Geon-Haeng Lee

Mr. Geon-Haeng Lee

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JPJoo-Eun Park
Joo-Eun Park
GLGeon-Haeng Lee
Geon-Haeng Lee
ILIn-Seong Lee
In-Seong Lee
Jong-Ryul YangJong-Ryul Yang
Jong-Ryul Yang
A methodology is proposed to effectively extract heart rate from bio-radar sensors based on radar technology. Heart and respiration rates are extracted separately by calculating intrinsic mode functions (IMFs) obtained from the empirical mode decomposition (EMD) method applied to the received radar signals. Due to the frequency difference between respiration and heartbeat signals, it is possible to selectively generate respiration harmonics by exploiting the characteristics present in different IMFs. These harmonics are used to eliminate the noise caused by respiratory activity around the heartbeat signal, thereby improving the signal-to-noise ratio of heartbeat detection. In the experiment utilizing the in-house 5.8 GHz continuous wave radar sensor, the proposed technique exhibited an average heart rate extraction accuracy of 97.5% for the stationary subjects at a distance of 1 m, in comparison to the reference electrocardiogram sensor. Compared to the conventional method using only fast Fourier transform and the EMD-based method without respiration harmonic rejection, the proposed technique achieved an average noise suppression of 22.3 dB and 20.3 dB around the heart rate signal, respectively. In addition, the proposed technique demonstrated the potential to mitigate the effects of random body motion noise, achieving an average heart rate accuracy of 92.8% when applied to the walking subject at a speed of 2 km/h.

28 March 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MKMin-Seok Kwon
Min-Seok Kwon
YPYuna Park
Yuna Park
JPJoo-Eun Park
Joo-Eun Park
GLGeon-Haeng Lee
Geon-Haeng Lee
SJSang-Hoon Jeon
Sang-Hoon Jeon
Jong-Ryul YangJong-Ryul Yang
Jong-Ryul Yang
Continuous-wave (CW) radar sensors can remotely measure respiration and heartbeat by detecting the periodic movements of internal organs. However, external disturbances, such as random body motion (RBM) or environmental interference, significantly degrade the signal-to-noise ratio (SNR) and reduce the accuracy of vital sign detection. The various motion cancellation techniques that have been proposed to enhance robustness against RBMs include improvements in radar architecture, advanced signal processing algorithms, and studies on electromagnetic propagation characteristics. This paper provides a comprehensive review of recent advancements in motion cancellation techniques for CW radar-based vital sign detectors and discusses future research directions to improve detection performance in dynamic environments.

4 December 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JPJoo-Eun Park
Joo-Eun Park
GLGeon-Haeng Lee
Geon-Haeng Lee
YPYuna Park
Yuna Park
JPJoon-Young Park
Joon-Young Park
SJSang-Hoon Jeon
Sang-Hoon Jeon
Jong-Ryul YangJong-Ryul Yang
Jong-Ryul Yang
An adaptive algorithm is proposed for selecting the decomposition level of intrinsic mode functions (IMFs) that contain vital signals in a non-contact bio-radar sensing system. Mode decomposition techniques are widely employed to filter out high-frequency noise from radar signals, enabling effective extraction of respiratory and cardiac components. However, the IMF levels containing critical biological information vary due to environmental noise and individual subject differences. The proposed algorithm accurately identifies the appropriate IMF levels for respiratory and cardiac signals without requiring prior knowledge of the input signal. Specifically, it effectively distinguishes vital signs from unwanted noise components, such as respiratory harmonics, that may overlap in frequency bands. This is achieved by estimating significant frequency ranges within each IMF based on analysis of their phase spectrum characteristics. Additionally, the algorithm analyzes offset patterns in the phase components to determine precise frequency boundaries and selects relevant IMF levels accordingly. Experimental evaluations conducted with continuous measurement data from an in-house 5.8-GHz bio-radar sensor demonstrate that the proposed method flexibly adapts to changing IMF levels corresponding to respiratory and cardiac signal. Compared to conventional signal-to-noise ratio-based IMF selection methods, the proposed algorithm reduces the average root mean square error for respiratory rate and heart rate measurements by 9.3 bpm and 3.5 bpm, respectively. This corresponds to improvements in measurement accuracy of 3.3% for respiration and 11.6% for heart rate.

31 May 2026 in The Journal of Korean Institute of Electromagnetic Engineering and Science
Verified
Journal Article
Open access
PDF file
JPJoo-Eun Park
Joo-Eun Park
GLGeon-Haeng Lee
Geon-Haeng Lee
YPYuna Park
Yuna Park
JPJoon-Young Park
Joon-Young Park
Jong-Ryul YangJong-Ryul Yang
Jong-Ryul Yang
한국전자파학회논문지 (The Journal of Korean Institute of Electromagnetic Engineering and Science)

12 March 2026 in IEEE Sensors Journal
Verified
Journal Article
Closed access
GLGeon-Haeng Lee
Geon-Haeng Lee
JPJoo-Eun Park
Joo-Eun Park
YPYuna Park
Yuna Park
JPJoon-Young Park
Joon-Young Park
Jong-Ryul YangJong-Ryul Yang
Jong-Ryul Yang
Falls are a major cause of accidental death and serious injury, particularly among the elderly. While various detection systems exist, wearable devices often suffer from low compliance, and vision-based methods raise significant privacy concerns. To address these issues, a radar-based fall detection system is proposed, which exploits free-fall signatures observed in both the time and frequency domains through a stepwise analysis. To isolate the rapid Doppler shifts characteristic of fall events, empirical mode decomposition (EMD) is applied to extract high-frequency components from the first intrinsic mode function (IMF1). Unlike voluntary daily movements that exhibit consistent and bounded frequency patterns, falls are involuntary and involve sudden free-fall motion, resulting in elevated power spectral density (PSD) in higher-frequency bands that are rarely observed in ordinary activities. The proposed algorithm identifies fall events by measuring the PSD from IMF1 in the band above 50 Hz and discriminating them from non-fall motions. Experimental validation using an in-house 5.8-GHz continuous-wave radar shows that fall events exhibit, on average, a PSD increase of about 17.5 dB compared with typical daily activities. A total of more than 1,000 experimental trials were conducted with five volunteers possessing diverse physical profiles (height: 158–180 cm, weight: 50–93 kg), verifying the reliability of the proposed system and demonstrating its robustness across different body characteristics.