kW prototype and the experimental results are in well agreement with the theoretical expectations.