A methodology is proposed to effectively extract heart rate from bio-radar sensors based on radar technology. Heart and respiration rates are extracted separately by calculating intrinsic mode functions (IMFs) obtained from the empirical mode decomposition (EMD) method applied to the received radar signals. Due to the frequency difference between respiration and heartbeat signals, it is possible to selectively generate respiration harmonics by exploiting the characteristics present in different IMFs. These harmonics are used to eliminate the noise caused by respiratory activity around the heartbeat signal, thereby improving the signal-to-noise ratio of heartbeat detection. In the experiment utilizing the in-house 5.8 GHz continuous wave radar sensor, the proposed technique exhibited an average heart rate extraction accuracy of 97.5% for the stationary subjects at a distance of 1 m, in comparison to the reference electrocardiogram sensor. Compared to the conventional method using only fast Fourier transform and the EMD-based method without respiration harmonic rejection, the proposed technique achieved an average noise suppression of 22.3 dB and 20.3 dB around the heart rate signal, respectively. In addition, the proposed technique demonstrated the potential to mitigate the effects of random body motion noise, achieving an average heart rate accuracy of 92.8% when applied to the walking subject at a speed of 2 km/h.
Vital signal detection using multiple radars is proposed to reduce the signal degradation from a subject’s body movement. The phase variation in the transceiving signals of continuous-wave radar due to respiration and heartbeat is generated by the body surface movement of the organs monitored in the line-of-sight (LOS) of the radar. The body movement signals obtained by two adjacent radars can be assumed to be the same over a certain distance. However, the vital signals are different in each radar, and each radar has a different LOS because of the asymmetric movement of lungs and heart. The proposed method uses two adjacent radars with different LOS to obtain correlated signals that reinforce the difference in the asymmetrical movement of the organs. The correlated signals can improve the signal-to-noise ratio in vital signal detection because of a reduction in the body movement effect. Two radars at different frequencies in the 5.8 GHz band are implemented to reduce direct signal coupling. Measurement results using the radars arranged at angles of 30°, 45°, and 60° showed that the proposed method can detect the vital signals with a mean accuracy of 97.8% for the subject moving at a maximum velocity of 53.4 mm/s.
A detrending technique is proposed for continuous-wave (CW) radar to remove the effects of direct current (DC) offset, including DC drift, which is a very slow noise that appears near DC. DC drift is mainly caused by unwanted vibrations (generated by the radar itself, target objects, or surroundings) or characteristic changes in components in the radar owing to internal heating. It reduces the accuracy of the circle fitting method required for I/Q imbalance calibration and DC offset removal. The proposed technique effectively removes DC drift from the time-domain waveform of the baseband signals obtained for a certain time using polynomial fitting. The accuracy improvement in the circle fitting by the proposed technique using a 5.8 GHz CW radar decreases the error in the displacement measurement and increases the signal-to-noise ratio (SNR) in vital signal detection. The measurement results using a 5.8 GHz radar show that the proposed technique using a fifth-order polynomial fitting decreased the displacement error from 1.34 mm to 0.62 mm on average when the target was at a distance of 1 m. For a subject at a distance of 0.8 m, the measured SNR improved by 7.2 dB for respiration and 6.6 dB for heartbeat.
2 January 2023 in IEEE Microwave and Wireless Technology Letters
A signal preprocessing method is proposed for effectively monitoring heartbeats from signals obtained using a continuous-wave (CW) Doppler radar. The proposed method consists of windowing with a size optimized for heartbeat detection, detrending to minimize the effect of dc drift, and data reconstruction to increase the fast Fourier transform (FFT) resolution. A window size of 3 s effectively extracts the heartbeat alone from the received signals of the CW radar, which comprised respiration, motion, and heartbeat signals. The effect of the low-frequency noise caused by the internal heat generation of hardware components is reduced by the detrending technique, and the low resolution of the FFT, due to a small number of samples, is improved through reconstruction by combining data from three windows. The signal-to-noise ratio of the measured waveform was improved to 5.83 dB using the proposed method in a 5.8-GHz CW radar. For the data acquired for 60 s, the proposed method showed a heartbeat detection accuracy of 95.8% by using a signal processing time 13% lower than that of the conventional method.
9 July 2024 in IEEE Transactions on Instrumentation and Measurement
Remote vital signal detection using Doppler radar is proposed to reduce the measurement errors caused by environmental factors, including the subject’s body movements. The proposed method for remote detection is based on the radar with beam control, which allows for adjusting the antenna’s radiating direction through spatial synthesis of an antenna array. By altering the beam direction, the proposed radar distinguishes between vital signals (respiration and heartbeat) originating from the asymmetrical movements of the human lungs and heart and the noise signals introduced by environmental factors, such as stationary clutters and the subject’s body movements. The respiration and heartbeat are extracted from the raw radar data obtained from each direction with signal processing techniques, including DC offset removal and random movement cancellation, which are based on the relationship of Bessel functions. An additional algorithm for extracting the correlated data from the acquired vital signals and filtering sudden variations significantly enhances detection accuracy in the proposed method. In a practical test scenario, the vital signs of a subject walking at 2 km/h on a treadmill were measured in the surroundings with stationary clutters using the proposed method with a beamswitching 5.8 GHz radar module at a distance of 1 m. The measurement results demonstrated error rates of less than 3 bpm for respiration and 4.2 bpm for heartbeat, compared to reference values obtained from contact-type sensors.
Frequency-modulated continuous wave (FMCW) radar system synchronization using external clock signals can cause repeated Range-Doppler (R-D) map corruption when clock signal asynchronization problems occur between the transmitter and receiver. In this paper, we propose a signal processing method for the reconstruction of the corrupted R-D map owing to the FMCW radar’s asynchronization. After calculating the image entropy for each R-D map, the corrupted ones are extracted and reconstructed using the normal R-D maps acquired before and after the individual maps. To verify the effectiveness of the proposed method, three target detection experiments were conducted: a human target detection in an indoor environment and a wide place and a moving bike-rider target detection in an outdoor environment. The corrupted R-D map sequence of observed targets in each case was reconstructed properly and showed the validity by comparing the map-by-map range and speed changes in the detected target with the ground-truth information of the target.
About Me
I research on vital signal measurement using continous wave radar.
I research on vital signal measurement using continous wave radar.