Hamza Landari

Mr. Hamza Landari

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
HLHamza Landari
Hamza Landari
MRMourad ROUDJANE
Mourad ROUDJANE
YMYounès Messaddeq
Younès Messaddeq
AMAmine Miled
Amine Miled
In this paper, we present a new FTIR-based microfluidic system for Glucose, Fructose and Sucrose detection. The proposed microfluidic system is based on a pseudo-continuous flow coupled to a microscope-FTIR instrument. The detection and characterization of sugar samples were performed by recording their absorption spectrum in the wavelength range 700–1000 cm − 1 of the Mid-IR region. The proposed pseudo-continuous flow system is designed to improve the uniformity of the sample distribution in the analyzed area versus conventional systems. The obtained results for different sugars concentrations, show a very low measurement error of 4.35% in the absorption peak intensity, which is ten times lower than the error obtained using the conventional measurements.

28 May 2016 in Sensors
Verified
Journal Article
Open access
PDF file
AKAdnane Kara
Adnane Kara
CRCamille Rouillard
Camille Rouillard
JMJessy Mathault
Jessy Mathault
MBMartin Boisvert
Martin Boisvert
FTFrédéric Tessier
Frédéric Tessier
AMAmine Miled
Amine Miled
In this paper, we present a new modular lab on a chip design for multimodal neurotransmitter (NT) sensing and niosome generation based on a plug-and-play concept. This architecture is a first step toward an automated platform for an automated modulation of neurotransmitter concentration to understand and/or treat neurodegenerative diseases. A modular approach has been adopted in order to handle measurement or drug delivery or both measurement and drug delivery simultaneously. The system is composed of three fully independent modules: three-channel peristaltic micropumping system, a three-channel potentiostat and a multi-unit microfluidic system composed of pseudo-Y and cross-shape channels containing a miniature electrode array. The system was wirelessly controlled by a computer interface. The system is compact, with all the microfluidic and sensing components packaged in a 5 cm × 4 cm × 4 cm box. Applied to serotonin, a linear calibration curve down to 0.125 mM, with a limit of detection of 31 μ M was collected at unfunctionalized electrodes. Added sensitivity and selectivity was achieved by incorporating functionalized electrodes for dopamine sensing. Electrode functionalization was achieved with gold nanoparticles and using DNA and o-phenylene diamine polymer. The as-configured platform is demonstrated as a central component toward an “intelligent” drug delivery system based on a feedback loop to monitor drug delivery.

10 April 2017 in Sensors
Verified
Journal Article
Open access
PDF file
EGElnaz Ghodsevali
Elnaz Ghodsevali
SMSamuel Morneau-Gamache
Samuel Morneau-Gamache
JMJessy Mathault
Jessy Mathault
HLHamza Landari
Hamza Landari
EBElodie Boisselier
Elodie Boisselier
AMAmine Miled
Amine Miled
A novel fully differential difference CMOS potentiostat suitable for neurotransmitter sensing is presented. The described architecture relies on a fully differential difference amplifier (FDDA) circuit to detect a wide range of reduction-oxidation currents, while exhibiting low-power consumption and low-noise operation. This is made possible thanks to the fully differential feature of the FDDA, which allows to increase the source voltage swing without the need for additional dedicated circuitry. The FDDA also reduces the number of amplifiers and passive elements in the potentiostat design, which lowers the overall power consumption and noise. The proposed potentiostat was fabricated in 0.18 µm CMOS, with 1.8 V supply voltage. The device achieved 5 µA sensitivity and 0.99 linearity. The input-referred noise was 6.9 µV rms and the flicker noise was negligible. The total power consumption was under 55 µW. The complete system was assembled on a 20 mm × 20 mm platform that includes the potentiostat chip, the electrode terminals and an instrumentation amplifier for redox current buffering, once converted to a voltage by a series resistor. the chip dimensions were 1 mm × 0.5 mm and the other PCB components were off-chip resistors, capacitors and amplifiers for data acquisition. The system was successfully tested with ferricyanide, a stable electroactive compound, and validated with dopamine, a popular neurotransmitter.

25 August 2021 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
HLHamza Landari
Hamza Landari
YMYounes Messaddeq
Younes Messaddeq
AMAmine Miled
Amine Miled
In this work, we present a new sensing approach for aqueous samples based on the microscope-FTIR spectrometer and applied for neurotransmitters. Our contribution in this work consists of a new sample handling system for the microscope-FTIR spectrometer based on a total reflective mirror, a heated hydrophobic layer for solvent removal/evaporation and sample confinement and a microfluidic system that handles sample injection unlike standard sample handling system which was based only on a total reflective mirror. In addition, another part of our contribution consists of proposing a new algorithm to extract molecular composition of the solution with high estimation ratios and based on the analysis of detected peaks on IR spectra. The data acquired from the microscope-FTIR spectrometer was analyzed by a newly developed algorithm to identify each neurotransmitter in homogeneous and non-homogeneous solutions with high selectivity. We used six neurotransmitter molecules (Dopamine hydrochloride, L-Ascorbic acid, Acetylcholine chloride, y-Aminobutyric, Glycine and L-Glutamic acid). The results obtained based on the algorithm developed showed that, using the new system, the six neurotransmitters can be identified in homogeneous and mixture solutions with an estimation ratio range of 88.8%-100% for Dopamine hydrochloride, 80%-100% for L-Ascorbic acid, 75%-100% for Acetylcholine chloride, 75%-100% for L-Glutamic, 77.7%-100% for y-Aminobutyric and 75%-100% for Glycine.

4 August 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HLHamza Landari
Hamza Landari
JBJean-Christophe Blais
Jean-Christophe Blais
YMYounes Messaddeq
Younes Messaddeq
AMAmine Miled
Amine Miled
In this work, we propose a new multimodal method/platform for continuous maple syrup °Brix monitoring and color grading during the production process. It is based on different detection methods such as electrical impedance, electrochemical sensing and optical sensing. First, using electrochemistry sensing, the results of maximum detected current in obtained Voltammogram with cyclic-voltammetry (CV) analysis and generated currents for chronoamperometry experiments presents a high standard deviation higher than 50%. In addition, we report the impact of the temperatures on previously mentioned sensing techniques. We have observed that electrochemistral sensor with commercial electrodes in our experimental conditions did not provide reliable measurement for maple syrup industrial process for °Brix monitoring. When using electrical impedance sensing method, a polynomial fitting relationship was established between the electrical impedance and °Brix with a high fitting index (R 2 ) of 0.895. Furthermore, an impedance offset must be considered when temperature is changing. Also, an optical sensor was used to detect the maple syrup grade. As the grade depends on the light transmission percentage through a known thickness of solution, a photodiode detector and a LED were used as grade sensor. Many LEDs with different wavelengths (green, yellow, red, blue and infrared) were tested on different maple syrup grades. Obtained results show that green LED is the most suitable one for maple syrup grade detection which can lead to a linear fit with high fitting index (R 2 ) of 0.963 between voltage response of the photodiode detector and the light transmission which is converted to a maple syrup grade.

1 October 2019
Verified
Conference Paper
Closed access
HLHamza Landari
Hamza Landari
AJA. Jobin-Rioux
A. Jobin-Rioux
LDL-C. Desjardins
L-C. Desjardins
YMY. Messaddeq
Y. Messaddeq
EBElodie Boisselier
Elodie Boisselier
AMAmine Miled
Amine Miled
In this work a new protocol based on Spectrophotometry and invertase solution for Sucrose quantification is presented. The invertase molecule is used for releasing Glucose and Fructose from Sucrose molecules in maple syrup. Then, Glucose Oxydase (GO), Glucose Peroxydase (GPO), Phenol-4-sulfonic acid and 4-aminoantipyrine molecules are used as the optical marker for Glucose molecules which will form a colored compound. This coloration is measured using Spectrophotometry technique and then Glucose is quantified. Finally a glucose "standard" curve is established after an optimization process of Trinder solution composition (GO, GPO, 4-aminoantipyrine and phenol-4-sulfonic sodium salt), detection limit of Glucose concentration in the sample, reaction times and the used wavelengths for coloration measurement.