The propagation of hybrid power systems (solar–diesel–battery) has led to the development of new energy management system (EMS) strategies for the effective management of all power generation technologies related to hybrid microgrids. This paper proposes two novel EMS strategies for isolated hybrid microgrids, highlighting their strengths and weaknesses using simulations. The proposed strategies are different from the EMS strategies reported thus far in the literature because the former enable the real-time operation of the hybrid microgrid, which always guarantees the correct operation of a microgrid. The priority EMS strategy works by assigning a priority order, while the optimal EMS strategy is based on an optimization criterion, which is set as the minimum marginal cost in this case. The results have been obtained using MATLAB/Simulink to verify and compare the effectiveness of the proposed strategies, through a dynamic microgrid model to simulate the conditions of a real-time operation. The differences in the EMS strategies as well as their individual strengths and weaknesses, are presented and discussed. The results show that the proposed EMS strategies can manage the system operation under different scenarios and help power system operator obtain the optimal operation schemes of the microgrid.
The requirements for the increased penetration of renewable energy sources in electrical power systems have led to a dominance of power electronic interfaces. As a result, short-circuit currents have been reduced by the thermal limitations of power electronics, leading to problems associated with the sensitivity, selectivity, and reliability of protective relays. Although many solutions can be found in the literature, these depend on communications and are not reliable in all grid topologies or under different types of electrical fault. Hence, in this paper, the analysis of ground fault currents and voltages using a wavelet transform in combination with a new algorithm not only detects such ground faults but also allows them to be cleared quickly and selectively in scenarios with low fault current contribution due to a full penetration converter-interface-based generation. To verify and validate the proposed protection system, different ground faults are simulated using an arc ground fault model in a grid scheme based on the IEEE nine-bus standard test system, with only grid-forming power converters as generation sources. The test system is modelled in the MATLAB/Simulink environment. Therefore, the protection relays that verify all the steps established in the new algorithm can detect and clear any ground defect. Simulations are also presented involving different fault locations to demonstrate the effectiveness of the proposed ground fault protection method.