Sully Quintero

Dr. Sully Quintero


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2011 in Sensors
Verified
Journal Article
Open access
PDF file
SQSully Quintero
Sully Quintero
CMCicero Martelli
Cicero Martelli
ABArthur M. B. Braga
Arthur M. B. Braga
LVLuiz C. G. Valente
Luiz C. G. Valente
CKCarla C. Kato
Carla C. Kato
A magnetic field sensor based on the integration of a high birefringence photonic crystal fiber and a composite material made of Terfenol particles and an epoxy resin is proposed. An in-fiber modal interferometer is assembled by evenly exciting both eigenemodes of the HiBi fiber. Changes in the cavity length as well as the effective refractive index are induced by exposing the sensor head to magnetic fields. The magnetic field sensor has a sensitivity of 0.006 (nm/mT) over a range from 0 to 300 mT with a resolution about ±1 mT. A fiber Bragg grating magnetic field sensor is also fabricated and employed to characterize the response of Terfenol composite to the magnetic field.

12 December 2018 in Sensors
Verified
Journal Article
Open access
PDF file
SQSully Quintero
Sully Quintero
LVLuiz Carlos Guedes Valente
Luiz Carlos Guedes Valente
MGMarcos Gomes
Marcos Gomes
HSHugo Gomes da Silva
Hugo Gomes da Silva
BSBernardo Caroli de Souza
Bernardo Caroli de Souza
SMSergio R. K. Morikawa
Sergio R. K. Morikawa
A realistic implementation of an all-fiber CO2 sensor, using 74 cm of hollow core photonic crystal fiber (HC-PCF) as the cavity for light/gas interaction, has been implemented. It is based on CO2 absorbance in the 2 µm region. The working range is from 2% to 100% CO2 concentration at 1 atm total pressure and the response time obtained was 10 min. Depending on the concentration level, the sensor operates at one of three different wavelengths (2003.5 nm, 1997.0 nm and 1954.5 nm) to maintain a high sensitivity across all the working range.

15 July 2017 in Sensors
Verified
Journal Article
Open access
PDF file
SQSully Quintero
Sully Quintero
SFSávio Figueiredo
Sávio Figueiredo
VTVictor Takahashi
Victor Takahashi
RLRoberth A. W. Llerena
Roberth A. W. Llerena
ABArthur Braga
Arthur Braga
A passive surface acoustic wave (SAW) pressure sensor was developed for real-time pressure monitoring in downhole application. The passive pressure sensor consists of a SAW resonator, which is attached to a circular metal diaphragm used as a pressure transducer. While the membrane deflects as a function of pressure applied, the frequency response changes due to the variation of the SAW propagation parameters. The sensitivity and linearity of the SAW pressure sensor were measured to be 8.3 kHz/bar and 0.999, respectively. The experimental results were validated with a hybrid analytical–numerical analysis. The good results combined with the robust design and packaging for harsh environment demonstrated it to be a promising sensor for industrial applications.

20 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
VTVictor Takahashi
Victor Takahashi
AKAlan Kubrusly
Alan Kubrusly
ABArthur Braga
Arthur Braga
SQSully Quintero
Sully Quintero
SFSávio W. O. Figueiredo
Sávio W. O. Figueiredo
ADAna B. Domingues
Ana B. Domingues
Ultrasonic power and data transfer through multilayered curved walls was investigated using numerical and experimental analysis. The acoustic channel used in this paper was formed by two concentric pipes filled with water, aiming for applications that involve powering and monitoring sensors installed behind the pipe walls. The analysis was carried out in the frequency and time domains using numerical and experimental models. Power and data were effectively simultaneously transferred through the channel. A remote temperature and pressure sensor was powered and interrogated throughout all the layers, and the power insertion loss was 10.72 dB with a data transmission rate of 1200 bps using an amplitude modulated scheme with Manchester coding. The efficiency of the channel was evaluated through an experimental analysis of the bit error rate (BER) with different values of signal-to-noise ratio (SNR), showing a decrease in the number of errors compared with detection without Manchester coding.

8 August 2019 in Preprints.org
Verified
Preprint
Open access
PDF file
VTVictor Takahashi
Victor Takahashi
AKAlan Kubrusly
Alan Kubrusly
ABArthur Braga
Arthur Braga
SQSully Quintero
Sully Quintero
SFSávio W. O. Figueiredo
Sávio W. O. Figueiredo
ADAna B. Domingues
Ana B. Domingues
Ultrasonic power and data transfer through multilayered curved walls is investigated using numerical and experimental analysis. The acoustic channel used in this paper is formed by two concentric pipes filled with water, aiming for applications that involve powering and monitoring sensors installed behind the pipe walls. The analysis was carried out in the frequency and time domains using numerical and experimental models. Power and data were effectively simultaneously transferred through the channel. A remote temperature and pressure sensor was powered and interrogated throughout all the layers, and the power insertion loss of 10.72dB with a data transmission rate of 1200 bps using an amplitude modulated scheme with Manchester coding. The efficiency of the channel was evaluated through an experimental analysis of bit error rate (BER) with different values of SNR, showing a decreasing in number of errors comparing with the detection without Manchester coding.

31 October 2018 in Preprints.org
Verified
Preprint
Open access
PDF file
SQSully Quintero
Sully Quintero
LVLuiz Carlos Guedes Valente
Luiz Carlos Guedes Valente
MGMarcos Gomes
Marcos Gomes
HSHugo Gomes da Silva
Hugo Gomes da Silva
BSBernardo Caroli de Souza
Bernardo Caroli de Souza
A realistic implementation of an all-fiber CO2 sensor, using 74 cm of hollow core PCF fiber as the cavity for light/gas interaction, has been implemented. It is based on CO2 absorbance in the 2 μm region. The working range is from 2% to 100% CO2 concentration at 1 atm total pressure. The response time obtained was 10 min. The use of an FBG tuned fiber ring laser, specifically designed for this application, is discussed and preliminary results with this laser are also presented.