Representative Publications

View All Publications
8 May 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MRMourad ROUDJANE
Mourad ROUDJANE
SBSimon Bellemare-Rousseau
Simon Bellemare-Rousseau
EDEtienne Drouin
Etienne Drouin
BBBenjamin Belanger-Huot
Benjamin Belanger-Huot
MDMarc-Andre Dugas
Marc-Andre Dugas
YMYounes Messaddeq
Younes Messaddeq
In this paper, we present the design and the validation of a new smart textile developed for real time monitoring of human breath. The smart textile is a wearable stretching T-shirt featuring an array of six contactless and non-invasive sensors placed on human’s thoraco-abdominal walls. The wireless sensors communicate quasi-simultaneously the data to a detection base station through Bluetooth protocol. The sensor is composed of a spiral shaped multi-material fiber antenna with a central frequency at 2.4 GHz connected to a compact Bluetooth transmitter. The sensors are integrated on the stretchable T-shirt without compromising the user’s comfort. The sensing mechanism of the system is based on the shift of the central frequency of the spiral fiber antenna induced by the deformation of the thorax and the abdomen during the breath. As a consequence, the breathing pattern is obtained through the received signal strength indicator recorded by a portable detection base station. With the sensor array integrated into a T-shirt, we demonstrate the feasibility assessment for monitoring breathing of seven volunteers in seating and standing positions. Using an array of sensors strategically placed on the T-shirt provides a more reliable approach to detect interpretable breathing patterns by sensing the movement of the abdomen and the thorax at the same time. Using a commercial spirometer as a standard reference, we assessed the validity of breathing parameters (ie; expiration and inspiration times, breathing period, and breathing rate) measured with the T-shirt. Based on Bland-Altman statistical analysis, a good agreement between textile-based sensors and the standard reference was obtained. We were able to show that the smart T-shirt could detect breathing patterns and pauses in breathing, which could be very useful to monitor sleep apnea and clinical monitoring of patients.

25 March 2018 in Sensors
Verified
Journal Article
Open access
PDF file
MRMourad ROUDJANE
Mourad ROUDJANE
SBSimon Bellemare
Simon Bellemare
MKMazen Khalil
Mazen Khalil
SGStepan Gorgutsa
Stepan Gorgutsa
AMAmine Miled
Amine Miled
YMYounes Messaddeq
Younes Messaddeq
In this paper, we present a new mobile wireless communication platform for real-time monitoring of an individual’s breathing rate. The platform takes the form of a wearable stretching T-shirt featuring a sensor and a detection base station. The sensor is formed by a spiral-shaped antenna made from a multi-material fiber connected to a compact transmitter. Based on the resonance frequency of the antenna at approximately 2.4 GHz, the breathing sensor relies on its Bluetooth transmitter. The contactless and non-invasive sensor is designed without compromising the user’s comfort. The sensing mechanism of the system is based on the detection of the signal amplitude transmitted wirelessly by the sensor, which is found to be sensitive to strain. We demonstrate the capability of the platform to detect the breathing rates of four male volunteers who are not in movement. The breathing pattern is obtained through the received signal strength indicator (RSSI) which is filtered and analyzed with home-made algorithms in the portable system. Numerical simulations of human breath are performed to support the experimental detection, and both results are in a good agreement. Slow, fast, regular, irregular, and shallow breathing types are successfully recorded within a frequency interval of 0.16–1.2 Hz, leading to a breathing rate varying from 10 to 72 breaths per minute.

11 October 2018 in Photonics
Verified
Journal Article
Open access
PDF file
MRMourad ROUDJANE
Mourad ROUDJANE
MKMazen Khalil
Mazen Khalil
AMAmine Miled
Amine Miled
YMYounés Messaddeq
Younés Messaddeq
Smart textiles and wearable antennas along with broadband mobile technologies have empowered the wearable sensors for significant impact on the future of digital health care. Despite the recent development in this field, challenges related to lack of accuracy, reliability, user’s comfort, rigid form and challenges in data analysis and interpretation have limited their wide-scale application. Therefore, the necessity of developing a new reliable and user friendly approach to face these problems is more than urgent. In this paper, a new generation of wearable antenna is presented, and its potential use as a contactless and non-invasive sensor for human breath detection is demonstrated. The antenna is made from multimaterial fiber designed for short-range wireless network applications at 2.4 GHz frequency. The used composite metal-glass-polymer fibers permits their integration into a textile without compromising comfort or restricting movement of the user due to their high flexibility, and shield efficiently the antenna from the environmental perturbation. The multimaterial fiber approach provided a good radio-frequency emissive properties, while preserving the mechanical and cosmetic properties of the garments. With a smart textile featuring a spiral shape fiber antenna placed on a human chest, a significant shift of the operating frequency of the antenna was observed during the breathing process. The frequency shift is caused by the deformation of the antenna geometry due to the chest expansion, and to the modification of the dielectric properties of the chest during the breath. We demonstrate experimentally that the standard wireless networks, which measure the received signal strength indicator (RSSI) via standard Bluetooth protocol, can be used to reliably detect human breathing and estimate the breathing rate in real time. The mobile platform takes the form of a wearable stretching T-shirt featuring a sensor and a detection base station. The sensor is formed by a spiral-shaped antenna connected to a compact Bluetooth transmitter. Breathing patterns were recorded in the case of female and male volunteers. Although the chest anatomy of females and males is different compared, the sensor’s flexibility allowed recording successfully a breathing rate of 0.3 Hz for the female and 0.5 Hz for the male, which corresponds to a breathing rate of 21 breaths per minutes (bpm) and 30 bpm, respectively.

4 December 2006 in The Journal of Chemical Physics
Verified
Journal Article
Closed access
MRMourad ROUDJANE
Mourad ROUDJANE
FLFrançoise Launay
Françoise Launay
LTLydia Tchang-Brillet
Lydia Tchang-Brillet
The emission spectrum of the D2 molecule has been studied at high resolution in the vacuum ultraviolet region 78.5–102.7nm. A detailed analysis of the two DΠu1→XΣg+1 and D′Πu−1→XΣg+1 electronic band systems is reported. New and improved values of the level energies of the two upper states have been derived with the help of the program IDEN [V. I. Azarov, Phys. Scr. 44, 528 (1991); 48, 656 (1993)], originally developed for atomic spectral analysis. A detailed comparison is made between the observed energy levels and solutions of coupled equations using the newest ab initio potentials by Wolniewicz and co-workers [J. Chem. Phys. 103, 1792 (1995); 99, 1851 (1993); J. Mol. Spectros. 212, 208 (2002); 220, 45 (2003)] taking into account the nonadiabatic coupling terms for the DΠu1 state with the lowest electronic states BΣu+1, CΠu1, and B′Σu+1. A satisfactory agreement has been found for most of the level energies belonging to the D and D′ states. The remaining differences between observation and theory are probably due to nonadiabatic couplings with other higher electronic states which were neglected in the calculations.

27 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
MAMehran Ahadi
Mehran Ahadi
MRMourad ROUDJANE
Mourad ROUDJANE
MDMarc-André Dugas
Marc-André Dugas
AMAmine Miled
Amine Miled
YMYounès Messaddeq
Younès Messaddeq
A flexible sinusoidal-shaped antenna sensor is introduced in this work, which is a modified half-wave dipole that can be used for strain sensing applications. The presented antenna is an improved extension of the previously introduced antenna sensor for respiration monitoring. The electrical and radiative characteristics of the sinusoidal antenna and the effects of the geometrical factors are studied. An approach is provided for designing the antenna, and equations are introduced to estimate the geometrical parameters based on desired electrical specifications. It is shown that the antenna sensor can be designed to have up to 5.5 times more sensitivity compared to the last generation of the antenna sensor previously introduced for respiration monitoring. The conductive polymer material used to fabricate the new antenna makes it more flexible and durable compared to the previous generation of antenna sensors made of glass-based material. Finally, a reference antenna made of copper and an antenna sensor made of the conductive polymer are fabricated, and their electrical characteristics are analyzed in free space and over the body.

13 October 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
HLHamza Landari
Hamza Landari
MRMourad ROUDJANE
Mourad ROUDJANE
YMYounès Messaddeq
Younès Messaddeq
AMAmine Miled
Amine Miled
In this paper, we present a new FTIR-based microfluidic system for Glucose, Fructose and Sucrose detection. The proposed microfluidic system is based on a pseudo-continuous flow coupled to a microscope-FTIR instrument. The detection and characterization of sugar samples were performed by recording their absorption spectrum in the wavelength range 700–1000 cm − 1 of the Mid-IR region. The proposed pseudo-continuous flow system is designed to improve the uniformity of the sample distribution in the analyzed area versus conventional systems. The obtained results for different sugars concentrations, show a very low measurement error of 4.35% in the absorption peak intensity, which is ten times lower than the error obtained using the conventional measurements.