Petra Itterheimová

Mrs. Petra Itterheimová

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2022 in Chemosensors
Verified
Journal Article
Open access
PDF file
PIPetra Itterheimová
Petra Itterheimová
Johan BobackaJohan Bobacka
Johan Bobacka
VŠVladimír Šindelář
Vladimír Šindelář
Přemysl LubalPřemysl Lubal
Přemysl Lubal
Dodecabenzylbambus[6]uril (Bn12BU[6]) is an anion receptor that binds the perchlorate ion the most tightly (stability constant ~1010 M−1) of all anions due to the excellent match between the ion size in relation to the receptor cavity. This new bambusuril compound was used as an ionophore in the ion-selective membrane (ISM) to develop ion selective electrodes (ISEs) for determination of perchlorate concentration utilizing the poly(3,4-ethylenedioxythiophene) (PEDOT) polymer film as a solid-contact material. Variation of the content of Bn12BU[6] and tridodecylmethylammonium chloride (TDMACl) in the plasticized poly(vinyl chloride)-based ISM was also tested. All the prepared solid-contact ISEs and their analytical performance were characterized by potentiometry, cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and chronopotentiometry. The ISEs showed rapid response and a sub-Nernstian slope (~57 mV/decade) during potentiometric measurements in perchlorate solutions in the concentration range from 10−1 to 10−6 M simultaneously with their high stability and sufficient selectivity to other common inorganic anions like bromide, chloride, nitrate and sulphate. The function of the ISE was further verified by analysis of real water samples (lake, sea, and mineral water), which gave accurate and precise results.

22 September 2023 in Analytica Chimica Acta
Verified
Journal Article
Closed access
PIPetra Itterheimová
Petra Itterheimová
PKPetr Kubáň
Petr Kubáň

22 September 2021 in Molecules
Verified
Journal Article
Open access
PDF file
MGMałgorzata Gołąb
Małgorzata Gołąb
MPMartyna Przybyłowska
Martyna Przybyłowska
PKPetr Kubáň
Petr Kubáň
PIPetra Itterheimová
Petra Itterheimová
Michal WozniakiewiczMichal Wozniakiewicz
Michal Wozniakiewicz
A fast method for the determination of tropane alkaloids, using a portable CE instrument with a capacitively coupled contactless conductivity detector (CE-C4D) was developed and validated for determination of atropine and scopolamine in seeds from Solanaceae family plants. Separation was obtained within 5 min, using an optimized background electrolyte consisting of 0.5 M acetic acid with 0.25% (w/v) β-CD. The limit of detection and quantification was 0.5 µg/mL and 1.5 µg/mL, respectively, for both atropine and scopolamine. The developed method was validated with the following parameters—precision (CV): 1.07–2.08%, accuracy of the assay (recovery, RE): 101.0–102.7% and matrix effect (ME): 92.99–94.23%. Moreover, the optimized CE-C4D method was applied to the analysis of plant extracts and pharmaceuticals, proving its applicability and accuracy.

4 August 2022 in Electrophoresis
Verified
Journal Article
Closed access
PIPetra Itterheimová
Petra Itterheimová
VDVěra Dosedělová
Věra Dosedělová
PKPetr Kubáň
Petr Kubáň

3 December 2021 in Separations
Verified
Journal Article
Open access
PDF file
MMMiriam Mala
Miriam Mala
PIPetra Itterheimová
Petra Itterheimová
HLHomola Lukas
Homola Lukas
JVJana Vinohradská
Jana Vinohradská
PKPetr Kubáň
Petr Kubáň
Sweat chloride analysis is one of the important approaches in cystic fibrosis diagnosis. The commonly used Macroduct method to acquire sweat samples is semi-invasive, time consuming and expensive. Furthermore, this method often fails to collect a sufficient amount of sweat in newborns due to the insufficient sweating rate. In this work, we present a novel, simple, 3D-printed sampling device that is used to collect sweat specimens completely noninvasively in less than one minute. The device has a flow-through channel adjacent to the skin surface, through which 500 µL of deionized water is flushed and the spontaneously formed sweat on the skin in the channel area is washed into a plastic vial. The developed skin-wash procedure is a single step operation, is completely noninvasive and it always produces a sweat specimen. The ions from the skin-wash are subsequently analyzed by capillary electrophoresis with contactless conductivity detection and selected ion ratio (Cl−/K+) or ((Cl− + Na+)/K+) is used as a cut-off value to diagnose cystic fibrosis patients with sensitivity and specificity comparable to the conventional Macroduct method.