HAORAN JI

Prof. Dr. HAORAN JI

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2018 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
HAORAN JIHAORAN JI
HAORAN JI
CWChengshan Wang
Chengshan Wang
Peng LiPeng Li
Peng Li
FDFei Ding
Fei Ding
JWJianzhong Wu
Jianzhong Wu
Distributed generators (DGs) including photovoltaic panels (PVs) have been integrated dramatically in active distribution networks (ADNs). Due to the strong volatility and uncertainty, the high penetration of PV generation immensely exacerbates the conditions of voltage violation in ADNs. However, the emerging flexible interconnection technology based on soft open points (SOPs) provides increased controllability and flexibility to the system operation. For fully exploiting the regulation ability of SOPs to address the problems caused by PV, this paper proposes a robust optimization method to achieve the robust optimal operation of SOPs in ADNs. A two-stage adjustable robust optimization model is built to tackle the uncertainties of PV outputs, in which robust operation strategies of SOPs are generated to eliminate the voltage violations and reduce the power losses of ADNs. A column-and-constraint generation (C&CG) algorithm is developed to solve the proposed robust optimization model, which are formulated as second-order cone program (SOCP) to facilitate the accuracy and computation efficiency. Case studies on the modified IEEE 33-node system and comparisons with the deterministic optimization approach are conducted to verify the effectiveness and robustness of the proposed method.

15 August 2017 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
Peng LiPeng Li
Peng Li
HAORAN JIHAORAN JI
HAORAN JI
CWChengshan Wang
Chengshan Wang
JZJinli Zhao
Jinli Zhao
GSGuanyu Song
Guanyu Song
JWJianzhong Wu
Jianzhong Wu
The asymmetric integration of distributed generators (DGs) exacerbates the three-phase unbalanced condition in distribution systems. The serious unbalanced operation causes inefficient utilization of network assets and security risks in the system. Soft open point (SOP) is a flexible power electronic device which can achieve accurate active and reactive power flow control to balance the power flow among phases. This paper proposes an SOPs-based operation strategy for unbalanced active distribution networks. By regulating the operation of SOPs, the strategy can reduce power losses and simultaneously mitigate the three-phase unbalance of the upper-level grid. Semidefinite programming (SDP) relaxation is advocated to convert the original non-convex, nonlinear optimization model into an SDP formulation, which can be efficiently solved to meet the requirement of rapid adjustment. Case studies are conducted on the modified IEEE 33-node and IEEE 123-node distribution system to verify the effectiveness and efficiency of the proposed strategy.

17 March 2020 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
Peng LiPeng Li
Peng Li
JJJie Ji
Jie Ji
HAORAN JIHAORAN JI
HAORAN JI
JJJie Jian
Jie Jian
FDFei Ding
Fei Ding
CWChengshan Wang
Chengshan Wang
The increasing penetration of distributed generators (DGs) exacerbates the voltage violations in active distribution networks (ADNs). The commonly used centralized voltage control may aggravate the burden of computation and communication. Local voltage control can realize fast response to frequent voltage fluctuations. However, effective local control for DGs still needs to be further investigated. In this paper, a model predictive control (MPC)-based local voltage control strategy of DGs is proposed to cope with voltage violation problems and enhance the adaptation to the DG volatility. DGs are regulated with local Q-V control curves to respond to voltage fluctuations rapidly. Based on the dynamic network partition, a unified control curve for DGs is set in the same area to realize efficient operation. To further improve the performance of voltage control, the parameter tuning of control curves is regularly conducted based on decentralized inter-area coordination with the rolling of the control horizon. Finally, the case study is verified on the modified IEEE 33-node distribution system. The proposed local control strategy of DGs can effectively improve the voltage profile and reduce power losses of the whole network without high computation and communication burden.

16 June 2023 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
JJJie Jian
Jie Jian
JZJinli Zhao
Jinli Zhao
HAORAN JIHAORAN JI
HAORAN JI
LBLinquan Bai
Linquan Bai
JXJing Xu
Jing Xu
CWChengshan Wang
Chengshan Wang
The reliable operation of Internet data centers (IDCs) is crucial to digitization transformation of society. However, the extreme fault on the IDC-located distribution network is fatal to IDC operation. The evolution of flexible distribution networks (FDNs) can satisfy the deep dependence of IDC on high-quality and reliable power supply. In FDNs, AC/DC feeders with multiple voltage levels can be flexibly interconnected and adjusted by flexible stations (FSs). It is promising to flexibly enhance operation performance of crucial IDCs after fault isolation in FDNs. In this paper, a coordinated supply restoration method of IDCs in FDNs with spatial-temporal regulation is proposed to minimize IDC data-dropping loss under complex faults. First, a spatial-temporal transfer strategy of IDC workloads is precisely formulated and an FS-based network reconfiguration strategy is proposed. Then, a mixed-integer second-order conic programming model is established for efficient solving. Spatial-temporal coordination among the source, network, storage, and demand sides can be realized without violating physical feasibility. Finally, the proposed method is validated on the modified IEEE 33-node and modified IEEE 123-node test cases. Case studies show that total outage loss is effectively reduced with sufficient utilization of available power. Operational performance of FDN is also enhanced under extreme faults.

5 May 2022 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
YHYanda Huo
Yanda Huo
Peng LiPeng Li
Peng Li
HAORAN JIHAORAN JI
HAORAN JI
HYHao Yu
Hao Yu
JYJinyue Yan
Jinyue Yan
CWChengshan Wang
Chengshan Wang
The highly penetrated distributed generators (DGs) aggravate the voltage violations in active distribution networks (ADNs). The coordination of various regulation devices such as on-load tap changers (OLTCs) and DG inverters can effectively address the voltage issues. Considering the problems of inaccurate network parameters and rapid DG fluctuation in practical operation, multi-source data can be utilized to establish the data-driven control model. In this paper, a data-driven coordinated voltage control method with the coordination of OLTC and DG inverters on multiple time-scales is proposed without relying on the accurate physical model. First, based on the multi-source data, a data-driven voltage control model is established. Multiple regulation devices such as OLTC and DG are coordinated on multiple time-scales to maintain voltages within the desired range. Then, a critical measurement selection method is proposed to guarantee the voltage control performance under the partial measurements in practical ADNs. Finally, the proposed method is validated on the modified IEEE 33-node and IEEE 123-node test cases. Case studies illustrate the effectiveness of the proposed method, as well as the adaptability to DG uncertainties.

6 May 2022 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
JZJinli Zhao
Jinli Zhao
ZZZiqi Zhang
Ziqi Zhang
HYHao Yu
Hao Yu
HAORAN JIHAORAN JI
HAORAN JI
Peng LiPeng Li
Peng Li
CWChengshan Wang
Chengshan Wang
The increased distributed generators (DGs) have exacerbated voltage violations in active distribution networks (ADNs). Local reactive power control of DG inverters can realize a fast response to frequent voltage fluctuations. However, commonly used model-based voltage control depends upon accurate network parameters and entire ADN data, which may cause the sensitive information leakage of ADN and DG behaviors in practical operation. In this article, a cloud-edge collaboration-based local voltage control strategy for DGs is proposed with privacy preservation. First, a local voltage control framework is established based on cloud-edge collaboration, in which a surrogate model is built based on the graph convolutional neural networks to estimate the ADN voltages. By transferring the surrogate model, the edge side can obtain the exact voltage estimation in the local curve tuning process without the authority of the whole ADN data, preserving the network parameters of ADN. Then, the interarea coordination based on federated learning is proposed to realize the parameter updating of DG control curves, which can achieve better voltage control performance. By updating surrogate submodels based on private data distributed across multiple edge devices, federated learning can effectively preserve DG behaviors. Finally, the effectiveness and adaptability of the proposed control strategy are validated using the modified IEEE 33-node system. The proposed local DG control strategy can effectively cope with voltage problems and enhance the adaptability to variations in practical operation states while considering privacy preservation.