Daria Shabunina

Ms. Daria Shabunina

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2022 in Fire
Verified
Journal Article
Open access
PDF file
Marina Viktorovna GravitMarina Viktorovna Gravit
Marina Viktorovna Gravit
DSDaria Shabunina
Daria Shabunina
The requirements for the fire resistance of steel structures of oil and gas facilities for transportation and production of hydrocarbons are considered (structures of tankers and offshore platforms). It is found that the requirements for the values of fire resistance of structures under hydrocarbon rather than standard fire conditions are given only for offshore stationary platforms. Experimental studies on the loss of integrity (E) and thermal insulating capacity (I) of steel bulkheads and deck with mineral wool under standard and hydrocarbon fire regimes are presented. Simulation of structure heating was performed, which showed a good correlation with the experimental results (convective heat transfer coefficients for bulkheads of class H: 50 W/m2·K; for bulkheads of class A: 25 W/m2·K). The consumption of mineral slabs and endothermic mat for the H-0 bulkhead is predicted. It is calculated that under a standard fire regime, mineral wool with a density of 80–100 kg/m2 and a thickness of 40 to 85 mm should be used; under a hydrocarbon fire regime, mineral wool with a density above 100 kg/m2 and a thickness of 60–150 mm is required. It is shown that to protect the structures of decks and bulkheads in a hydrocarbon fire regime, it is necessary to use 30–40% more thermal insulation and apply the highest density of fire-retardant material compared to the standard fire regime. Parameters of thermal conductivity and heat capacity of the applied flame retardant in the temperature range from 0 to 1000 °C were clarified.

14 November 2021 in Buildings
Verified
Journal Article
Open access
PDF file
Marina Viktorovna GravitMarina Viktorovna Gravit
Marina Viktorovna Gravit
BKBoris Klementev
Boris Klementev
DSDaria Shabunina
Daria Shabunina
Cases of fire with highly flammable, combustible liquids and combustible gases with high potential heat emission at oil and gas facilities are assumed to develop as a hydrocarbon fire, which is characterized by the temperature rising rapidly up to 1093 ± 56 °C within five minutes from the test start and staying within the same range throughout the test, as well as by overpressure being generated. Although various fireproof coating systems are commonly used to protect steel structures from high temperatures, a combination of fire protection and cryogenic spillage protection, i.e., protection from liquefied natural gas (LNG), is rather an international practice novelty regulated by standards ISO 20088. Thanks to their outstanding features, i.e., ability to sustain chemical and climatic impact, these epoxy-based materials are able to ensure positive fireproof performance for steel structures in the case of potential cryogenic impact. The article discusses tests on steel structures coated with epoxy fireproof compounds, specifically PREGRAD-EP, OGRAX-SKE and Chartek 2218. The test records show the time from the start of cryogenic exposure to the said sample reaching the limit state, as well as the time from the start of heat impact to the sample reaching the limit state in case of hydrocarbon fire temperature.

1 February 2022 in Fire
Verified
Journal Article
Open access
PDF file
Marina Viktorovna GravitMarina Viktorovna Gravit
Marina Viktorovna Gravit
Ekaterina KirikEkaterina Kirik
Ekaterina Kirik
ESEgor Savchenko
Egor Savchenko
TVTat'yana Vitova
Tat'yana Vitova
DSDaria Shabunina
Daria Shabunina
Space-planning decisions of two sports and entertainment arenas with large crowds—the Roman Colosseum (Italy) and the modern Gazprom Arena stadium (St. Petersburg, Russia)— were analyzed to compare the flow of people during evacuation by simulation. It was shown that the space-planning decisions of the Colosseum seem more advantageous compared with the Gazprom Arena in calculation of evacuation time and evacuation organization process: the capacity of the stairs of the Colosseum with a width of 2.8 m is comparable with the capacity of the Gazprom Arena’s stairs (4 m). In the Colosseum the average specific flow is qaverage = 1.14 person/s/m, while in the Gazprom Arena the average specific flow is qaverage = 0.65 (with a march width of 2.6 m) and qaverage = 0.8 person/s/m (with a march width of 4 m). It was found that the Colosseum complies with current standards for on-time evacuation; while modern sports and entertainment arenas are currently designed with additional services, infrastructure, comfort and, in general, high commercialization. The antique arenas are currently being reborn and used for concerts and other public events, so the obtained results have practical significance.

9 May 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Marina Viktorovna GravitMarina Viktorovna Gravit
Marina Viktorovna Gravit
DSDaria Shabunina
Daria Shabunina
SASergey Antonov
Sergey Antonov
ADAndrey Danilov
Andrey Danilov
The problems of the fire safety of oil and gas facilities are particularly relevant due to the increasing complexity of technological processes and production. Experimental studies of steel structures with three different types of plasters are presented to determine the time taken to reach the critical temperature and loss of bearing capacity (R) of the sample, as a result of reaching a rate of deformation growth of more than 10 mm/min and the appearance of the ultimate vertical deformation. The simulation of the heating of steel structures showed a good correlation with the results of the experiment. The consumption of the plaster composition for the steel column was predicted, which allowed a 38% reduction in the consumption of fireproofing. It was found that to obtain the required fire resistance limit, it is necessary to consider the fire regime and apply plaster compositions with a thickness of 30–35 mm, depending on their thermal characteristics. The dependence of thermal conductivity and temperature on density is obtained, showing that the use of plaster compositions with a density of 200 to 600 kg/m3 is optimal to ensure a higher fire resistance limit. It is shown that the values of thermal conductivity of plaster compositions at 1000 °C are higher by 8–10% if the structure is exposed to a hydrocarbon fire regime. It is shown that the values of the heat capacity of plaster compositions at 1000 °C are higher by 10–15% if the structure is exposed to a standard fire regime.

22 October 2021 in Buildings
Verified
Journal Article
Open access
PDF file
Marina Viktorovna GravitMarina Viktorovna Gravit
Marina Viktorovna Gravit
DSDaria Shabunina
Daria Shabunina
Most structures in the Arctic and Antarctic for oil and gas production are offshore stations, tankers, modules, steel supporting, and enclosing structures, which need to be protected against both cryogenic spills and fire exposure. Oil and gas industry facilities have products of high flammability and explosiveness, which in the case of ignition make it possible to develop a fire along the hydrocarbon curve, accompanied by a sharp jump in temperature and the formation of excessive pressure. This article discusses possible structural fire protection for metal structures in the Arctic region. Three different structural fireproofing materials are presented using super-thin basalt fiber (STBF) as an example. Tests of steel structures with fire protection are demonstrated, as a result of which the time from the beginning of cryogenic exposure to the limit state of samples is determined, and after the time from the beginning of thermal exposure to the limit state of samples under the hydrocarbon temperature regime is determined. An assessment of various flame retardants with values up to 120 min, which can be used in arctic climate conditions, was carried out. It was found that the most effective coatings are materials prepared on the basis of STBF.

27 September 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Ekaterina KirikEkaterina Kirik
Ekaterina Kirik
ABAleksey Bogdanov
Aleksey Bogdanov
OSOlga Владимировна Sushkova
Olga Владимировна Sushkova
Marina Viktorovna GravitMarina Viktorovna Gravit
Marina Viktorovna Gravit
DSDaria Shabunina
Daria Shabunina
YLYuriy Lazarev
Yuriy Lazarev
The manuscript is focused on the problems of evacuation in case of fire from the buildings of museums as places with a mass presence of people. Features specific to museums and how they affect safe evacuation conditions are discussed. Most attention is paid to evacuation management, since the vast majority of museum visitors are not familiar with the layout of the building. In this case, the actions of staff in evacuation management are decisive. The paper considers the development of evacuation schemes, taking into account the spread of fire hazards in the building and the development of instructions on their basis for the staff. Using the example of the Winter Palace of the State Hermitage Museum, the solution of the marked tasks with the use of computer simulation of evacuation during a fire is given. The analysis of the simulation results showed the vulnerabilities of the museum. In this work, the evacuation schemes for the scenarios are considered. The maximum number of visitors at a single time in the Winter Palace has been set at 4000. The principles of making evacuation schemes are formulated, including taking into account the peculiarities of space-planning solutions inherent in museums, such as enfilades and the connections of rooms.