This research explores how climate change will affect building energy use across the UK by analysing both a conventional reference building design and a net-zero energy (NZEBs) alternative to assess how each would perform under future weather conditions. Using climate projections from databases like Prometheus and Meteonorm, along with simulation tools like EnergyPlus and Freds4Buildings, the study evaluates the energy performance, costs, and GHG emissions of a case study building under current weather conditions, with 2030, 2050, and 2080 forecasts in three different UK locations: Exeter, Manchester, and Aberdeen. Results indicate that heating demand will decrease consistently over time across all locations by as much as 21% by 2080 while cooling demand will rise sharply. NZEBs proved more resilient to these changes, using less energy and producing fewer GHG emissions than conventional buildings, with 89% reductions in emissions even with increased cooling needs. Accounting for future weather helps both understand the risks of conventional design, with a number of scenarios experiencing overheating in 2080 and ensure NZEBs can meet their goals during their entire lifespan despite the increases in energy needs. The study highlights both the impact of accounting for future weather forecasts during design and the increasing relevance of net-zero energy designs in mitigating the effects of climate change while offering practical insights for architects, policymakers, and energy planners, showing why future weather patterns need to be considered in sustainable building design to ensure buildings will achieve their carbon targets throughout their life.
Regarded as important cultural heritage, historic churches have been utilised over hundreds of years for worship and community benefit. Simple on/off space heating systems are installed in many churches to increase human comfort. However, the conservation of the important historic artefacts and artwork contained within may not have been fully considered. This review attempts to appraise the standards in place for artefacts and artwork. A consensus of 15–25 °C and 40–65% relative humidity is established as safe from the standards reviewed. Consideration is given to the environment within the church to understand if such exacting conditions can be met. The review finds that the conservation and preservation of artefacts and buildings are aligned goals, although striving to meet specified target ranges for artefact types is not fully compatible with historic churches. The stability of the internal environment is clearly an important factor in conservation and benefits human comfort expectations. Churches may contain microclimates throughout the building, complicating the use of target ranges for artefacts, artwork and comfort. The findings of this study can assist historic churches in managing the change, alteration or installation of heating systems.