Cicero Martelli

Prof. Cicero Martelli


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2011 in Sensors
Verified
Journal Article
Open access
PDF file
SQSully Quintero
Sully Quintero
CMCicero Martelli
Cicero Martelli
ABArthur M. B. Braga
Arthur M. B. Braga
LVLuiz C. G. Valente
Luiz C. G. Valente
CKCarla C. Kato
Carla C. Kato
A magnetic field sensor based on the integration of a high birefringence photonic crystal fiber and a composite material made of Terfenol particles and an epoxy resin is proposed. An in-fiber modal interferometer is assembled by evenly exciting both eigenemodes of the HiBi fiber. Changes in the cavity length as well as the effective refractive index are induced by exposing the sensor head to magnetic fields. The magnetic field sensor has a sensitivity of 0.006 (nm/mT) over a range from 0 to 300 mT with a resolution about ±1 mT. A fiber Bragg grating magnetic field sensor is also fabricated and employed to characterize the response of Terfenol composite to the magnetic field.

1 November 2010 in Sensors
Verified
Journal Article
Open access
PDF file
FFFernando Favero
Fernando Favero
SQSully M. M. Quintero
Sully M. M. Quintero
CMCicero Martelli
Cicero Martelli
ABArthur Braga
Arthur Braga
VSVinícius V. Silva
Vinícius V. Silva
LVLuiz C. G. Valente
Luiz C. G. Valente
The effect of hydrostatic pressure on the waveguiding properties of high birefringence photonic crystal fibers (HiBi PCF) is evaluated both numerically and experimentally. A fiber design presenting form birefringence induced by two enlarged holes in the innermost ring defining the fiber core is investigated. Numerical results show that modal sensitivity to the applied pressure depends on the diameters of the holes, and can be tailored by independently varying the sizes of the large or small holes. Numerical and experimental results are compared showing excellent agreement. A hydrostatic pressure sensor is proposed and demonstrated using an in-fiber modal interferometer where the two orthogonally polarized modes of a HiBi PCF generate fringes over the optical spectrum of a broad band source. From the analysis of experimental results, it is concluded that, in principle, an operating limit of 92 MPa in pressure could be achieved with 0.0003% of full scale resolution.

25 December 2019 in IEEE Sensors Letters
Verified
Journal Article
Closed access
ZHZhongyang Hao
Zhongyang Hao
KCKevin Cook
Kevin Cook
JCJohn Canning
John Canning
HCHsiang-Ting Chen
Hsiang-Ting Chen
CMCicero Martelli
Cicero Martelli
This paper reports a 3D printing intelligent insole gait monitoring system based on embedded fiber Bragg grating. The smart insole combines 3D printing technology and fiber Bragg gratings (FBGs) sensors providing high sensitivity and end-point low cost. Results using pressure points measured by four FBGs are sufficient to differentiate foot loads and gait types.

22 December 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JGJosé Rodolfo Galvão
José Rodolfo Galvão
Carlos RuizCarlos Ruiz
Carlos Ruiz
CMCicero Martelli
Cicero Martelli
JSJean Carlos Cardozo Da Silva
Jean Carlos Cardozo Da Silva
FAFrancisco J. Arregui
Francisco J. Arregui
IMIgnacio Matias
Ignacio Matias
This study presents the utilization of optical fiber Bragg gratings (FBGs) embedded into a carbon fiber reinforced polymer transtibial prosthesis to evaluate the user’s gait, as well as its own performance. Static mechanical tests were performed to characterize the sensors. Vertically and horizontally positioned FBGs within the structure have been used for load and strain force evaluation during real-time experiments with a candidate at different speeds on a treadmill. For simplicity, one non-amputee candidate performed the experiments using a mechanical adaptation. Distinctive patterns of response of the FBGs located at different points within the prosthetic structure enabled the differentiation between slow and fast motion gait cycle and the force distribution during the tread. This optical instrumentation contributes to the development of a new tool for the evaluation of prosthesis design and amputee patients rehabilitation and to the assessment of the performance of athletes during training or competition.

17 March 2015 in Sensors
Verified
Journal Article
Open access
PDF file
VBVirginia Baroncini
Virginia Baroncini
CMCicero Martelli
Cicero Martelli
JSJean Carlos Cardozo Da Silva
Jean Carlos Cardozo Da Silva
RMRigoberto E.M. Morales
Rigoberto E.M. Morales
Single- and two-phase flow characterization using optical fiber Bragg gratings (FBGs) is presented. The sensor unit consists of the optical fiber Bragg grating positioned transversely to the flow and fixed in the pipe walls. The hydrodynamic pressure applied by the liquid or air/liquid flow to the optical fiber induces deformation that can be detected by the FBG. Given that the applied pressure is directly related to the mass flow, it is possible to establish a relationship using the grating resonance wavelength shift to determine the mass flow when the flow velocity is well known. For two phase flows of air and liquid, there is a significant change in the force applied to the fiber that accounts for the very distinct densities of these substances. As a consequence, the optical fiber deformation and the correspondent grating wavelength shift as a function of the flow will be very different for an air bubble or a liquid slug, allowing their detection as they flow through the pipe. A quasi-distributed sensing tool with 18 sensors evenly spread along the pipe is developed and characterized, making possible the characterization of the flow, as well as the tracking of the bubbles over a large section of the test bed. Results show good agreement with standard measurement methods and open up plenty of opportunities to both laboratory measurement tools and field applications.

29 August 2012 in Sensors
Verified
Journal Article
Open access
PDF file
MMMaura Milczewski
Maura Milczewski
JSJean Carlos Cardozo Da Silva
Jean Carlos Cardozo Da Silva
CMCicero Martelli
Cicero Martelli
LGLeandro Grabarski
Leandro Grabarski
IAIlda Abe
Ilda Abe
HKHypolito José Kalinowski
Hypolito José Kalinowski
The aim of this work is to show the possibility of using fiber optic sensors to instrument inside parts of an artificial maxilla and measure internal tension transmitted by the orthodontic and orthopedic appliances to the dentition and the adjacent bone. Bragg gratings written in a standard optical fiber were used to monitor the maxillary teeth and a multiplexed fiber was used to monitor the surface of the maxillary bone, transversally to the longest axis of the teeth. A Universal Test Machine was used to evaluate the sensitivity of the sensor to the vertical and lateral forces applied on the teeth. A wavelength shift of approximately 0.30 nm was detected when applying loads ranging from 0 to 20 N. By applying forces using the standard orthodontic appliances installed on the dentition it was possible to detect a range of forces between 0.025 N to 0.035 N during the activation of the arch wire and extra-oral forces. The use of the internal sensors in an artificial model made possible the monitoring of the resulting forces on the internal parts of the teeth and at the position where the strain takes place within the maxilla. The sensors detected that the orthodontic forces were not transmitted to the surface of the maxilla. This information is important to elucidate and to correlate undesirable effects as tooth root absorption and local pain during the orthodontic treatment.